BOQ
| Sl. No. | Item Description |
| 1 | Earh work Excavation for Foundation in all soils and Sub soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shorting strutting amd requiring the sides of foundation |
| 2 | Cement concrete 1:4:8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specificatiors and as directed. |
| 3 | Collection and supply of Well gravel from appd quarry including cost and conveyance of all materials to site including all labour charges for filling etc.complete |
| 4 | Brick work in CM 1:5mix using country bricks ground moulded of size 23 x 11 x 7cm for the following including curing etc., complete complying with standard specifications. |
| 5 | a) For Foundation and Basement |
| 6 | b) For Super Structure in Ground Floor |
| 7 | Supplying and Fabricating and placing in position MS steel or ribbed for steel for all 5 reinforced cement concrete works as per the design given including cost of steel and binding wire in all floors etc, Complete complying with stanard specification. |
| 8 | Supplying & Erecting centering for sides & soffiots including necessary supports & strutting up to 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90 x 60cm & 10 gauge stiffened, welded with steel angle of size 25 x 25 x 3mm for boarding laid over silver oak joists Country wood) of size 10 x 6.5cm spaced @ about 90cm c/c and supported by casuarinas props of 10 - 13cm dia. spaced @ 75cm c/c etc., complete complying with standard specifications and as directed by the departmental officers. Rate for 10m2.for the following items. |
| 9 | a) Centering below Ground Level |
| 10 | b) Rate for Column Post |
| 11 | c) Rate for Roof Slab, Lintel, Beam |
| 12 | d) Rate for Sunshade |
| 13 | Cement concrete 1:1.5:3 using 20mm ISS HBG metal for all RCC item of works excluding cost of Rein forcemeat and fabricating charges,centering and shuttering but including curing and providing fixtures like fan clamps in the RCC floor or roof slabs wherever necessary and bearing surfaces of walls , sides and bottom of the slabs, beams etc., shall be finished smooth with cement mortar 1:3, 12mm thick. and with Kraft paper without claiming extra as directed by the departmental officers complete complying with standard specifications. |
| 14 | e) For Foundation and Basement |
| 15 | b) For Superstructure in Ground Floor |
| 16 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone M.Sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying |
| 17 | Finishing the top of the roof with one course of Machine Pressed Tiles of size 23 cm x 2 cm of approved quality laid in CEMENT MORTAR 1:3(One cement and three sand) 12 mm thick mixed with water proofing compound conforming to ISS by 2% weight of cement used and the joint pointed neatly to full depth of tiles with the same water proofing compound mixed with cement mortar, red oxide, etc., complete complying with standard specification |
| 18 | Plastering with CM 1:5,12mm thick.over the cement concrete for floor finish including curing etc., complete complying with standard specifications and as directed by the departmental officers. |
| 19 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work. |
| 20 | Painting two coats of Oil bound Distember for inner with best approved first quality of Distember paint of approved colour over one of priming coat etc., complete complying with standard specifications Inner Alround old surface |
| 21 | Interior / Exterior Emulsion Two coats over priming coat including cost and conveyance of all materials and labor charges etc complete. |
| 22 | Towards the charges for Supplying & fixing of Rolling shutter of Size 3.50x 2.70m including all charges in all etc |
| 23 | Towards the charges for Supplying & fixing of Steel Ventilator of Size 0.90mx 0.60m including all charges in all etc |
| 24 | Supply and fixing of 5A or 10 Amps or 20 Amps AC single phase 230 V , 50 HZ Watt hour metre on suitable TW box Complete with earth Connections of 500 V with fuse and neutral (side handle ) on suitable T.W.box with earth connection only.[SD no.124] |
| 25 | Supply and fixing of TNEB meter Board sutable for 32 A Single Phase service connection with 32 A Fuse Unit (500V) 32 A neutral link and earth link (1\\" X 1/8\\" copper plateon TW plank ofSize 375 X 300 X 19 mm with suporting TW Reepers of 1\\" thick on either side with painting with suitable bolt and nuts for fixing th TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit.[SD no.126] |
| 26 | Supply and run of 2X6.0 sq.mm (22/0.3) polythene insulatedPVC sheathed heavy duty SC.Copper conductor of 1100 V grade in 25mm dia GI pipe(Class B) suitably bent on both ends with necessary Angle iron upright and end supportes for Mains[SD NO. 71] |
| 27 | Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade on 7/20 GI bearer wire for service connection mains SD 65 |
| 28 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (6 points per coil) SD 20 |
| 29 | Wiring with 2 x 1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x 100 x 113mm TW switch box for 5A 3 pin non inter locking Wall socket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC plug point.- SD -36 |
| 30 | Supply and fixing of single box type 4'-40W flourescent tube fitting with copper choke and condenser with TW round block on wall or ceiling with flourescent tube with PVC unsheathed copper leads from terminals to the fitting of Tube Light [SD 88 ] |
| 31 | SupplyandfixingofWTbulkheadfittingwithguard(Philips/Bajaj/Crompton/K-Lite)suitablefor11WCFLlamp with CFL SD 83 |
| 32 | Supply and fixing of Zinc sheet Box for Watt Hours Meters Etc Complete. |
| 33 | GST Amount for providing Service to Government Contract Works for the above Construction & Maintenance Works. { GST Amount is the Total GST Amount for overall quoted amount (Both Construction and Maintenance) above this row in column \\"BB\\" for all works in this package}(Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD) Please Enable Macros to View BoQ information |