| 1 | Demolition of Cement concrete in ground floors and pavings n.exc 15 cm thickness below or above ground level) and removing debris out of MOD land. |
| 2 | M&L for 25 mm thick cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) to receive floor finishes etc complete all as specified and as directed. |
| 3 | M&L for Vertified Ceramic tiles 10 mm thick light shed, single charged (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM (1:4) all as specified and as directed by Engr -in-charge. |
| 4 | M&L for Items as above vertical surface as skirting incl 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed with colour cement to match on vertical surfaces as in dado (colour and pattern as approved by GE, complete all as specified and as directed by Engr-in-Charge. |
| 5 | Taking down cement plaster on stone masonry RCC surfaces, dado surfaces etc complete incl racking out joints, hacking for key scrubbing down with water |
| 6 | M&L for 15mm thick rendering in CM 1:6 on stone masonry finished even and smooth without using extra cement all as specified. |
| 7 | M/L two coat of cement based paint on new/old plastered/ unplastered surfaces over one coat of white wash on wall & including preparation |
| 8 | Hacking out old broken glass (any thickness , size , quality or description ) from metal frame incld punching or drilling out old glazing pins /spring clips and provding and fixing new ones. |
| 9 | S/F for 3 mm thick plain sheet glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane. |
| 10 | S/F for 4 mm thick figurred , pin headed glass ordinary quality & glazing with oil putty in square n exc 0.50sqm ineach pane. |
| 11 | M & L for prep of the new/old surfaces of steel & applying two coats of syn enamel paint over one coat of red oxide primer over 10 Cm width or girth all as specified. |
| 12 | M&L for pre painted galvatume aluminium zinc GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with J or L hooks and incl demolation of old sheets complete all as directed. |
| 13 | Plain, galvanised, mild steel sheeting .63 mm, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 14 | Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges 1.25 mm thick 150mm dia sheet |
| 15 | S & F for Anodised aluminium snap grid frame work ( 605x605 mm) for false ceiling all as specified and incl dismentling of existing false ceiling, etc complete, as specified and directed. |
| 16 | S&F Exposed metal frame ceiling with calcium silicate board 6mm tks of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately |
| 17 | Taking down old unserviceable point wiring ( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants,regulators, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors, ceiling etc.complete all as specified. |
| 18 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRL-SH cable 1100 volts grade, ISI - 694 marked, in PVC casing capping heavy duty ISI marked in wall/floor/roof surface including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any cost. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost. One light point controlled by one switch complete all as specified. |
| 19 | All as per item no 18 but for One fan point controlled by one switch . |
| 20 | All as per item no 18 but for one 3 pin 5 Amps Socket outlet point controlled by one switch on independent board. |
| 21 | All as per item no 18 but for one 3 pin 5 amps socket outlet point on same board with other switches. |
| 22 | All as per item no 18 but for one bell/buzer point controlled by one bell push |
| 23 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRL-SH cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any claims. |
| 24 | M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor with 4.0 sqmm single core mulfistranded copper conductor PVC(FRLS) insulated and unsheathed cable 1100v grade fixed on and including PVC casing caping fixed on wall,surfaces,ceiling etc for with 4.0sqmm single core multistandared copper conductor FRLS PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly. (for Geysers point) . |
| 25 | S & F modular switch 6A 1 module one - way 230V white ivory finish complete all as specified. |
| 26 | S & F modular switch 16A 1 module one - way 230V white ivory finish complete all as specified. |
| 27 | S & F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. |
| 28 | S & F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. |
| 29 | S&F bell electrical ding dong including hard PVC board ISI marked complete all as specified. |
| 30 | S & F Modular Bell push 6A 1 module complete all as specified. |
| 31 | Supply and fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings. |
| 32 | Supply and fixing ceiling rose surface backelite 65x50mm three terminals all as specified and directed. |
| 33 | S & F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 34 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 35 | S & F LED based security light 35 W in aluminium pressure die cast housing with touched glass cover having IP 66 Protection and with aluminium bracket including taking down of old unservicable security light complete all as directed by Engineer-in-charge. |
| 36 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250/300mm complete all as directed. |
| 37 | M & L earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 4.0 mm dia earth lead wire by means of nuts bolts washers etc as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, galvanized iron pipe light grade 15 mm diameter for protection of earthing wire, (To be concealed in wall/floor) connected to earthing test point, all as shown in electrical plate No. 3 of MES Schedule Part I. , connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a PCC (1 3 6) type C1 using 20mm graded stone aggregate earth chamber ,40mm thick RCC cover type B1 (1 2 4 ) B1 using 20mm graded stone aggregate with 8 mm dia tor reinforcrment 100mm c/cand 12mm dia MS bar handle on top of cover on ground level, 20 mm dia GI watering pipe, funnel, etc. complete and testing resistance in completion all as specified and directed. |
| 38 | Takingdown old unsv ceiling fan and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).Note- Old unsv ceiling fan deposit in E&M yard. |
| 39 | M&L for taking down of electric water heater from wall of capacity 25 ltrs, dismantling/opening the same, servicing, cleaning and replacement of wornout heating element,thermostate, MS nut bolts, washers, clamps, suitable fashner for hanging etc and made functional fully assembling, connected and testing complete. Please Enable Macros to View BoQ information |