| 1 | Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. Fans, E.I., street light/compound lighting 3. water supply 4.LT panel maintenance. Further to provide insulation tape and Tools and Plant as per the site requirement. (AT FSD Borivali)(Staff Required)Wireman Gr I - 02 Nos on all days including holidays (rotational basis)Khallasi - 03 Nos on all days including holidays (rotational basis) |
| 2 | Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. fans,E.I.,street light/compound lighting 3. water supply 4.LT panel maintenance. Further to provide insulation tape and Tools and Plant as per the site requirement. (AT FSD Bhiwandi)(Staff Required)Wireman Gr I - 01 Nos - 4 Days a weekKhallasi - 01 Nos - 4 Days a week |
| 3 | Rewinding the motor of the table / pedstal / ceiling / exhaust fan 1200 mm / 1400 mm of all type and make and over hauling including minor repairs and testing of original speed and consumption with gaurantee for one year along with Replacing the existing Ball Bearing & Bushing of complete with alignment of shaft and testing with replacement of Capacitor . |
| 4 | Rewinding of open well submersible pump motor of all types and make upto and including 5 HP with coated copper wires and overhauling with minor repairs,etc., testing for the original speed H.P. and no load consumption & guarantee for one year |
| 5 | Replacement the existing Impellar of approved make for pump 5 HP of all types with due alignment of the shaft and tested. |
| 6 | Replacement the existing Bush and Bearing of approved make for pump 5 HP of all types with due alignment of the shaft and tested. |
| 7 | Providing of following piano type switch / socket as required. |
| 8 | 3 / 5 pin 5 / 6 amp socket outlet ISI Marked |
| 9 | 5/6 amps one way Switch ISI Marked |
| 10 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 11 | 45 watt |
| 12 | Supplying of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
| 13 | Supplying of 2.5 microfarad, 440 V rated voltage capacitor of plastic casing and copper wire terminal for fan etc. as required |
| 14 | Supplying of following size of FRLS/HFFR PVC insulated, single core copper conductor cable as required (ISI Certified) |
| 15 | 1.5 Sq.mm |
| 16 | 2.5 Sq.mm |
| 17 | 4 Sq.mm |
| 18 | Supply of LED Tube Rods 20-22 Watt as required -Lighting Color- Cool daylight (6500-7500K),Lumen output ->=100 Lumens/Watt with 2 years manufacturing warranty. |
| 19 | Supplying of 40 watt LED high efficacy wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels with 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts,etc as required and completed in all respect Lighting Color- Cool daylight (6500-7500K),Lumen output ->=100 Lumens/Watt with 2 years manufacturing warranty. (NABLCertified as per ISO / IEC Specification) |
| 20 | Supplying of 70watt LED high efficacy wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels with 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts,etc as required and completed in all respect.System efficacy.>=110 LPW . Operating voltage voltage : 140 V-270 V , rated voltage and frequesncy-240 V , 50 Hz ,Lighting Color- Cool daylight (6500-7500K) with 2 years manufacturing warranty.(NABL certified as per ISO/IEC specification) |
| 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. |
| 22 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required |
| 23 | Providing 6 SWG dia G.I. wire for loop earthing as required. Please Enable Macros to View BoQ information |