| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 2 | All kinds of soil |
| 3 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 4 | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 5 | Providing and laying in position cement concrete of specified grade xcluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 8 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | column for platform |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 11 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 13 | In cement mortar |
| 14 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 15 | Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 16 | Above plinth level upto floor V level |
| 17 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). |
| 18 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 19 | 300x10 mm |
| 20 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 21 | 150x10 mm |
| 22 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 23 | 125 mm |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Hot finished welded type tubes |
| 26 | Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183. Density 16 kg/m?, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss-crossing Gl wire. |
| 27 | Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes including all necessary specials and fiiting i.e bends, tees, junctions (with or without door) , reducers, WC connectors, couplers, cowels, clamps, hangers, rubber rings etc complete in all respect as per the directions of Engg-in-charge. |
| 28 | 75 mm diameter (Wall Thickness - 3.2 to 3.8 mm) |
| 29 | 110 mm diameter (Wall Thickness - 3.2 to 3.8 mm) |
| 30 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 31 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineerin- charge. |
| 32 | Providing and fixing toilet paper holder : |
| 33 | C.P. brass |
| 34 | Providing and fixing PTMT towel rail/grab barcomplete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 35 | 450 mm long towel rail/grab bar with total length of appropriate size and effective height , weighing not less than 200 gms |
| 36 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 37 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 38 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 39 | 30 cm length |
| 40 | 15 mm nominal bore |
| 41 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 42 | 15 mm nominal bore |
| 43 | Providing and fixing PTMT grating of approved quality and colour. |
| 44 | Circular type |
| 45 | 100 mm nominal dia |
| 46 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 47 | 15mm nominal bore |
| 48 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 49 | 15 mm nominal bore |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 51 | 20 mm nominal outer dia Pipes |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge . External work |
| 53 | 20 mm nominal dia Pipes |
| 54 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 55 | Providing and fixing in position Toilet roll holder with flap t with fixing accessories are complete in all respects as per direction of the Engineer in charge. Cat no AKP CHR 35735P or approved equivalent. |
| 56 | Providing and fixing in position Liquied Soap Dispenser with glass bottle with necessary fitting arrangements, complete as per direction of the Engineer In Charge. |
| 57 | Providing and fixing in position CP towel ring in polished chrome with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality Complete in all respects as per direction of the Engineer in charge. (Jaquar Cat No.AKP-CHR-35721P or approved equivalent) . |
| 58 | Providing and Fixing of PVC wall Panels of Thickness 8-12 mm and Panel size to be 250 mm x3000mm having various properties such as moisture resistant,terminate resistant,uv resistant and low in maintenance as per direction of Enginner-Incharge |
| 59 | Providing and hiring of 02 Nos. Hydra (mobile crane) machines for shifting/relocation of 2 ms containers of size 12 m × 9 m x2.5m, complete with experienced operators, fuel, lubricants, T&P, and all necessary arrangements, including loading, unloading, lifting, placing at designated location, and all leads and lifts, for a period of one day(8 hrs), complete in all respects as directed by Engineer-in-Charge. |
| 60 | Extra for cutting and making openings of required size and shape in existing MS sheet for 02 Nos. doors (size 0.90 m × 1.95 m each) and 03 Nos. windows (size 0.9 m × 1.35 m each), & Exhaust size cutting 0.3m x 0.3m labour, T&P, and incidental works, complete in all respects as directed by Engineer-in-Charge. |
| 61 | Providing and laying of vinylsheet Flooring 4mm-5mm including surface preparation, cleaning and leveling of the existing floor as required, shall be fixed adhesiv ensuring bonding and smooth finish adjoining joints shall be hot finished fused use through gun type welding joints all joint shall be sealed also should having various properties such as moisture resistant,terminate resistant, as per direction of Enginner-Incharge |
| 62 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 63 | For fixed portion |
| 64 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 65 | For shutters of doors, windows & ventilators |
| 66 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 67 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 68 | For shutters of doors, windows & ventilators |
| 69 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 70 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 71 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 72 | For shutters of doors, windows & ventilators |
| 73 | Providing and fixing complete overhead shower set of approved make and quality, comprising square/rectangular stainless steel overhead rain shower (minimum 200 mm size), with wall mounted vertical sliding bar, adjustable hand shower with flexible hose (minimum 1.5 m long), diverter/mixer arrangement, and all necessary CP brass fittings.The item shall include chrome plated brass control valves, connection pipes, wall flanges, brackets, and fixing accessories, complete in all respects as per manufacturer’s specifications and as directed by Engineer-in-Charge.The shower system shall be finished in high quality chrome/plated/matte finish (as approved), including testing, commissioning, and making good the walls after installation. |
| 74 | Providing and fixing vanity type counter-top wash basin of approved quality and make, White Vitreous China, suitable for mounting on vanity/counter, including 15 mm dia CP Brass single hole basin mixer, complete with all necessary fittings, connections, cutting and making good the walls/counter wherever required, and finishing complete as per site requirement.(a) White/Grey Vitreous China counter-top wash basin (vanity type) of approved size and make, with 15 mm CP Brass single hole basin mixer. |
| 75 | Providing and fixing vanity type under counter kitchen sink ss of well quality and make, including 15/20 mm dia CP Brass single hole basin mixer, complete with all necessary fittings, connections, cutting and making good the walls/counter wherever required, and finishing complete as per site requirement.(a) with 15 mm CP Brass single hole basin mixer. |
| 76 | Providing and fixing health faucet (hand shower) of approved make and quality, comprising CP brass/ABS body with trigger, flexible stainless steel hose (minimum 1.0–1.2 m length), and wall hook/holder.The item includes all necessary fittings and accessories, complete in all respects, including fixing, testing, and commissioning, as directed by the Engineer-in-Charge. |
| 77 | Providing and fixing Dead Lock of approved make with 55mm backset, 20mm square forend prepared for euro profile cylinder including strike plate. and EPC 60mm Length one side key operation other side thumb turn and Escutcheons in SS finish complete as per direction of Engineerin-charge with necessary S.S screws etc. complete. |
| 78 | Supplying and fixing of Roller Blinds to cover windows with fabric which can block 100% light and glare. Fabric: Max width 2.5 mtr, Composition:100% polyester, Weight 360 gsm, Openness factor 0%, light fastness 6-7 grade as approved by Engineer in charge. |
| 79 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modularplate, suitable GI box and Earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 80 | Group A |
| 81 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 82 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 83 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 84 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 85 | Single pole |
| 86 | Double pole |
| 87 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 88 | 25 mm |
| 89 | Providing and fixing following rating, 20 W LED Light complete with connections,testing and commissioning etc. as required. |
| 90 | Providing and fixing 300 mm exhaust with complete installation and commissioning |
| 91 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 92 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 93 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 94 | 100 A, 16 KA |
| 95 | Supplying and Fixing Following way Single Pole and neutral,sheet steel,MCB distribution Board, 240V on surface/recess,complete with tinned copper bus bar,neutral bus bar,din bar,interconnections,powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator) |
| 96 | 12 way , double door Please Enable Macros to View BoQ information |