Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #56038543

Tender For Annual Rate Contract Forconstruction Of 200 Mm & 150Mm Dia Tw & Supply , Installation Of Pump Sets, Feeder Panels & Allied Works At Various Schemes Under Jurisdiction Of Dn Chhabra, Dist. Baran

Issued by Government Departments · Baran, Rajasthan
Tender Value
1.25 Crore
Estimated cost
Bid Submission
07 Jul 2026
5 days left
EMD
2.50 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Baran → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Annual Rate Contract Forconstruction Of 200 Mm & 150Mm Dia Tw & Supply , Installation Of Pump Sets, Feeder Panels & Allied Works At Various Schemes Under Jurisdiction Of Dn Chhabra, Dist. Baran

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Jun-2026 date extend Date 07-Jul-2026

BOQ

Name of Work:- Annual Rate Contract forConstruction of 200 mm & 150mm dia tw & supply , installation of Pump sets, Feeder Panels & allied works at various schemes under jurisdiction of Dn Chhabra, Dist. Baran
Sl. No. Item Description
1Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. (item no. 2.4)
2Nominal bore 150 mm dia.
3Nominal bore 200 mm dia.
4Add 15% extra on above item (Item No 2 to 3) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
5Add 30% extra on above item (Item No 2 to 3) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .
6Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes (item no.2.11)
7150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m)
8200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
9Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985.
10150 mm dia nominal bore of 4.8 mm thickness
11200 mm dia nominal bore of 5.4mm thickness
12Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
13Up to 2.0 KW
14Above 2.0 KW
15Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
16Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
17Up to 5.5 KW (7.5 HP) & head above 120 mtr.
187.5 KW (10 HP) & head up to 120 mtr.
197.5 KW (10 HP) & head above 120 mtr.
209.3 KW (12.5 HP) & head up to 120 mtr.
219.3 KW (12.5 HP) & head above 120 mtr.
2211 KW (15 HP) & head up to 120 mtr.
2311 KW (15 HP) & head above 120 mtr.
2413 KW (17.5 HP) & head up to 120 mtr.
2513 KW (17.5 HP) & head above 120 mtr.
2615 KW (20 HP) and above, head up to 120 mtr.
2715 KW (20 HP) and above, head above 120 mtr.
28Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
29Above 5 HP and up to 10 HP
30Above 10 HP and up to 15 HP
31Above 15 HP and up to 20 HP
32Above 20 HP and up to 30 HP
33Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
343 core 4.0 Sq.mm
353 core 6.0 Sq.mm
363 core 10.0 Sq.mm
373 core 16.0 Sq.mm
38Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
3910.0 Sq.mm, 4 core
4016.0 Sq.mm, 4 core
4125.0 Sq.mm, 3.5 core
42Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
4350 mm dia
4465 mm dia
4580mm dia
46Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
47Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
48Up to 5.00 HP
49Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
50Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
51150 mm dia
52200 mm dia
53Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
5440 mm dia
5550 mm dia
5663 mm dia
5775 mm dia
58Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approved make, including interconnections complete job.
591000 litre capacity
602000 litre capacity
61Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.
62MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
63Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
6465 mm dia
6580 mm dia
66Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
67Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56038543
AUTHORITY Government Departments
TENDER VALUE 1.25 Crore
LAST DATE 07-07-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Annual Rate Contract Forconstruction Of 200 Mm & 150Mm Dia Tw & Supply , Installation Of Pump Sets, Feeder Panels & Allied Works At Various Schemes Under Jurisdiction Of Dn Chhabra, Dist. Baran
Basic Detail
Tender No Nit No 03/2026-27PHED Division Chhabra
Bidding Type Tender
Location
City Baran
State Rajasthan
Key Dates
Publish Date 25 Jun 2026
Submission Date 07 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 1.25 Crore
Tender Fee 5000
EMD 2.50 Lakhs
Exemption Available
Document List
BOQ_1012532.xls
Tendernotice_1 (21).pdf
Tendernotice_2 (2).pdf
9e8f4e80-2bd2-447f-9cac-ff03598184a9.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Jul 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1012532.xls

pdf

Tendernotice_1 (21).pdf

pdf

Tendernotice_2 (2).pdf

html

9e8f4e80-2bd2-447f-9cac-ff03598184a9.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders