Tender For special Repair To Bldg No T-140 (War Maintenance & Disaster Med/Surg Brick) At Afmsd, Provn Of Fresh Air Fan For Md Accn Qtrs At Old Chitral Line And New Chitral Line Under Ge (West) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · Delhi, Delhi
Tender Value
48.94 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
0 days left
EMD
97880
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Bldg No T-140 (War Maintenance & Disaster Med/Surg Brick) At Afmsd, Provn Of Fresh Air Fan For Md Accn Qtrs At Old Chitral Line And New Chitral Line Under Ge (West) Delhi Cantt-10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Jun-2026 Revised BOQ BOQ 09-Jul-2026

BOQ

Name of Work:- SPL REPAIR TO BLDG NO T-140 (WAR MAINT & DISASTER MED/SURG BRICK) AT AFMSD, PROVN OF FRESH AIR FAN FOR MD ACCN QTRS AT OLD CHITRAL LINE AND NEW CHITRAL LINE UNDER GE (WEST) DELHI CANTT-10
Sl. No. Item Description
1Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
2S&F Pre-painted galvalume aluminium zinc coating (AZ 150 gsm) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
3S&F Pre-painted galvalume aluminium zinc coating (AZ 150 gsm) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge,roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
4Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
5Providing & fixing Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified as per directions of the Engineer-in Charge.
6S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
7M&L for exposed 8mm thick metal frame designer ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed.
8Dismantling wooden scantling work framed truss etc complete all as specified and directed.
9S&F mild steel rolled work as in roof trusses, (framed),trussed,purlin,crane gantries,rails and heavy bracket framing (Beam,angle,channel or flat section) including distance pieces,cleats etc,confirming to gradeFe 410 -W (GdeE- 250) quality-A, complete all as specified and directed.
10Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
11S&F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks, wind tie and similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x15mm in CM 1:2:4 (using 20mm graded agg complete all as specified and directed. .
12M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over and incld a coat of red oxide primer.complete all as specified and directed.
13Taking down Chowkats or frames n.exc 1.5 sqm each with shutters (without taking off shutters from the frames).complete all as specified and directed.
14Taking down Chowkats or frames exc 1.5 sqm but n.exc 4 sqm each with shutters (without taking off shutters from the frames).complete all as specified and directed.
15S&F 4 mm thick figured glass/ pin head type and glazing in squares not exc 0.5 Sqn in each pane complete all as specified and directed.
16M&L PCC 1:3:6 type C1 (20mm gr agg) as in anchoring hold fast, bed plate etc all as specified and directed.
17Taking down cement plaster from stone/brick walls including racking out joints for keys and scrubbing down with water etc, complete all as specified and directed.
18Material and labour for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement; 4 coarse sand)(sand source - Badarpur only) furrowing the under layer with scatching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 white cement: 1/2 marble dust : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings incl nailing with 75 mm MS nails @ 450 mm both ways on wall surface complete all as specified complete incl taking down old plaster as per specifications and direction of the Engineer-in-charge.
19M&L for forming groove (area of each panel not exceeding 2 sqm each) of size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed.
20M&L for 10mm thick rendering of ready mix mortar of approved make on brick work or concrete surfaces on external walls, finish the surface even and smooth without using extra cement as whole or in patch etc complete all as specified and directed.
21M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over and incld a coat of alkali primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
22Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as sfd and directed.
23M&L for Brick work with Sub class 'B' old size burnt bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
24Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
25Demolition of cement concrete in ground floor and paving n.exc 15CM thickness (below or above ground level) complete all as specified & directed.
26M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2(using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site. complete all as specified and directed.
27M&L PCC 1:3:6 type D2 using 40 mm graded stone aggregate as in foundation filing and mass concrete. complete all as specified and directed.
28Dismantling of stone slab/paving tiles laid, bedded and pointed in any mortar of any description or thickness in floors. complete all as specified and directed.
29M&LProviding and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed.
30M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and incld 15mm thick cement screed base in CM 1:4 complete all as spd & directed.
31M&L Machine cut kota stone slab 20-25 mm thick as in vertical surfaces such as riser of steps, skirting, dado and pillar etc., laid over and incl 10 mm thick backing coat in CM 1:3 set and jointed in neat cement slurry and pinted with cement and pigment to match the shade of the slab incl rubbing and polishing etc., complete all as specified and as directed.
32M&L endura parking tiles of size 30cm x 30cm x10-12mm thick colored, with cement and pigment and point in neat cement slurry in floors and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
33M&L 2 mm thick mild steel, plain, sheet inwall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to concrete or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required as in repairs complete all as specified and directed.
34S&F Steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glasing bars, devetailed or welded complete all as specified and directed.
35S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50sqm each.all as specified and directed.
36M&L post construction ATT treating the top surface of filled earth at the rate of 5 litres of emulsion per sqm of surface area complete all as specified and directed.
37M&L ploviding and injectiong chemical emulsion for post construction anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. complete all as specified and directed.
38M&L Cement concrete 1:2:4 type B1using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed .
39M&L for concealed point wiring with PVC insulated sheathed multistranded colour code copper conductor in PVC conduit with FRLS cable1.5 Sqmm size 1100 volts grade conforming to IS:694 in box of 1.6 mm thick including one coat of synthetic enmelled black paint and providing with brass screws and cup washers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit all as specified and directed by Engr-in-charge for the following :-
40One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specified and directed.
41S&F of switch piano flush type type 6 amps single pole one way complete all as specified and directed.
42S&F of fresh Air Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200/250 mm sweep, single phase, complete all as specified and directed.
43Cutting and making proper smooth round/square holes in wall/windows suitable for fixing of fresh air fan 250/300 mm sweep dia and finishing the wall surface as per existing treatment complete all as specified and directed.
44S&F of ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
45Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed.
46Material & Labour for point wiring with 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 1.5 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge at site for the following :-
47One light/fan/bell point controlled by one way switch 5 amps. complete all as specified and directed.
48One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. complete all as specified and directed.
49One 3 pin 5 Amps socket outlet point controlled by one way switch on same board. complete all as specified and directed.
50All as per above item No 48 but with cable 2.5 Sqmm size 1100 volts grade for One 3 Pin socket 15A Independent board complete all as specified and directed.
51Material & Labour for point wiring with 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable conforming to IS 694:2010 with and including continuous earth wire of size 4.0 sqmm (nominal size) single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353:1985 drawn through an including concealed medium grade, PVC conduit of 20 mm dia (Nominal bore) or higher, minimum wall thickness 1.6 mm conforming to IS 9537(Part 3):1983 for conduits complete with and including all conduit accessories (conforming to IS 3419:1988 for conduit accessories) and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM conforming to IS 14772:2000 having bottom, side and back-wall knockouts for conduit entry from any direction for one 3 pin AC Box outlet 20 Amps concealed and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732:2019 and directed by Engr-in-Charge. (For AC point)
52S&F Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed.
53S&F Modular switch 1 way 16A,1 module, 230V, 50 Hz complete all as specified and directed.
54S&F Modular socket 6A- 3 pin combined 2 module,230V, 50 Hz complete all as specified and directed.
55S&F Modular socket 6A/16A - 2/3 pin combined 2 module, 230V, 50 Hz complete all as specified and directed.
56Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated, FRLSH, unsheathed cables of 1100 Volts grade conforming to IS 694:2010 complete including taking down existing old wire all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length.
57Taking down of Ceiling fan, Ceiling cable end, dismantling blades and removing fan and blades and deposit to the MES store yard complete all as specified and directed.
58S & F 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor copper wound, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.50, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS 374:2019), THD less than 10%, remote unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete. complete all as specified and directed.
59S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43, IK 9 protection) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IEC 61439-3 including taking down old DBs all as specified and directed.NOTE :-(a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
60S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 & IK 9 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for 100 Amps, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings including blank spacer for blank space complete all as specified and conforming to IEC 61439-3 including taking down old DBs all as specified.NOTE :-(a) MCBs/MCCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. complete all as specified and directed.
61S&F of MCCB 100 Amp, 4 pole, 16 KA breaking capacity at 415 V, 50 Hz conforming to IEC 60947-2 with fixed thermal magnetic release complete all as specified directed.
62S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity conforming to IEC 60898-1:2002 complete all as specified and directed.
63S&F of SPN MCB 32 Amps, 240V, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10KA breaking capacity conforming to IEC 60898-1:2002 complete all as specified and directed.
64S&F surface/wall mounting LED batten luminaire with following specifications :-(a) System Power : 20 W(b) Length : 4ft(c) Housing : Epoxy powder coated white extruded aluminium channel(d) Diffuser : Milky White Polycarbonate(e) Rated Voltage : 240V(f) Safe Operating Voltage : 140V to 270V(g) Rated Frequency : 50Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 45 deg C(l) Lumen Efficacy of LED : ≥ 120 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CRI : ≥ 80(o) CCT : 5700K(p) Driver : Integral SMPS based constant current type with short circuit, surge voltage protection upto 2.5 KV.(q) IP rating : 20(r) IK rating : 03(s) Average LED life : 50000 Hrs, complete all as specified and directed.
65S&F in replacement LED Building security light fitting complete with mounting bracket made out of light grade GI pipe 40mm bore 1.20 mtr long bend to shape including 02 Nos of 40x5mm FI clamps with GI bolt, nut, washer and 3-core copper cable connection from ceiling rose to light fitting. Specification of light fitting are as under :-(a) System Power : 35 W(b) Housing : Pressure die cast aluminium alloy having separate optical & control gear compartment, top opening, polyster powder coated after phosphochromate treatment(c) Optics : Polycarbonate UV stabilised with integrated lens(d) Light source : SMD LED module mounted on MCPCB(e) Rated Voltage : 240V(f) Safe Operating Voltage : 140V to 270V(g) Rated Frequency : 50Hz(h) Power Factor : ≥ 0.95(j) THD : ≤ 10(k) Operating Temp : - 10 deg C to + 50 deg C(l) Lumen Efficacy of LED : ≥ 140 Lm/W(m) System Luminous Efficacy : ≥ 100 Lm/W(n) CCT : 5700K(o) Driver : In built SMPS based constant current type with protection for output open /short circuit, phase to phase, over voltage & surge voltage upto 10 KV.(p) IP rating : 66(q) IK rating : 07 , complete all as specified and directed.
66S&F in repair of flat panel light aesthetically designed (2ft x2ft) LED flat panel for surface/recessed mounting type which provides soft-light and glare free symmetrical illumination 35/36 Watt fixture should have minimum system luminous efficacy 110 lumen/W, Power Factor ≥ 0.95, Rated Frequency-50Hz, CCT:5700K-6500K, Safe Operating Voltage - 140V to 270V, operating Temp : - 10 deg C to + 45 deg, CRI ≥ 80,THD ≤ 10, IP-20 & IK 3 protection with impact and corrosion resistant complete all as specified and directed.
67S&F of single pole MCB 40 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity conforming to IEC 60898-1:2002 complete all as specified and directed.
68S&F of single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
69S&F exhaust fan, steel body AC single phase. 230 V of size 450mm sweep heavy duty with blades and frame and stainless steel louvers complete and making opening for fixing of exhaust fan in round/square shape all as specified and directed.
70M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1 chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed at site. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56044524
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.94 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Bldg No T-140 (War Maintenance & Disaster Med/Surg Brick) At Afmsd, Provn Of Fresh Air Fan For Md Accn Qtrs At Old Chitral Line And New Chitral Line Under Ge (West) Delhi Cantt-10
Basic Detail
Tender No GE/DW/TOKEN/50 OF 26-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 23 Jun 2026
Submission Date 09 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 48.94 Lakhs
Tender Fee 500
EMD 97880
Exemption Available
Document List
9e9bb785-486d-4a28-b0a9-b06b2ce3867b.html
BOQ_865623.xls
ps50.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.