| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil all as specified and directed.Note:-Ensurance of workmen & cleaning of site, removal of all hinderance's/obstractions unforseen item, Electric cable, Gas Pipe line etc permisssion from other department should be responsibility of contractor (MES will only assist in getting permission etc) restoring and getting the same constructed/Repaired/Replacement complete & nothing extra shall be payable. |
| 2 | M&L for plain Cement concrete in surface channels and drains type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and directed. |
| 3 | M&L for burnt old size brick work with sub class 'B' bricks straight or curved on plan built in CM 1:4 complete all as specified and directed. |
| 4 | M & L 50 mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in bed plates, coping and like plastering on all exposed surface of concerete , incl form work all as complete all as specified and directed. |
| 5 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed |
| 6 | M&L 15mm thick rendering with ready mix mortar of approved make on wall surface finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | Returning, filling in soft loose soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 8 | Removing excavated material soil n exc. 50m and depositing where directed at a level n exc. 1.5 m complete all as specified and as directed. |
| 9 | M&L for cutting of road as required for laying RCC pipe line including repair/make good with filling of earth, boulders, WBM, BM etc. with top surface finished with 30mm thick ready mixed patch filter, complete all as specified and as directed. |
| 10 | S&F 300 mm dia reinforced concrete pipes, class NP2 with collar per length of pipe laid in trenches complete all specified and directed. |
| 11 | M&L for PCC 1:4:8 type D-2 (40mm gde stone agg) as in concrete bed to RCC drain pipes including packing under and hunching against side of pipes with concrete after they are laid and join ted, dia of pipe 300mm complete as specified and directed by Engr-in-Charge. |
| 12 | S&F for Precast 75mm thick SFRC manhole/drain covers of size exc 0.30sqm but not exc 0.90 sqm each set and jointed in cement mortar 1:4 complete all as specified and directed |
| 13 | S&F 30mm to 50mm thick precast fibre reinforced cement concrete drain/Manhole cover with holes including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty size exc 0.30sqm but not exc 0.90 sqm each complete all as specified and directed. |
| 14 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for RCC (Designl mix) M-25 (20mm graded aggregate) as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for RCC (Design mix) M-25 (20mm graded aggregate) as in columns, pillars,piers,posts and struts etc complete all as specified and directed. |
| 17 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in beams, cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for RCC(Design mix) M-25 (20mm graded aggregate) as in Chhaja complete all as specified and directed by Engr-in-Charge. |
| 20 | Use & waste of formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits if any of foundations and plinth beams and similar work,vertical or batter for flat rough finished surface of concrete complete all as specified and directed by Engr-in-Charge. |
| 21 | Use & waste of formwork to sides of pillars,posts,struts,piers,columns and stanchions etc rough finished for square/rectangular or polygonal surfaces of concrete complete all as specified and directed by Engr-in-Charge. |
| 22 | Use & waste of formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished flat surfaces of concrete all as specified and directed |
| 23 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough flat finished surfaces of concrete complete all as specified and directed. |
| 24 | M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. |
| 25 | M&L of TMT bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 26 | Ditto all as per item No 25 above but 5 mm dia and over upto and including 10 mm dia in stirrups spaces and binders complete all as specified and directed. |
| 27 | M&L for old size burnt Brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 28 | All as per Serl Item No 27 here in before but half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 29 | M&L for 15mm thick cement plaster in cement mortar 1:4 on brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for 10mm thick cement plaster in cement mortar 1:6 on brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 31 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge. |
| 32 | M&L Two coat of water based exterior acrylic emulsion in camouflaging (in multi colour pattern shall be approved by GE) after applying a coat of exterior (water based) primer on plastered surfaces, including preparation of surfaces complete all as specified and as direcetd |
| 33 | M&L for Preparation of new plastered surfaces wall and ceiling applying birla white putty 1mm on wall even and smooth surfaces and applying two coat of oil bound distemper over a coat of alkali primer (of approved quality and tint) on wall using painting roller complete all as specified and directed. |
| 34 | M&L for Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 35 | M&L for hard core of broken stone or boulders gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and ramed to a true surface complete all as specified and directed. |
| 36 | M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bedding 15mm thick in cm(1:6) complete all as specified and directed. |
| 38 | M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces such as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including provision of backing coat 10mm thick in CM (1:4) complete all as specified and as directed. |
| 39 | M&L for applying two coat of Bitumen primer blown any grade, applied hot, to concrete surfaces at the rate of 1.5kg. per sq. m per coat APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 40 | M&L for 10mm thick screed plaster on roof for laying in CM 1:4 waterproofing treatment with using WPC (WPC will be measured and paid separately as supply only) complete all as specified and directed. |
| 41 | Supply only integral Waterproofing compound.complete all as specified and directed. |
| 42 | M&L powder coated aluminium 50 micron anodised three way track sliding windows of frame size 92 mm x 31.75 mm x 1.5 mm thickness weight of 1.07 Kg/m and of shutter size 40mm x 18 (with 9.00 mm interlocking legs) x 1.45 mm thick section, including 95mm aluminium handle with spring lock, stainless steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with steel wire stapples 5mm thick plain glass including necessary fitting/fixture/aluminium snap beads complete all as specified. (Note : Measurement shall be taken clear opening ie out to out of window frame as a whole including all fittings and fixtures and no extra shall be paid separately. Cost of glass and wire cloth included herein complete all as specified and directed.) |
| 43 | M&L for powder coated aluminium grill of powder coating of minimum 50 micron with aluminium mesh of size 50 mm x 50mm with square tube solid 6mm thick including aluminium channel of suitable size thickness of channel 1.5mm complete all as specified and directed at site. |
| 44 | M&L for false ceiling with 600mmx600mmx4mm thick 'E' board classic of M/S Eternit Everest Ltd or Charminar make as approved by GE, fixed with and including galvanized iron powder coated inverted 'Tee\\" or 'L' sections (concealed GI/aluminium frame work) of 'Cicage' metallic or equivalent suspended from ceiling with provision of galvanized iron wire 45 mm dia and self tapping screws including butterfly clips, hold down clips for fixing the boards to frame complete all as pe manufacturer's instructions and all as directed including demolition of old ceiling.(a) Size of Main Tee- 39x24.7x0.8mm(b) Size of Cross Tee- 29x24.7x0.8mm(c) Size of wall angle - 22.2x22.2x0.65mm(d) Butter fly clip(e) Hold down clip(f) Size of grid 1.22mx0.61m complete all as specified and directed. |
| 45 | S & F for 5mm thick Prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing including 5 mm thick PVC sheet fillet of width 35 mm thick wall paneling incl of fixing on to shelter make PVC frame at site incl necessary fillets fixed etc including demolition of old wall paneling complete all as specified and as directed. |
| 46 | S&F Aluminium door single leaf with powder coated aluminium frame of section 62.5x37x1.5mm thick, shutter with bottom & middle rail of section 112.50x 37x1.5mm thick and styles & top rail of section 83x37x1.5mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5mm thick frosted glass including necessary fittings, fixtures & aluminium snap beads, complete all as specified and directed. |
| 47 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. removal of rubbish beyond MoD land complete all as specified and as directed. |
| 48 | M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed. |
| 49 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including demolition of old paver block complete all as specified and as directed. |
| 50 | Demolition of reinforced cement concrete as in roofs, floors(other than ground floor), beams, staircases, landing, chajjas and similar suspended works. complete all as specified and directed. |
| 51 | M&L for Preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting primer complete all as specified and directed. |
| 52 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft loose soil complete all as specified and as directed. |
| 53 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 54 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in sub base flooring complete all as specified and as directed. |
| 55 | S&F PVC insulation panels Thickness of PVC insulation panel 10mm with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling including grid made of Aluminium complete all as specified and as directed by engr in charge |
| 56 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified |
| 57 | S&F rolled mild steel work in Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 58 | S&F of Fe 410-W(Gde-E-250) quality-A mild steel plates, plain or chequered , 5mm thick or over in thickness in available sizes complete all as specified & directed. |
| 59 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long diameter of neck 11 to 15mm complete all as specified and as directed. |
| 60 | S&F pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50 mm thick 150 GSM of any colour as approved by GE having tensile strength of 550Mpa as in roof covering, ridge, fixed with self tapping screws complete all as spd & directed. |
| 61 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick 150 GSM of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 62 | Designing providing and fixing 4mm thick Aluminium composite cladding over RCC/BRICK/steel surfaces either segmental/straight in plan wherever specified with extruded aluminium u sections ,angles,cleats ,weather sealants, backer rods of required size stainless steel screws, rivets , brackets, drilling and fixing the cladding to either masonary or reinforced cement concrete including frame work as required and as per manufacturer's instructions, complete the work in all respect including all necessary accessories. At all soffits aluminium cladding shall be bend 90 degree and joints at corner or edges will not be acceptable on horizontal surface, the size also converted the shape in awning to the face as approved desiged complete all as per manufacturer's specifications and as directed. |
| 63 | M&L for preparation of new steel & iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as spd & directed. |
| 64 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. |
| 65 | M&L for concealed point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated single core copper cable FRLS as earth continuity conductor, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing modular switches, socket outlet and fan regulators etc. all as specified and directed :- |
| 66 | (a) One light/ fan/ bell/ Exhaust fan/ Fresh Air Fan point controlled by one way switch 5 amps. complete all as specified and directed. |
| 67 | (b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. complete all as specified and directed. |
| 68 | (c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board along with other switches. complete all as specified and directed. |
| 69 | All as per item No 67 above but with single core copper conductor cable FLRS 2.50 sqmm for one 3 pin AC Box outlet,20 Amps concealed and including provision of 2.50 Sqmm PVC insulated single core copper conductor cable as earth continuity conductor on independent board.complete all as specified and directed. |
| 70 | M&L for concealed point wiring with insulated unsheathed multistranded FRLS copper conductor in non-metalic rigid PVC conduit but with single core copper conductor cable FLRS 4.0 sqmm for one 3 pin AC Box outlet 20 Amps concealed and including provision of 4.0 Sqmm single core PVC insulated copper conductor cable as earth continuity conductor on independent board.(For AC point) complete all as specified and directed. |
| 71 | S&F Modular switch 1 way 6A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 72 | S&F Modular switch 1 way 16A,1 module, 230V, 50 Hz complete all as specified and directed. |
| 73 | S&F Modular socket 6A- 3 pin combined 2 module,230V, 50 Hz complete all as specified and directed. |
| 74 | S&F Modular socket 6A/16A - 2/3 pin combined 2 module, 230V, 50 Hz complete all as specified and directed. |
| 75 | S&F Modular ceiling fan regulator, step type for BLDC ceiling fan 1 or 2 module. complete all as specified and directed. |
| 76 | S&F of switch modular type single pole Bell push 6 Amp 1 module complete all as specified and directed. |
| 77 | S&F of electric Bell ding dong AC 230 volts single pole all as specified and directed. |
| 78 | S&F ceiling fans complete with blades, down rod, regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 79 | Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the disturbed surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking down existing old wire all as specified and directed. Note :- Two runs of IC x 6.00 sqmm (Phase wire and neutral ) and one run of IC x 6.00 sqmm (as earth wire) will be measured as one unit length. |
| 80 | S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 10 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 all as specified and directed. NOTE:- (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 81 | S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and directed. |
| 82 | S&F in replacement MCB SPN 40 Amps rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 83 | S&F in repair surface mounting LED Batten Warm white 20 W LED light . Fixture should have minimum efficacy at system level >=100 lumens/Watt, life of fixture not less than 50K hrs, CCT 4000-6500K & CRI>80, PF≥0.90. An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 84 | S&F of 35 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 85 | M&L for Decorative wall light fitting made up of polycarbonate, B-22 complete all as specified and directed. |
| 86 | S&F LED Lamp Warm white 09 Watt, 90 lm/W, with PF >0.9 & CRI:80,protection againt high voltage upto 360 V, B22 ,230 Volts,50 Hz,6500K complete all as specified and directed. |
| 87 | S&F of 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP 65 Protection, System level efficacy of the Luminary is =>90 lm/W, Power Factor =>0.90, Colour Temperature 3000K-6500K, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 88 | S&F of ceiling rose 3 phase/PVC/ polycarbonate isolated body complete all as specified and directed. |
| 89 | M&L for modular AC Box with 20A SP mini MCB, plastic enclosure & unbreakable Heavy Duty ISI mark Plug top complete for AC point set dully concealed in wall complete all as specified and directed. |
| 90 | M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1 chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed at site. Please Enable Macros to View BoQ information |