| 1 | M&L for preparation of old decorative surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed. |
| 2 | M&l for preparation of old surfaces of walls and applying one coat of whitewash complete all as specified and as directed. |
| 3 | M&L for preparation of old plastered surface of ceiling and applying one coats of white wash all as specified and as directed. |
| 4 | M&L for preparation of old surfaces of wall and applying two coats of oil bound distemper over a coat of primer including 1 mm thick putty using rolles to achieve excellent application using limited manpower including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. |
| 5 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 6 | M&L for preparation of old painted steel surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and as directed |
| 7 | Taking down Cement plaster from brick walls or concrete surfsce etc incl raking out joints, hacking for key and scrubbing down with water etc all as specified and as directed. |
| 8 | M&L for rendering 15 mm thick on other than fair faces of brick work or stone masonry surfaces upto triple sotrey building in cement plaster 1:4 finished even and fair on wall surfaces, complete, all as specified and directed . |
| 9 | Supply only liquid water proofing compound |
| 10 | M&L for rendering 10mm thick on fair faces of brick or concrete surfaces in CM 1:6 and finishing the surface even & fair complete all as specified and as directed. |
| 11 | M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and as directed. |
| 12 | M&L preperation of newly plastered surfaces of walls and applying two coats of oil bound distember over a coat of alkali resistant primer using spray machine, spray hard to receive area to achieve excellent application using limited manpower over a coat of wall care putty not less than 1mm thick complete all as specified and as directed. |
| 13 | M&L preperation of newly plastered surfaces of walls/ceilings and applying two coats of weather proof acrylic exterior paint dark shade over a coat of primer (100% Acrylic) using spray machine, spray hard to receive area to achieve excellent application using limited manpower including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. |
| 14 | M&L for preparation of existing treatment from old plastered surfaces of walls and applying one coats of cement base paint complete all as specified and as directed. |
| 15 | M&L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of primer complete all as specified and as directed. |
| 16 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 17 | M&L for preparing old plastered surfaces of walls/ceilings and applying one coats of weather proof acrylic exterior paint dark shade (100% Acrylic) using spray machine, including required scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.Note :- Weather proof acrylic exterior paint shall be applied machincally by latest machine such as trucare Graco or equivalent having minimum presure of 3300 PSI. |
| 18 | M&L for preparing old surfaces of asbestos sheets and applying one coats of weather proof acrylic exterior paint dark shade (100% Acrylic) using spray machine, including required scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. |
| 19 | Demolition of reinfoced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended workcement concrete is reinforced ( reinforcement cut as required to facilitatate demolition ) complete all as specified and as directed |
| 20 | M&L for 50mm thick sand stone slab as in chajja /cover slab set and jointed over supports in cement mortar 1:4 including demolition of existing RCC slabs, chajja etc complete all as specified and as directed. |
| 21 | S&F rolled mild steel joist, channel, angle or Tee section fixed independently without connecting plate etc cut to ordinary length i.e. within 20 mm of length indicated) of Fe 410 Gde E-250 quality including applying two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 22 | M&L for Providing, cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping, kerbs ,benching etc as directed complete all as specified and as directed. |
| 23 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed. |
| 24 | M&L for Brickwork using fly ash old size bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. |
| 25 | Dismantling timber scantling framed works 40 sqcm and over in section of any description not otherwise provided for |
| 26 | Dismantling Asbestos cement (corrugated,semicorrugated ,etc )/MS sheet in roof covering complete all as specified and directed by Engineer-in-Charge. |
| 27 | Excavation in post holes each n. exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m comp all as specified and directed. |
| 28 | S&F Pre- painted galvatume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 29 | S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as shown on drawing. |
| 30 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken bricks all as specified and directed. |
| 31 | M&L for Providing,70mm plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in floor, slab, including necessary foam work as directed |
| 32 | Taking down eaves gutters and rain water pipes, soil, waste and vent pipe ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning for refixing ( measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed. |
| 33 | S&F 110 mm PVC bore (RWP) pipes of pressure rating 6kg/per sqcm single socketed, in any length with spigot joints, fixed to walls complete all as specified and directed. |
| 34 | Supply for Pipe Supporting Clamping for Single pipe of dia 110 mm (4\\") down take pipe fixing done with Clamping System consists of Rain Water Bracket Set with Pipe Support Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3\\"): Pipe Support Clamping made of : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe having Wall Distance 75 mm (3\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs. 2. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Rain Water Bracket Set with pipe support channel for 110 mm pipe; Wall distance 75 mm (3\\") - 1 Nos. ; 2. U bolt Rubber Sleeve mounted for 4\\" (110 mm) PVC Pipe Dia. - 1 No.; and 3. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 2 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jaipur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : TD/2022/01 and TD/2024/02. |
| 35 | S&F 75 mm PVC bore (RWP) pipes of pressure rating 6kg/per sqcm single socketed, in any length with spigot joints, fixed to walls complete all as specified and directed. |
| 36 | Supply for Pipe Supporting Clamping - Single Pipe of dia 75 mm (3\\") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm (3\\"): Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 75 mm (3\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted \\"C\\" Channel with ribs to be used of size 250 mm (10\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3\\") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10\\") - 1 No.; 3. U Bolt Rubber Sleeve mounted for 75 mm (3\\") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jaipur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System : TD/2022/01 and TD/2024/02. |
| 37 | S&F in repairs 25 mm dia stainless steel alloy tubular drapery rod cut to size and fixed in position including fixing brackets, stops, rollers end caps etc. complete all as specified and as directed. |
| 38 | Dismantling old water tanks exc 500 & n exc 1000ltrs capacity and removing all as directed |
| 39 | Taking up or down steel tubing and connections , 20 mm bore complete all as specified and directed. |
| 40 | Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) |
| 41 | S & F 20 mm bore of pipe GI medium grade steel tubes, galvanised with & including all fittings and fixed complete to walls and ceilings or laid in floors. complete all as specified and as directed. |
| 42 | S&F 750 Litre capacity rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with closed top), WHITE COLOUR, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & wash out pipe etc including required dia of GI pipe, complete as specified. |
| 43 | S&F in repair Gun metal, globe or gate valves 20 mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed all as specified |
| 44 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) all as specified and directed |
| 45 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . /25mm-455gms/ 40mm- 690 gms) all as specified and directed |
| 46 | S&F Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms all as specified and directed |
| 47 | S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified & directed. |
| 48 | S & F for steel wire fabric welded steel wire fabric weight n.exc 4.0 kg/sqm fixed on to wood or steel members complete all as specified & directed. |
| 49 | S&F in repair Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 50 | Hacking out old broken glass (any kthickness, size, quality or description) from metal frames, glazed with putty. |
| 51 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading in Sqm n.exc 0.50 Sqm in each pane complete all as specified and as directed. |
| 52 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty/wooden beading in Sqm exc 0.50 Sqm in each pane complete all as specified and as directed. |
| 53 | Demolition of roof treatment including PCC/ Brick Tiles, Mud phuska, PCC padding, plastering, APP membrane complete complete of any thicknesss and in any position and removing the demolished material out of MoD land complete all as specified and as directed. |
| 54 | M&L for water proofing treatment using APP based polymeric membrane not less than 3 mm thick, weighing not less then 3.00 kg / Sqm, reinforeced with polyster non-woven fabric (weighing not less than 150 gm/sqm) laid over and including cold bitumen primer applied at the rate of 0.30 kg/sqm by forced application complete all as specified and as directed. |
| 55 | M&L for cement concrete tiles 30cm x 30cm x 20mm thick, with grey cement and no pigments, machine pressed, set jointed and pointed in neat cement slurry in floor laid over and including 15 mm thick screed bed in cement mortar 1:3 and filling the joints complete all as specified and as directed. |
| 56 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 57 | M&L for Glazed ceramic coloured tiles in vertical surface of size 450x300x 7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10 mm thick screed bed in in cement motar 1:3 complete all as specified and as directed. |
| 58 | M&L for 75 mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base, Sub floor, foors and paving etc complete all as specified and as directed. |
| 59 | M&L non skid coloured cermic Parking tiles exc. 0.11 Sqm but n exc .18 Sqm, 10mm thick set and jointed in neat cement slurry & pointed with coloured cement to match in floor over 15mm thick screed bed in CM 1:4 complete all as specified and as directed. |
| 60 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete, all as specified and directed by Engr-In-Charge. |
| 61 | M&L for 80 mm factory made chamfered edge precast concrete interlocking paver blocks any shape and size locally available of best quality and confirming to IS 15658-2006 , M-30 Grade with grey cement and pigments with appproved colour design &pattern as in footpath, parks, lawan,or light traffic ways of required strength made by table vibratory method using PU mould laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, compacted and proper embedding /laying of inter locking paver block into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with fine sand and cutting of paver block as per required size and pattern finishing and sweeping extra sand complte grey cement and pigments complete all as specified and as directed. Please Enable Macros to View BoQ information |