Tender For Supply Installation Testing Commissioning Of 1.5 Tr. Air Conditioners And Allied Electrical Works At Children Home Complex Alipur, Delhi., As Per Nit-Delhi
TDR : 56039285
Tender Notice
BOQ
2 Days Left
As Per Nit
Delhi
Tender For Supply Installation Testing Commissioning Of 1.5 Tr. Air Conditioners And Allied Electrical Works At Children Home Complex Alipur, Delhi.
Name of Work:- Supply installation testing commissioning of 1.5 Tr. Air Conditioners and allied electrical works at Children Home Complex Alipur, Delhi.
Sl. No.
Item Description
1
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cut off and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).a) 1.5 TR with 3 Star BEE Rating, Inverter Type - Hot & Cold
2
Supply installation, testing and commissioning of wall mounted/terrace mounted bracket to with stand weight of AC outdoor unit, as approved by E-in-C, weather proof, suitable primer and painted, suitable for existing outdoor unit of Split AC etc complete as reqd.
3
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
4
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
5
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
6
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
7
Providing and fixing chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. The include jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completed as per direction of Engineer in Charge. 20 mm nominal dia Pipes Please Enable Macros to View BoQ information