| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All kinds of soil. |
| 4 | Extra rates for quantities of works, executed: |
| 5 | In or under water and/or liquid mud, including pumping out water as required |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 7 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 10 | Foundations, footings, bases of columns, etc. for mass concrete |
| 11 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 12 | Extra for shuttering in circular work (20% of respective centering and shuttering items) |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 14 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 16 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 17 | 12 mm cement plaster of mix : |
| 18 | 1:4 (1 cement: 4 fine sand) |
| 19 | Providing and cement concrete surface drain with 1:3:6 (1 cement: 3coatse sand: 6 graded stone aggregate 40mm nominal size) finishing with cement mortor 1:4 (1 cement, 4 coarse sand) with a floating coat of neat cement inside the drain and its top and exposed surface i/c earthwork in excaration and disposal of surplus excarated earth etc, complete. |
| 20 | 15cmx15cm surface drain |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 22 | Supplying and laying of metal size 53mm to 22.5 mm around the ring wall upto 3.00 mtrs hight from bottom for filter media as per ther direction of Engineer-in-charge. |
| 23 | Carriage of Materials from Shri. Jagadish Halder (Near foot Bridge) House to work site by head load for an carrage lead of 550 meters. (Actual Carriage 550-50=500, 500/2=250 meters) |
| 24 | CEMENT |
| 25 | STONE PRODUCT |
| 26 | STEEL Please Enable Macros to View BoQ information |