| 1 | Taking down Chowkats or frame exc 1.5 SqM but n.exe 4 Sqm each without taking off shutters from the frame complete all as specified and as directed. |
| 2 | S&F 1.25mm thick pressed steel framed for door with one or more rebates including necessary fixing lugs, hinges, lock strike plates, size of frame 125 X 60 mm including one shop coat of primer complete all as specified and as directed. |
| 3 | M & L providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and as directed. |
| 4 | S&F of 30mm thick hard wood factory made, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 5 | S&F 150mm aluminium handles cast type anodised complete all as specified and as directed. |
| 6 | S & F 150 mm long Mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and as directed. |
| 7 | S&F 250mm long Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed. |
| 8 | S&F in repair steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or without glazing bars complete all as specified and as directed. |
| 9 | M&L preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 10 | Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed. |
| 11 | S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed. |
| 12 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed. |
| 13 | M&L brick works with fly ash bricks as in channel, straight or curved on plain exc mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 14 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 complete all as specified and as directed. |
| 15 | All as per item No 14 above but Brick but except brick (serviceable brick obtained from item no 12 have-in-before shall be reused) complete all as specified and as directed. |
| 16 | Taking down cement plaster on wall of any desription including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 17 | M&L rendering 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 5mm) mixed with liquid water proofing compound in top layer as per manufacturer's instructions, finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured & paid separtely. |
| 18 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed |
| 19 | M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 20 | M&L for rendering 5mm thick plastering in CM (1:3) on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement. |
| 21 | M&L preparation of newly plastered surfaces on wall / ceiling / chajjas and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Ltre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces as per the manufacturer instruction complete all as specified and as directed. |
| 22 | M&L preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery, electrical fittings, wiring etc. of drops and splashes complete all as specified and as directed. |
| 23 | M&L preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified and directed. |
| 24 | M&L complete removal of existing finishes from wall surfaces and applying two coats of 1st quality acrylic distemper (ready mix) having voc content less than 50 gms/litre of approved manufraturer of required shade and colour over a coat of primer including necessary preperation of surfaces complete all as specified and directed. |
| 25 | M&L for preparartion of old surfaces applying two coats of white washing on ceiling surface complete all as specified and as directed. |
| 26 | M&L complete removal of existing treatment of old decorated treatment on wall / ceiling / chajjas by scrapping with true care wall sander ( having mechanical vacuum mechanism ) having RPM not less than 1500, sanding pad of 80 grit having dia 7\\"/9\\" to make the surface free from dust, loose paints etc. or equivalent makes viz Xpress sanding machine having sanction vacuum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc complete and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces as per the manufacturer instruction complete all as specified and as directed. |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises including taking down cement plaster complete all as specified and as directed. |
| 28 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including cement screed bed / backing layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.Note:- Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 29 | S&F coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick seved bed or beddy layer in cement mortar 1:6 as in floor complete all as specified and as directed |
| 30 | M & L glazed ceramic colour tiles 300X 450 X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile including 10mm thick beddy layer in cement mortar 1:4 complete all as specified and directed. |
| 31 | M & L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms,corner shelf,Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4) including rounding the exposed surfaces of granite complete all as specified and as directed. |
| 32 | M&L machine cut Kota stone slab as in flooring, 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over & including 20 mm thick plaster as screed bed in CM 1:6 complete all as specified and as directed. |
| 33 | All as per item No 32 above but as skirting and riser of steps including 15mm thick screed bed/body concrete in cement mortar 1:4 complete all as specified and as directed. |
| 34 | M&L cutting grinding, rubbing and polishing for old kota stone flooring with gap filling with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and as directed. |
| 35 | Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 36 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed. |
| 37 | M&L 100 mm thick Cement concrete1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base, in foundations, filling and mass concrete complete all as specified and as directed. |
| 38 | M&L Cement concrete1:4:8 type D2 (using 40 mm graded stone aggregate) as in channel and drain complete all as specified and as directed. |
| 39 | M&L Cement concrete 25 mm thick 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor complete all as specified and as directed. |
| 40 | Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 41 | M&L for factory made pre-cast RCC (1:2:4) typr B-1 with using 20mm graded stone aggregates as in manhole/gully trap cover slab, set in cement mortar (1:6) complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately under relevant item of this Schedule 'A' |
| 42 | M&L TMT bar 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 43 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290-Gde E-165 complete all as specified and as directed. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as Specified and as directed. |
| 45 | Dismantling of timber scantlings as in fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 46 | S&F Steel rolling shutters, 1.25 mm thickwith out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as Specified and as directed. |
| 47 | M&L preperation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide, primer exceeding 10cm in width or girth not otherwise described. |
| 48 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as Specified and as directed. |
| 49 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as Specified and as directed. |
| 50 | Taking down old existing tarfelt/concrete of any type/description and course from roof surface including adjoining parapets and removing the debries from the site complete all as specified and derected. |
| 51 | M&L PCC 1:2:4 Type B-1 (20mm graded aggregate) provinding as in road kerbs or mud steps and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 52 | M&L water proofing treatment to RCC roof slab, including parapet comprising with the following course of treatment/specification from bottom to top (i) Cleaning of old concrete surfaces of roof, picking sweeping cleaning the surface to remove all loose dust and thoroughly washing down with clean water and dried complete(ii) Rendering 10mm thick in CM (1:4) on existing roof surface true to level after applying cement slurry @ 3Kg/Sqm..(iii) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm.(iv) Supply and laying 3mm thick APP based olymeric membrane of approved manufacturer with weight not less than 3.60 Kgs per Sqm, reinforced with non-woven polyester febric weight not less than 150gms per Sqm. Polymeric membrane shall be taken to a height as required at site/30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(iv) One coat of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions.Note : (a) Work shall be carried out through specialized applicator approvrd by GE. Contractor shall submit sufficent documents/Credentials in support of Applicator whom he wants the work excuted.(b) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (c) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. |
| 53 | Demolition cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 54 | M&L 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path /steps laid and finishing the surface even and rough to receive the topping layer or tiling complete all as specified and as directed. |
| 55 | M & L PCC 1:2:4 type B-I ,(using 20 mm graded stone aggregate) as. in coping /benching to sides of foot path fininished fair and even etc complete all as specified and as directed. |
| 56 | M&L heavy duty 300 x 300mm & 12mm thick anti skid pavement tile (color & Shade as approved) set and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. Notes:- Design and pattern shall be approved by Engr-in-charge /GE at the time of execution of work. |
| 57 | M&L pre-polished coloured chemically treated, smooth finish exterior grade chequered tiles of size 300 mm x 300 mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed or bedding layer in cement mortar (1:6) as in path complete all as specified and as directed. |
| 58 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 59 | Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 60 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as Specified and as directed. |
| 61 | Excavating post holes or similer holes. Each not exceeding 0.5Cu M. getting out in Soft/Loose soil,returning,fillng in and ramming earth or broken rubble mixing with earh around in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 M and making good surface complete all as specified and as directed. |
| 62 | S&F Precast RCC fencing posts with (1:2:4) concrete Type B1 (Using 20mm graded stone aggregate) sectional area exceeding 100 Sq Cm but not exceeding 250 Sq Cm complete all as specified and as directed. (Note: (i)The rate quoted shall be inclusive of form work. (ii) Reinforcement will be measured and paid separately. |
| 63 | M&L TMT bars 5mm to 10mm dia ,cut to length bent to shape required in stirrups spacers and binders and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed. |
| 64 | Dismanting of Barbed wire fencing or any type and size complete all as Specified and as directed. |
| 65 | S&F galvanized. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and galvanized coating of steel wire shall confirm to the requirement as laid down for medium coated wire in IS 4826 and straining and fixing to any type of standard rails staining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc complete all as specified and as directed.(Each line wire to be measured). |
| 66 | Fixing old barbed wire with restraining & resecuring including making good staples etc all as specified as diractedNote : Serviceable galvanised barbed wire obtained from item No 78 here in before. |
| 67 | M&L mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square but (dia of neck 10mm and 10cm long) complete all as specified and as directed. |
| 68 | Supply only galvanised steel wire, (Hot dipped galvanised), 100 mm x 100 mm mesh, made up into mattresses or cages complete all as specified and as directed. |
| 69 | Fixing only chain link fencing to post old and new including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 70 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290-Gde E-165 complete all as specified and as directed. |
| 71 | S&F mild steel conforming to Fe.290.Gde-E-165 Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and as directed. |
| 72 | M & L preperation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide, primer exceeding 10cm in width or girth not otherwise described. |
| 73 | M & L PCC 1:2:4 type B-I ,(using 20 mm graded stone aggregate) as. in as in fixing of post etc complete all as specified and directed. |
| 74 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ light fittings etc and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified. |
| 75 | M&L concealed point wiring One light point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of 1.2mm thick MS sheet of appropriate size duly painted with aluminium paint inside and anti corrosive paint outside flush to wall with 3.0mm thick bakelite/plastic laminated sheet fixed with brass screws for housing switches, socket outlets, fan regulators etc duly earthed including sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. complete all as specified and as directed. complete all as specified and as directed Note:- (i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible ie on surface of RCC roof/ceiling etc, conduit shall be fixed on surface with necessary saddles at no extra cost |
| 76 | All as per item No 75 here in before but for one exhaust fan point controlled by one, one way switch . |
| 77 | All as per item No 75 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 78 | All as per item No 75 here in before but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for plug and socket point incl running of 4.0 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 79 | S & F switch piano single pole flush type 5 amps, 230 volts one way complete all as specified and as directed. |
| 80 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed . |
| 81 | S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 82 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 83 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unserviceable fitting complete all as specified and as directed. |
| 84 | S&F of Bulk head luminaire with B22 base holder suitable for 9 Watt LED inverter type bulb light IP66 grade, with and including 9 watt LED (or nearest next higher wattage) lamp (LED Bulb with B22 base 900 Lumens in normal mode and 450 lumens in power back up mode, charging time 8-10 Hrs and around 4 Hrs Power backup with inbuilt surge protection of 3 KV) (or nearest next higher wattage) and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 85 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unserviceable aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 86 | M&L fixing louver of exhaust fan of Existing size of 300mm sweep including removal of old unserviceable one complete all as specified and as directed. |
| 87 | S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including removal of old unsv sheet metal enclosure complete all as specified and as directed. |
| 88 | S&F multifunctional Digital type timer Switch 240 volts AC Single Phase complete with and including taking down old unsv one complete all as specified and as directed. |
| 89 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 90 | S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed. |
| 91 | S&F Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, including necessry connection including taking down old one complete all as specified and as directed. |
| 92 | S&F porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on incl PCC block in cement concrete 1:3:6 type C-2 for fixing strip complete all as specified and as directed. |
| 93 | Dismantling of existing loose/disturbed Aluminum strip/GI Strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete all as specified and as directed. |
| 94 | Re-fixing of servicable item recived from item No 93 have-in-before & fixing the same on roof/down conductor fixed on wooden guities/porcelain insulator /directly on roof including screws etc complete all as specified and as directed. |
| 95 | S&F aluminium strip of size 25x3.15 mm for earth continuity conductor with saddles and fixing screws complete all as specified and as directed. |
| 96 | S&F air termination single pointed aluminium rod 12mm dia and 300 mm dia complete all as specified and as directed. |
| 97 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6 mm thick, galvanised iron strip using porcelain clit /post insulators, complete all as specified and directed. |
| 98 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised iron strip 32mm x 6mm by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 of SSR Part-I including necessary excavation and earth work, PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC cover 1:2:4 type B-1 cover slab reinforced with 8 mm dia TMT bar @ 15cm C/C both ways with suitable handle of 10mm dia MS rod including providing charcoal or coke & common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 10mm bore (light grade GI watering pipe wire mesh, aluminium lugs complete in all respect GI earth wire protected by 40mm bore GI pipe and other end connected with main switch/ earth test pont, including dismantling old unserviceable earth pit complete all as specified and as directed. |
| 99 | M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised iron GI wire 4mm dia by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 of SSR Part-I including necessary excavation and earth work, PCC 1:3:6 type C-1 with 50mm thick pre-cast RCC cover 1:2:4 type B-1 cover slab reinforced with 8 mm dia TMT bar @ 15cm C/C both ways with suitable handle of 10mm dia MS rod including providing charcoal or coke & common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore (light grade GI watering pipe wire mesh, aluminium lugs complete in all respect GI earth wire protected by 15mm bore GI pipe and other end connected with main switch/ earth test pont, including dismantling old unserviceable earth pit complete all as specified and as directed. |
| 100 | S & F Post top lanterns 20 watt LED light fitting ,new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories intenally prewired including connecting up with three core twisted flexible copper conductor cable up to cealing rose and necessary mounting arrangements, complete all as specified and as directed. |
| 101 | M & L for PVC insulated unarmoured aluminium conductor cable 4 sq mm 2 core complete all as specified and as directed. |
| 102 | M & L UPVC conduit pipe heavy duty 25 mm dia including necessary excavation work for laying cable in conduit complete all as specified and as directed. |
| 103 | M&L LED flood light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen eual to/greater than 10000 lumen, system wattage 100 Watt, Ingress protection IP-66 with all acessories including taking down unserviceable light fitting complete all as specified and directed. Please Enable Macros to View BoQ information |