| 1 | Taking down cement plaster on brick or stone walls, concrete surface etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 2 | M&L for rendering 15 mm thick in cement and sand mortar 1:4 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and fair, complete all as specified and as directed. |
| 3 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even & smooth without using extra cement,complete all as specified and as directed. |
| 4 | M&L for rendering 5 mm thick in cement and sand mortar 1:3 on fair faces of concrete surfaces as in ceiling including finishing the surface even and smooth without using extra cement, complete all as specified and as directed. |
| 5 | M&L for repairing the edge / corner of Chajja / roof projection and similar work by removing plaster width / girth not exceeding 150 mm and making good with 10 mm thick rendering in cement mortar 1:3 to match with existing surface complete all as specified. |
| 6 | M & L for removal of existing old painted surface and applying two coats of 100% premium acrylic exterior emulsion paint having VOC less than 50 gm/litre & excellent protection against UV, Alkali & Fungal resistance, exterior paint of required shade (Company Depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied at 0.90 litre/10 Sqm over new surfaces upto tripple storey with fully utomatic airless spray machine of paint application having an electric motor of min 1 HP with a flow speed of min 1 ltr per min having pressure 3300 PSI. Allow 6-8 hours to dry the surface of both coat of paint to achieve excellent application with 5 years perfomance warranty from manufacturers and instruction complete using limited man power including scaffolding, trestles, ladders, cradles and necessary safety measures for upto triple storey buildings, complete all as specified and directed. |
| 7 | M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and as directed. |
| 8 | M&l for preparation of old surfaces of wall and applying one coat of whitewash complete all as specified and directed. |
| 9 | M&L for preparation of old plastered surface of ceiling and applying one coats of white wash complete all as specified and directed. |
| 10 | M&L for complete removal of existing treatment and applying two coats of Distemper oil emulsion, white or tinted over 1-2 mm thick wall care putty complete all as specified and directed. |
| 11 | M&L for preparation of old plastered surface of walls and applying one coats of cement base paint including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. |
| 12 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 13 | M&L for preparation of old painted steel surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 14 | M&L for prepration of newly plastered surface of walls providing 1mm thick wall care putty and applying two coat of distemper oil emulsion including over and including a coat of alklai resitant primer complete all as specified and as directed. |
| 15 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed. |
| 16 | M&L for preparation of new plastered surfaces of wall including cornices, pilasters etc and applying two coat of cement based paint of approved colour on wall Surface including all necessary arrangement for execution of work, complete all as specified and as directed. |
| 17 | M&L Obliterating old writing of any description with synthetic enamel paint n.exc 0.10 sqm each to match the existing work complete all as specified and as directed. |
| 18 | M&L for Writing letters or figures (Block, Roman, Italic or Indian) n.exc 15 Cm high complete all as specified and as directed. |
| 19 | Dismentling timber scantlings 40 sq cm and over in section, in any position |
| 20 | M&L for roof trusses (Framed) tubular truss, crane gantries, rails and fastenings and heavy brackets framing (Hollow tubular section, beam, tee, angle, channel or flat section) FE-290 Gd-165 including distance pieces, cleats etc complete all as specified and directed |
| 21 | Dismantling asbestos cement (corrugated, semi-corrugated, etc., ) sheets in roof covering complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for pre- painted galvalume aluminum zinc coating GI based corrugated/semicorrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheeting, 0.50mm thick of an colour having tensile strength of 550 Mpa (AZ-150) in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) omplete all as specified and directed. |
| 24 | M&L for precast cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate set in CM (1:4) as in louvres and jallies, 35 mm thick (measured solid) including all mouldings but excluding frame, complete all as specified and directed. |
| 25 | M&L for opening of roof sheet n exc 3 sqm of area and refixing in the same place after replaceing vally gutter all as directed |
| 26 | M&L for 1.00 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as specified. |
| 27 | M&L for disconnecting existing tanks, setting aside for repair or cleaning and removing all scale and dirt, etc from tank of capacity exc 500 & n exc 1000 ltr and from mounths of circulating pipe with suitable chemical etc reconnecting and re-fixing in position complete all as specified and directed |
| 28 | S&F in repair 750 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete all as specified and as directed. |
| 29 | S&F in repairs PTMT body Ball cock /Float Valve 20 mm bore with epoxy coated Aluminum rod & HDPE Ball, complete all as specified and as directed. |
| 30 | Taking up or down 15 mm dia bore steel tubing and connection and refixing in new or old position of walls/ceiling/floor etc complete all as specified and as directed. |
| 31 | Taking up or down 20 mm dia bore steel tubing and connection and refixing in new or old position of walls/ceiling/floor etc complete all as specified and as directed. |
| 32 | Demolition of roof treatment any thickness including PCC , Mud phuska PCC padding, plastering , APP membrane complete treatment and in any position and removing the demolished material out of MoD land complete all as specified and directed. |
| 33 | M&L for rendering 15 mm thick in cement and sand mortar 1:4 roof/ cement concrete surfaces including water proofing compound @ 200 gm/bag and finishing the surface even and fair, complete all as specified and as directed. |
| 34 | M&L for APP based polymeric membrane not less than 3 mm thick, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr per Sqm and 2nd course of of bonding material @ 0.60 Kg/sqm which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702 and over the 2nd course the layer of membrane shhall be laid using butane torch and sealing all joints etc and preparing the surface complete all as specified & directed. |
| 35 | M &L for Cement concrete plain tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry, laid over and including 15mm screed bedding layer in CM 1:4 and filling the 2mm wide joints of tiles with cementitious grouting material complete all as specified & directed. |
| 36 | M&L for precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, roof kerbs rounded or chamfered on edges complete all as specified and directed |
| 37 | S&F in repair 110 mm bore PVC rain water pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc. including demolition of old pipes complete all as directed and as specified. |
| 38 | S&F in repair 150 mm bore PVC rain water pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc. including demolition of old pipes complete all as directed and as specified. |
| 39 | S&F in repair 200 mm bore PVC rain water pipes single socketed in any length with rubber ring joints fixed to wall incl necessary clamp etc. including demolition of old pipes complete all as directed and as specified. Please Enable Macros to View BoQ information |