| 1 | Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. Fans, E.I., street light/compound lighting 3. water supply 4.LT Panel Maintenance. Further to provide insulation tape and tools and plant as per requirement. (Staff Required)Wireman Gr-I - 1 No (for 4 Days a Week)Khallasi - 1 No (for 4 Days a Week) |
| 2 | Supplying of following size of FRLS / HFFR PVC insulated, single core copper conductor cable as required (ISI Certified) |
| 3 | 1.5 sq mm |
| 4 | 2.5 sq mm |
| 5 | 4 sq mm |
| 6 | Supplying of 5 A to 32 A rating 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles etc.as required.(As per IS/IEC 60898-1 |
| 7 | Single Pole |
| 8 | Double Pole |
| 9 | Triple Pole and Neutral or Four Pole |
| 10 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI ≥80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 11 | 18-22 Watt |
| 12 | Rewinding of submersible pump motor of all types and make upto and including 5 HP with coated copper wires and overhauling with minor repairs etc., testing for the original speed H.P. and no load consumption & guarantee for one year. |
| 13 | Replacement the existing Impellar of approved make for electric pump 5 HP of all types with due alignment of the shaft and tested. |
| 14 | Replacement the existing Bush and Bearing of approved make for electric pump 5 HP of all types with due alignment of the shaft and tested. |
| 15 | Rewinding the motor of the table / pedstal / ceiling / exhaust fan of all type and make and over hauling including minor repairs and testing of original speed and consumption with gaurantee for one year along with Replacing the existing Ball Bearing & Bushing of complete with alignment of shaft and testing with replacement of Capacitor . |
| 16 | Supply of LED Tube Rods 20-22 Watt as required -Lighting Color- Cool daylight (6500-7500K),Lumen output ->=100 Lumens/Watt with 2 years manufacturing warranty. |
| 17 | Supplying of 40 watt LED high efficacy wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels with 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts,etc as required and completed in all respect Lighting Color- Cool daylight (6500-7500K),Lumen output ->=100 Lumens/Watt with 2 years manufacturing warranty. (NABLCertified as per ISO / IEC Specification) |
| 18 | Supplying of 70watt LED high efficacy wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels with 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts,etc as required and completed in all respect.System efficacy.>=110 LPW . Operating voltage voltage : 140 V-270 V , rated voltage and frequency-240 V , 50 Hz ,Lighting Color- Cool daylight (6500-7500K) with 2 years manufacturing warranty.(NABL certified as per ISO/IEC specification) |
| 19 | Supplying of 40 W LED post-top light fitting with IP 65 protection having energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source with opal cover diffuser. (Input voltage range 140-310 V AC, Cool Daylight (6500-7500K), Light Color: White, Lumen Output>=100 Lumens/Watt) with 2 years manufacturing warranty etc. as required. |
| 20 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 <120 lm/Watt)Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 21 | 45 watt |
| 22 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt).Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 23 | 100 watt Please Enable Macros to View BoQ information |