Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56040549

Tender For special Repair To Ceiling Fan, Exhaust Fan And Wall Fan Against Ber And Provn Of Electric Meters Work Under Ge (E) Mathura

Issued by Statutory Bodies & Commissions/Committees · Mathura, Uttar Pradesh
Tender Value
41.49 Lakhs
Estimated cost
Bid Submission
07 Jul 2026
0 days left
EMD
83000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Ceiling Fan, Exhaust Fan And Wall Fan Against Ber And Provn Of Electric Meters Work Under Ge (E) Mathura

BOQ

Name of Work:- SPL REPAIR TO CEILING FAN, EXHAUST FAN AND WALL FAN AGAINST BER AND PROVN OF ELECTRIC METERS WORK UNDER GE (E) MATHURA
Sl. No. Item Description
1S&F Ceiling Fan having sweep 1200 mm, 3-blades of aerodynamic ABS material (dust & mark resistant), energy-efficient BLDC motor single phase with inverter technology consuming not more than 28 W at rated speed of approx. 280 RPM and air delivery not less than 245 m³/min. The fan shall be supplied without LED under light and in Pearl White colour finish only. The fan shall include RF remote control with timer (up to 8 hours), sleep/breeze modes, and memory function. Noise level shall be whisper-quiet. The fan shall have 5-Star energy rating,Service value not less than 7.40, 2 years manufacturer’s warranty, and be BIS/ISI marked wherever applicable. Installation shall be carried out by authorized service personnel with all accessories complete as per manufacturer’s standard.
2S&F Ceiling Fan having sweep 1400 mm, 3-blades of aerodynamic ABS material (dust & mark resistant), energy-efficient BLDC motor single phase with inverter technology consuming not more than 28 W at rated speed of approx. 250 RPM and air delivery not less than 300 m³/min. The fan shall be supplied without LED under light and in Pearl White colour finish only. The fan shall include RF remote control with timer (up to 8 hours), sleep/breeze modes, and memory function. Noise level shall be whisper-quiet. The fan shall have 5-Star energy rating, Service value not less than 7.40, 2 years manufacturer’s warranty, and be BIS/ISI marked wherever applicable. Installation shall be carried out by authorized service personnel with all accessories complete as per manufacturer’s standard.
3S&F down rod MS grade 15 mm bore of length upto 90 cm suitable for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as directed.
4S&F down rod MS grade 15 mm bore of length upto 180 cm suitable for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as directed.
5Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as specified and directed by Engr-in-Charge.
6M&L for Point wiring for One Light/fan point controlled by one way switch 5 amp, with 1.5 Sqmm (nominal area) single core PVC insulated sheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with modular flush metal boxes with modular cover plates & frame for mounting modular switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush type switches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge as described below:-
7All as per item No. 6 here in above but for One 3 pin 5 Amps socket point controlled by one way switch on same board.
8All as per item No. 6 here in above but for One 3 pin 5 Amps socket point controlled by one switch on independent board
9All as per item No. 6 here in above but for 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed .
10Supply and Fix Modular switch 6 Amps single pole one-way, 1 Module complete as per existing, as specified and directed by Engr- in- Charge.
11Supply and Fix Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete as per existing, as specified and directed by Engr- in- Charge.
12Supply and Fix Modular switch 16 Amp single pole one way,1 Module all as specified.
13Supply and Fix Modular socket 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module complete all as specified.
14S&F in repair switch piano fiush button, single pole one way 5 amps.
15S&F in repair switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified.
16S&F in repair socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified.
17S&F in repair socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified.
18S&F step type electronic fan regulator modular type 1M complete all as specified and directed by Engr-in-Charge.
19S&F Modular Fan step regulator, 120W, 2 module complete all as specified and directed by Engr-in-Charge.
20S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed by Engr-in-Charge.
21S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting with following MCCB & MCBs with connections :-(i) MCCB 125 Amps, 4 Pole, 16 KA - 01 NosNote : - MCCB & MCCB DBs shall be of same make. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
22S&F in repair MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified.
23S&F in repair MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified.
24S&F MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V complete all as specified.
25S&F in repair MCB SPN 40-63 Amps, 'C' series, bracking cap10KA, 240V complete all as specified.
26S&F in repair MCB SPN 16-32 Amps, 'C' series, bracking cap 10KA, 240V complete all as specified.
27S&F in repair MCB SP 6 - 32 Amps, 'C' series, bracking cap 10KA, 240V complete all as specified.
28S&F MCB SP 6 - 32 Amps, 'C' series, bracking cap 10KA, 240V complete all as specified.
29S&F MCB SPN 40-63 Amps, 'C' series, bracking cap10KA, 240V complete all as specified.
30Taking down carefully by submain wiring of any type complete and making good disturbed surfaces to match with the existing surfaces all as directed by Engineer-in-Charge.
31M&L for submain wiring with Two runs of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised conduit of size 20-25mm dia conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete. Note: Two runs 4 Sq mm (P&N), one run of 4 Sq mm earth wire & One run of PVC conduit will measured as one RM).
32All as per item No. 31 here in above but for 6 sqmm.
33All as per item No. 31 here in above but for 10 sqmm
34M & L for 3 core copper conductor 0.75 sqmm conductor area, PVC insulated, PVC round sheathed multicore, 1100 volt, including suitable size Casing Caping including taking down old U/S wire complete all as specified and directed by Engr-in-charge.
35All as per item No. 34 here in above but for 2.5 sqmm
36S&F capacitors 2.5 MFD suitable for all types of fans complete all as directed by Engr in Charge. Note : Manufacturing date should be not 3 month old from date of purchase
37All as per item No. 36 here in above but for 4.0 sqmm
38S&F in repair Metal SP enclosure with 2 pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts with all connection complete all as specified and directed.
39S&F MCB SP 40-63 Amps, 'C' series, bracking cap10KA, 240V complete all as specified.
40S&F in repair of 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch/socket and complete connection all as directed.
41All as per item No. 40 but for 8 way to 12 way
42Supply, install, testing & commissioning of Microprocessor based single phase tamper proof electronic static pre paid / postpaid energy meter rating 240 Volts, 50 Hz, of range 10-60 Amps, confirming to IS 13779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWh / KVA, default /in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulatorand also compatible for Prepaid and Postpaid online energy monitoring billing system, with disconnection / reconnection through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge.(i) Meter should made properly synchronise and working with existing prepaid billing server /software / DCU (Existing make: Elmeasure) for collection of data / billing / disconnection / reconnection through remote software complete upto satisfaction level of Engr-in-charge.(ii) Cost includes two years defect liability including configuration of replaced / repaired hardware/software Please Enable Macros to View BoQ information
43Supply, install, testing & commissioning of Microprocessor based single phase tamper proof electronic static pre paid / postpaid energy meter rating 240 Volts, 50 Hz, of range 10-60 Amps, confirming to IS 13779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWh / KVA, default /in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulatorand also compatible for Prepaid and Postpaid online energy monitoring billing system, with disconnection / reconnection through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge.(i) Meter should made properly synchronise and working with existing prepaid billing server /software / DCU (Existing make: Elmeasure) for collection of data / billing / disconnection / reconnection through remote software complete upto satisfaction level of Engr-in-charge.(ii) Cost includes two years defect liability including configuration of replaced / repaired hardware/software Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56040549
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 41.49 Lakhs
LAST DATE 07-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Ceiling Fan, Exhaust Fan And Wall Fan Against Ber And Provn Of Electric Meters Work Under Ge (E) Mathura
Basic Detail
Tender No 1590/E8
Bidding Type Tender
Location
City Mathura
State Uttar Pradesh
Key Dates
Publish Date 18 Jun 2026
Submission Date 07 Jul 2026
Open Date 09 Jul 2026
Finance
Tender Value 41.49 Lakhs
Tender Fee 500
EMD 83000
Exemption Available
Document List
BOQ_865561.xls
f7c09bab-abdc-4c51-bced-4efe60058951.html
Tender1546.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 18, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_865561.xls

html

f7c09bab-abdc-4c51-bced-4efe60058951.html

pdf

Tender1546.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender