| 1 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars, etc. of any descriptions, and disposing off the rubbish materials out side MoD land complete all as specified and as directed. |
| 2 | M&L for Brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 3 | M&L for Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 4 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr deep for foundation etc. n. exc 10 Sqm on plan and n. exc 1.5 mtr deep and getting out in hard/dense soil complete all as specified and as directed. |
| 5 | Returning filling including spreading, leveling, watering in layers n. exc. 25cm in any type of soil complete all as specified and directed. |
| 6 | Removing excavated soil to a distance exc. 50 mtr and n. exc 250 mtr from starting point outside MOD land complete all as specified and directed. |
| 7 | M&L for providing cement concrete type B1 (1:2:4) (using 20mm graded stone aggregates) as in copings and the like including weathering slightly rounded or chamferred angles and throating complete all as specified and as directed. |
| 8 | Dismantling fencing wire mesh, any type complete all as specfied and as directed. |
| 9 | S&F for joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing post conforming to Fe 410 W (Gde E-250 quality B) complete all as specified and as directed. |
| 10 | S&F chain link MS galvanised fencing of approved size or type weight as directed per square metre complete all as specified and as directed. |
| 11 | S&F chain link fencing PVC coated MS wire mesh roll of 10 gauge of 50 mm x 50 mm size mesh fixing firmly to the existing M.S angle vertical pole of fencingwith 8mm dia 50 mm G.I Bolt and G.I flat 35 mm x 4 mm/100mm long G.I wire cost includes all required materials, fixtures, labour and machinery etc. complete all as specified and directed. |
| 12 | S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. NOTE: each line wire to be measured. |
| 13 | S&F in repairs hot dip galvanized steel concerntina coil fencing with punched tape concerntina coil 600mm dia 10 mtr openable length (total length 90mtr), having 50 nos round per 6 mtr length upto 3 mtr heigth of wall with 9 horrizsontal RBT reinforced barbed wire, stud tied with GI satples and GI clips to retain horrizontal, including nessesary bolts or GI barbed wire tied with angle iron complete all as specified and as directed |
| 14 | S&F Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (Annealed) not less than 0.90 mm dia or securing with clips quality conforming to round bars complete all as specified and directed. |
| 15 | S&F rolled mild steel flat iron for securing wire mesh etc. posts and struts in fencing including cutting tops to shapeas directed, drilling holes,notching for wire, etc. flat ironfillets) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 completye all as specfied and directed. |
| 16 | S&F MS screw bolt (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square n exc 5 cm long dia of neck 5 to 10 mm complete all as specified and directed. |
| 17 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings and disposing off the rubbish materials out side MoD land complete all as specfied and directed. |
| 18 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated / Mangalore steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 19 | S&F Pre-painted galvalume aluminium zinc coating plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof ridges /cladding to wall, fixed with self tapping screws as specified and completed as directed. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 21 | S&F framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors, iron gate, ladders; framed balusters, ways : railing : frame work of watertanks and similar work conforming Fe-290, Gde E-165 complete all as specified and directed. |
| 22 | M&L for PCC type B-2 (1:2:4) using (40 mm graded stone aggregates) as in surface channels and drains complete all as specified and directed. |
| 23 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed. |
| 24 | Demolition of cement concrete (unreinforced) of any descriptions, in ground floors (floor topping, sub base etc) not exc 15cm thick, above or below ground level and disposing off the rubbish materials out side MoD land complete all as specified and directed. |
| 25 | M&L for 75mm thick PCC (1:3:6), type C2, (using 40mm graded stone aggregates) as in plinth protection / paving, surfae finished even & smooth with using extra cement as complete as specified and directed. |
| 26 | M&L for Hard core of gauge n exc. 63mm broken stone boulders deposited and spred and leveled in layers n.exc. 15mm thick complete all as specified and directed. |
| 27 | M&L for 100 mm thick PCC type B1 (1:2:4) (using 20mm graded stone aggregates) as in flooring, hardstanding or at any place finished even and smooth with using extra cement complete all as specified and directed. |
| 28 | M&L PCC (1:4:8) type D-2 (using 40mm graded aggregate) as in sub base complete all as specified and as directed. |
| 29 | Dismantling of interlocking tile 60-80mm thick and disposing off the rubbish materials out side MoD land complete all as specified and directed. |
| 30 | M&L for sand cushion under paver block or interlocking tiles floor including watering and consolidation complete all as specified and as directed. |
| 31 | M&L for 80 mm thick, colour as approved, machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-40 grade with grey cement and no pigment complete all as specified and as directed. |
| 32 | M&L for 60 mm thick colour as approved machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed. |
| 33 | Refixing only interlocking tiles obtained from BoQ Serial Item No. 29 above complete all as specified and as directed. |
| 34 | Demolition of reinforced cement concrete (re-inforcement cut as required to facilitate demolition) of any descriptions, in ground floors, drain covers, etc not exc 150mm thick, above or below ground level and disposing off the rubbish materials out side MoD land complete all as specified and directed. |
| 35 | M&L for Reinforced cement concrete (Nominal mix) type B1 (1:2:4) (using 20mm graded stone aggregates) walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses any thickness complete all as specified and directed. |
| 36 | M&L for providing RCPC factory made 75mm precast RCC cover slab of 3MT load bearing capacity conforming to IS : 12592 (Grade M-30) for drain cover and manhole cover, complete all as specified and as directed. |
| 37 | M&L for providing RCPC factory made 75mm precast RCC cover slab of 5MT load bearing capacity conforming to IS : 12592 (Grade M-30) for drain cover and manhole cover, complete all as specified and as directed. |
| 38 | Refixing in replacement of RCPC factory made 75mm precast RCC cover slab of 3MT/5MT load bearing capacity for drain cover and manhole cover, complete all as specified and as directed. |
| 39 | M&L for precast cement concrete (1:2:4) type B-1, (using 20mm graded stone aggregates) as landings, cover slabs(for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and as directed. |
| 40 | M&L for PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregate) as in kerb/ benching/ coping, bed plates, for fixing of hold fast,chajjas, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 41 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, reinforced concrete drain pipes etc., including cleaning or refixing or removal to store (measured overall length as fixed along the centre line over fittings and accessories) and disposing off the rubbish materials out side MoD land complete all as specified and as directed. |
| 42 | S&F PVC (SWR)110 mm bore pipes single socketed in any length with rubber ring joints and fixed to wall complete all as specified and as directed. |
| 43 | S&F 110 mm bore PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface complete all as specified and as directed. |
| 44 | S&F 110 mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specified and as directed. |
| 45 | S&F for 110mm dia PVC (SWR) vent cowl any radius complete all as specified and directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and disposing off the rubbish materials out side MoD land complete all as specified and as directed. |
| 47 | M&L for glazed earthenware tiles 149mmx 149mm (or 152.4mm x 152.4 mm) x 6mm thick, in vertical surfaces such as skirtings, dados and risers to steps etc, etc,set and jointed in neatcement slurry andpointed in white orcoloured cement to match complete all as specified and as directed. |
| 48 | S&F for heavy duty vitrified paving/ parking tiles of size n exc 0.16 sqm having minimum thickness of 10mm conforming to relevant IS code with anti skid abrasion resistant and weather resistant properties suitable for heavy pedestrian and light vehicular traffic areas,and laid over and including 15 mm thick screed bed in cement mortar (1:6) over 40mm PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregates) including cleaning and finishing complete all as specified and as directed. |
| 49 | M&L for pre-polished cement concrete designer coloured chequered tiles glossy finish of area n exc 0.16 sqm as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) over 40mm PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregates), complete all as specified and as directed. |
| 50 | M&L for glazed ceramic (coloured) tiles of size 450x300x 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 51 | M&L for Non-skid joint free ceramic coloured tiles area of each tiles (Square / rectangular) exc 0.11 sqm but n. exc 0.18 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note: Screed bed shall be measured and paid separately |
| 52 | M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 53 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed. |
| 54 | M&L for bedding layer of mortar 10 mm thick in CM (1:3) for laying wall/dado finishes complete all as specified and directed. |
| 55 | Taking down cement plaster or lime plaster of any description from stone or brick wall/ ceiling etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials out side MoD land including necessary scaffoldings complete all as specified and directed |
| 56 | M&L for rendering 20 mm thick cement plaster in CM (1:4) on external surfaces of drain brick wall or concrete surfaces etc finishing even and smooth with out using extra cement including necessary scaffoldings complete all as specified and as directed. |
| 57 | M&L for rendering 15 mm thick cement plaster with CM (1:6) on internal surfaces of drain brick wall or concrete surfaces etc finished even and smooth without using extra cement including necessary scaffoldings complete all as specified and as directed. |
| 58 | Complete removal of old decorated surfaces and M&L for applying two coats of Premium Acrylic Smooth exterior paint with Silicone additives of required shade @ 1.43 ltr/10 sqm per coat over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 59 | M&L for 1mm thick wall care putty on wall in two layers including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified and as directed. |
| 60 | M&L for applying two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & as directed |
| 61 | Preparation of old painted surfaces of steel & iron surface of any description over 10 Cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 62 | Preparing of new steel surfaces and M&L for applying two coats of synthetic enamelled paint over & including a coat of red oxide primer complete all as specified and as directed. |
| 63 | S&F in repairs for 2mm fibre glass reinforced translucent plain sheeting with two plain side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 64 | M&L for Cutting into existing man hole for connecting new drains , making good to pipe and rendering ,cutting out existing benching for and forming branch channel ( half round or 3/4 section ) in cement concrete (1;2:4) type B-1 (using 20 mm graded stone aggregate) smooth finished and benching as required for 225mm dia pipe complete all as specified and directed. |
| 65 | M&L for applying two coats of water based floor paint on cement concrete & tile floor surfaces. The surface must be completely clean, dry and free of oil, grease, plish and wax or other surfaces contaminants prior to application of paints. Apply two coats with uniform brush strokes. Second coat must be applied after 24 hrs of first coat application, complete all as specified and directed. |
| 66 | M&L for PCC type B-0 (1:2:4) using (12.5 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 67 | M&L for applying one coat of synthetic enamel paint, area exc.10cm width or girth over kerb stone or any other surfaces including preparation of surface complete in all respect as specified and directed. |
| 68 | Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar and disposing off the rubbish materials out side MoD land complete in all respect as specified and directed. |
| 69 | M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete in all respect as specified and directed. Note:- (i) Screed bed shall be measured and paid Seperately. (ii) Size of Granite shall be decided by GE |
| 70 | M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed. |
| 71 | M&L for Screed bed or bedding layer 20 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed. |
| 72 | S&F in repairs reinforced concrete pipes, class NP3, laid and jointed complete with collars, dia of bore of pipe 300mm with all fittings complete all as specified and directed. |
| 73 | S&F in repairs reinforced concrete pipes, class NP3, laid and jointed complete with collars, dia of bore of pipe 600mm with all fittings complete all as specified and directed. |
| 74 | S&F in repairs reinforced concrete pipes, class NP3, laid and jointed complete with collars, dia of bore of pipe 900mm with all fittings complete all as specified and directed. |
| 75 | S&F framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors, iron gate, ladders; framed balusters, ways : railing : frame work of watertanks and similar work conforming Fe-290, Gde E-165 for ornaments and intricate design complete all as specified and directed. |
| 76 | Removal of sludge, silt, mud, garbage, vegetation and other deposited materials from bed and sides of drains above 300 mm and up to 600 mm width and removal of these materials outside MOD land including breaking/removal of minor obstructions, lifting, collection and disposal within specified lead, dewatering if required, ensuring proper flow complete all as specified and as directed. |
| 77 | Removal of sludge, silt, mud, garbage, vegetation and other deposited materials from bed and sides of drains above 600 mm and up to 1000 mm width and removal of these materials outside MOD land including breaking/removal of minor obstructions, lifting, collection and disposal within specified lead, dewatering if required, ensuring proper flow complete all as specified and as directed. |
| 78 | Provinding, fabricating and supplying silt trap bucket of dia 600mm, height upto 800mm made from heavy- duty mild steel sheet of approved thickness (minimum 2-3 mm), including preparations (if required) for drainage, reinforced rim, and sturdy mild steel handle of adequate strength for lifting and handling. The bucket shall be properly welded, finished smooth and coated with anti-corrosive primer and two coats of enamel paint of approved quality and shade.The item includes all materials, labour, cutting, bending,welding, finishing, painting, loading, transportation to site and complete all as specified and as directed. Please Enable Macros to View BoQ information |