| 1 | Demolition of reinforced cement concrete as in beams , coloumns and footings and slab etc complete all as specified and directed. |
| 2 | Material & Labour for RCC 1:2:4 (Nominal Mix) type B1 (using 20mm graded stone aggregate) as in precast cover slabs , chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 3 | Supply & Fixing TMT bars 10m dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 4 | Demolition of cement concrete in ground floor / paving not exceeding 15Cm thick below or above GL unreinforced complete all as specified . |
| 5 | Material & Labour plain cement concrete type D2, 1:4:8, 100mm thick in sub base of floor finished even and rough to receive top layer complete all as specified and directed. |
| 6 | Material & Labour plain cement concrete type B1, 1 : 2 : 4, 50mm thick (using 20mm graded aggregate) finished even and fair without using extra cement complete all as specified and directed. |
| 7 | Forming construction Joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed. |
| 8 | Material & Labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 9 | Material and labour for machine pressed precast concrete interlocking paver block 60mm thick made of M-35 grade cement any shape and with grey cement and pigment complete all as specified and directed |
| 10 | Material & Labour for Chequered cement concrete tile 30CM x 30CM x 25mm thick with grey cement and pigment set, jointed and pointed in neat cement slurry in floors over and including cement mortar bedding 20mm thick in CM 1 : 6, complete all as specified and directed. |
| 11 | Material & Labour for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors including screed bed or bedding layer of mortar 15 mm thick in CM 1:6 complete all as specified and directed. |
| 12 | Material & Labour for Vitrified Digital parking tiles 600 x 600 mm 12 to 16 mm thick jointed and pointed in neat cement slurry in floors including screed bed or bedding layer of mortar 15 mm thick in CM 1:6 complete all as specified and directed. |
| 13 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and directed. |
| 14 | Material & Labour for 18mm to 20mm thick granite (of any type) work (table rubbed and polished) in steps ; jambs; pillars, window-sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust and admixture of pigment to match with shade of granite including provision of screed bedding layer 15 mm thick in CM 1 : 4 complete all as specified and directed. |
| 15 | Dismantling Asbestos Cement (corrugated, semi corrugated etc) sheets in roof covering complete all as specified and directed. |
| 16 | Supply & Fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr in Charge. |
| 17 | Supply & Fixing for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr in Charge. |
| 18 | Material & Labour for rolled steel in Roof trusses/ I sections (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 19 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 20 | Material & Labour for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 21 | Material & Labour Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 22 | Demolition of brick work or stone / boulder masonry, built in cement or lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 23 | Material & Labour Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 24 | Material & Labour PCC coping 1 : 2 : 4 type B-1 (using 20mm graded stone aggregate) cast in situ as in coping and weathering, slightly rounded or chamfered angles and throating etc including necessary form work complete all as specified and directed. |
| 25 | Material & Labour for rendering 15mm thick on brick or concrete surfaces in CM 1:4 on fair faces of brick work or concrete surfaces of wall finished even and smooth (without using extra cement) complete all as specified and as directed. |
| 26 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or Aluminum partitions/ insulation boards / slabs / blankets any thickness including cover fillets complete all as specified. |
| 27 | Material & Labour Powder coated Aluminum frame for doors, windows, ventilators, wall cladding with one or more rebates including joining cleat for fixing etc complete all as specified. |
| 28 | Supply & Fixing in repair 4mm thick Aluminum Composite Panel (ACP) of two aluminum skins each of having 0.25mm thick exterior grade of any colour and design as approved by GE for wall elevation to be fixed in aluminum frame work at any height complete all as specified and directed. (Make : Alstrong/VIVA/Eurobond/Virgo or equivalent) as approved by GE. Complete all as specified and directed. Please Enable Macros to View BoQ information |