| 1 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the premises.. |
| 2 | M&L for Non skid ceramic coloured tiles 7-8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors surface set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified & directed. |
| 3 | M&L for glazed ceramic tiles, coloured, of size 350 x 250 x 7mm / 450x350x7mm, as in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:3 complete all as specified & directed. |
| 4 | Hacking out old broken glass ( any thickness, size, quality or description) from metal frame frame including punching or drilling out old glazing pins/spring clips and Supply & Fix 4mm thick Figured glass, pin head type and glazing with oil putty in square not exceeding 0.50 Sqm in each pane all as specified and as directed. |
| 5 | Taking up or down GI tubing 15 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed. |
| 6 | Taking up or down GI tubing 20 mm bore from trenches/wall including all fittings segregated and stacking the pipe complete all as specified and directed. |
| 7 | Cutting chases for Concealed water tubing and making good to facings and pointing in cement mortar 1:3, cutting not exc 10cm girth complete all as specified and as directed by Engineer in charge. |
| 8 | S&F 20mm (OD)CPVC Pipe SDR 11 & Plain CPVC SDR 11 Fittings such as Tee, Elbow, nipple and small piece of pipe in floors or fixed to wall/Ceiling complete all as specified and as directed by Engineer-in-Charge |
| 9 | S&F 25mm (OD)CPVC Pipe SDR 11 & Plain CPVC SDR 11 Fittings such as Tee, Elbow, nipple and small piece of pipe in floors or fixed to wall/Ceiling complete all as specified and as directed by Engineer-in-Charge |
| 10 | M & L cutting holes to brick wall built in cement mortar exc one brick but n.exc two bricks for inserting outlet trap/pipe and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required. |
| 11 | S&F in repair 15mm bore Chromium plated fancy type long body bib taps with wall flange, cast copper alloy with round operating knob screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed |
| 12 | S&F fancy type angle cock of brass chromium plated with long shank screwed for iron pipe and fixed to iron pipe of bore dia 15 mm complete all as specified and as directed. |
| 13 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600 mm |
| 14 | S & F Stainless steel gratings with frame, 127 mm dia, with / without hole for waste pipe connection as in repairs all as specified and as directed. |
| 15 | S&F in repair PVC waste pipe, 32 mm dia, 750mm long, suitable for wash basin & Kitchen sink complete all as specified and as directed |
| 16 | M&L for PVC (SWR) floor trap75mm dia., plain with grating including jointing with solvent cement all as specified and as directed fixed in repairs. |
| 17 | Taking down rainwater pipes / drain pipes (any size or pattern) including all fittings, heads, shoes, bends etc complete all as specified and as directed by Engr-in-Charge. |
| 18 | Supply and fix PVC (SWR) pipes single socketed 75 mm bore fixed in floors/ walls/Sunken floor up to 6th floor including necessary scaffolding works fixing cleats / clamps complete all as specified and as directed by Engr-in-Charge. |
| 19 | S&F PVC bends of 75 mm dia with access door complete all as specified and directed. |
| 20 | S&F PVC T junction single equal or unequal of 75 mm dia with access door complete all as specified and directed. |
| 21 | S&F PVC (SWR) vent cowl fixed to 75mm bore of pipes all as specified and as directed in repairs. |
| 22 | Demolition of Brickwork or stone/boulder masonry, built in Cement mortar/cement lime mortar for making provision of Exhaust fan including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed. |
| 23 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:4, complete. |
| 24 | Taking down cement plaster on brick/stone wall and ceiling including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed. |
| 25 | M&L Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing even and smooth. complete all as specified and directed. |
| 26 | M&L, for rendering 10 mm thick in CM 1:3 on concrete surface of ceiling to be finished even and smooth surfaces without using extra cement complete all as specified and directed. |
| 27 | M/L Rendering 15mm thick in CM 1:4 on fair faces of brick / stone or concrete surfaces, mixed with water proofing compound and finishing the surfaces even and fair without using extra cement in patch work at various places upto 6th storey incl necessary formwork complete all as specified & directed.(WPC shall be measured and paid separately) |
| 28 | M & L for Three coat of white wash on newly plastered surfaces of ceilings including necessary preparation of surfaces all as specified and as directed. |
| 29 | M & L for Three coat of white wash on newly plastered surfaces of wall including necessary preparation of surfaces all as specified and as directed. |
| 30 | M&L Preparing the newly plastered surfaces of wall and applying two coat of cement based paint over a coat of primer complete all as specified and directed. |
| 31 | M & L for Complete removal existing tretment on walls washing, rubbing down and stopping of existing treatment applying two coats oil bound emulsion distemper over a coat of chalk white match with existing surface all directed. |
| 32 | M & L for Demolition of Cement Concrete (unreinforced) floor/ sunken floor of any description and in any position complete all as specified and as directed |
| 33 | M & L for PCC (1:2:4) ype B1 by using 20 mm graded stone aggregate asin sub base floor and making proper slope complete all as specified and as directed. |
| 34 | Supply only liquid water proofing compound. |
| 35 | M & L for Removing building materials etc. (other than spoil) to a distance of 5km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed. |
| 36 | M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes ,metal frame,cover plate of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch. |
| 37 | All as per item No.36 above but, One fan point /Exhaust Pointcontrolled by one switch |
| 38 | All asper Item No.36 above but for One 3 pin, 05 /06 Amps socket outlet point on same board controlled by one , one way 05/06 Amps switch |
| 39 | All asper Item No.36 above but for One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch |
| 40 | M & L point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for one 15 /16 Amps socket outlet point on independent |
| 41 | M&L for Sub main wiring/power wiring complete with two runs of 2.5.0 Sqmm, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe,concealed and accessories on surface wall/floors/ with one run of PVC insulated, 2.5.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed.NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length. |
| 42 | Supply and fix in repairs Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body. |
| 43 | Supply and fix modular switch 6 Amps 1 way one module complete. |
| 44 | Supply and fix modular switch of 16 Amps single module complete |
| 45 | Supply and fix modular socket 6 Amps three pin socket two module complete. |
| 46 | Supply and Fix modular socket 16 Amps three pin socket four module complete. |
| 47 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed |
| 48 | S&F Celing Fan complete with blades , down rods ,along with electronic regulator and acessories , 230 volts, 1200 mm sweep , min air delevery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 49 | Supply & fixing bell push modular type 6 Amps complete all as specified & directed. |
| 50 | Supply anf fixing ding dong bell AC 230 V complete all as specified and as dircetd . Please Enable Macros to View BoQ information |