Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56038267

Tender For special Rep To Bldg No P- 262 (08 X Qtrs) Of Contain Unit At Mil Stn Jamnagar Under Ge (A) Jamnagar.

Issued by Statutory Bodies & Commissions/Committees · Jamnagar, Gujarat
Tender Value
48.52 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
0 days left
EMD
97100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jamnagar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for special Rep To Bldg No P- 262 (08 X Qtrs) Of Contain Unit At Mil Stn Jamnagar Under Ge (A) Jamnagar.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Jun-2026 AMENDMENT TO BOQ BOQ 09-Jul-2026

BOQ

Name of Work:- Spl Rep to Bldg No P- 262 (08 X Qtrs) of contain unit at Mil Stn Jamnagar under GE (A) Jamnagar.
Sl. No. Item Description
1Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for keys scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
2Dismantaling floor, hearth or wall tiling including cement mortar bedding(but not backing) removing servicable tiles to store and rubbish off premises complete all as specified and as directed by Engineer-in-Charge.
3Taking down chowkats with shutter (without taking off shutters from the frames) exc 1.5 sqm but n exc 4 sm each, complete all as specified and as directed by Engineer-in-Charge.
4Taking down shutter of any description exc 1sqm each and n exc 2Sqm each, complete all as specified and as directed by Engineer-in-Charge.
5Taking down PVC Chowkats or Frames, not exc. 1.50 Sqm Each with Shutters (without Taking Off Shutters from the Frames), complete all as specified and as directed by Engineer-in-Charge.
6Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
7Demolition Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and as directed by Engineer-in-Charge.
8Demolition of brick work or stone/boulder masonary built in CM including all quoins, arches, pillars, etc but excluding ashlar, facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed by Engineer-in-Charge.
9M&F for Rendering 10mm thick on fair faces of brick masonary or concrete surfaces in cm 1:6 finished fair and even complete all as specified and as directed by Engineer-in-Charge.
10M&L for Prepration of newly plastered surface of walls by hand held sander / long handle sander including cornices, pilasters etc and applying two coat of oil bound distemper over a coat of alkali resistant priming paint, over a coat 3mm thick wall care putty complete all as specified and as directed by Engineer-in-Charge.
11M&L 15 mm thick rendering on other than fair faces of external wall of brick masonary or concrete surfaces in two layers Ist layer shall be 10mm in cm 1:6, and final layer shall be 5mm thick in CM 1:4 finished fair and even without using extra cement mixed with integral water proofing compound complete all as specified and as directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid separately
12M&L Prepration of newly plastered surface of wall by hand held sander / long handle sander including cornices, pilasters etc and appliying with Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and as directed by Engineer-in-Charge.
13M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on wall and applying three coat of white wash, complete all as specified and as directed by Engineer-in-Charge.
14M&L 5 mm thick rendering on ceiling of concrete surfaces in cm 1:3 finished fair and even complete all as specified and as directed by Engineer-in-Charge.
15M&L for Prepration by hand held sander / long handle sander including cornices, pilasters etc of newly plastered on ceiling and applying three coat of white wash, complete all as specified and as directed by Engineer-in-Charge.
16M&L complete removal of existing tretment by hand held sander / long handle sander washing down with Jet washer and appliying Airless spray two or more coats of 100 % premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 litre/10Sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10sqm complete all as specified and as directed by Engineer-in-Charge.
17M&L for Complete removal of existing treatment of old surfaces of wall including preparation of surfaces by hand held sander / long handle sander including cornices, pilasters etc and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 3mm thick wall care putty complete all as specified and as directed by Engineer-in-Charge.
18M&L Preparation of old surfaces of wall removing nails including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) , filling undulation and holes with putty and applying one coat of oil bound distemper with roller finish.on walls etc complete all as specified and as directed by Engineer-in-Charge.
19M&L for Preparation of old plastered surfaces of ceiling by hand held sander / long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge.
20M&L for Preparation of old plastered surfaces of wall surface by hand held sander / long handle sander including cornices, pilasters etc and applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge.
21M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete complete all as specified and as directed by Engineer-in-Charge.
22M&L for Complete removal of existing roof treatment, removing rubbish off the premises, cleanning the surface and preparing to receive new roof treatment and applying roof treatment as under:- (a) Applying coat of bituminios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry(the primer and the membrane to be used shall be of same manufacturer, (b) Supply and laying of minimum 3 mm thick APP modified polymeric membrane weighting not less than 3 KG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with proplane or abutance gas using torch with minimum 75 mm side overlap and 100 mm end overlap. (c) two coat of approved aluminium paint over membrane. (d) all overlaps and joints shall be sealed as per manufacturers instruction complete all as specified and as directed by Engineer-in-Charge.
23Roughening surfaces of old concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc incl brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and as directed by Engineer-in-Charge.
24M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in cm (1:3) complete all as specified and as directed by Engineer-in-Charge.
25M&L for Rendering 10mm thick in CM(1:3) with using water proofing compound on fair faces of brick work/ Fasia and roof surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
26M&L for PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course complete all as specified and as directed by Engineer-in-Charge.
27S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-Charge.
28S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, all as specified and as directed by Engineer-in-Charge.
29M/L 2nd class Hardwood chowkhats, plain, solid, straight, wrought, framed, rebate on the solid,rounded or chamfered put together with glue pinned at joints complete all as specified and as directed by Engineer-in-Charge.
30S&F rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, Fe 410-W (GdeE- 250) quality A drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed by Engineer-in-Charge.
31M&L for Hold fast for fixing of chowkats and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-Charge.
32M&L for Providing cement concrete 1:2:4 type BO (using 12.5mm graded aggregate) in cills, steps, seismic and other similar bands plinth coureses string courses lacing courses parapets and railing copings kneelers apex bed plates kerbs. etc.. water troughs and the like including wethering slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge.
33S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutters (any number of panel) with lock rail and panel of 12mm thck veneered particle board with commercial veneering on both faces. the size of rail and styles as per IS-1003 part - I , kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge.
34S&F Glazed and skelton shutters, 35 mm thick of Second class hard wood open rebated and prepared to receive glass, gauge etc without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), chemically treated, complete all as specified and as directed by Engineer-in-Charge.
35S&F powder coated anodised aluminium alloy sections 3 tier track sliding windows series B of size 92mm x 31.75mm x 1.2mm and shutter section 18mm x 43mm x 1.30mm weight 0.547 kg/m Jindal or equivalent duly fitted with neoprene beading, glazing clips, tinted glass panes 4.80/5.0 mm nominal thickness, stainless steel wire cloth 0.36 mm dia and average width of aperture 1.4 mm, aluminium alloy handles etc including taking down old window in any size and make complete all as specified and as directed by Engineer-in-Charge.Note : rate shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle etc
36S&F powder coated anodised aluminium fixed louvered ventilator frame of size 63.5 x 38.1 x 1.01 mm thick or equivalent section fixed in vertical position with aluminium vertical members and half portion to be provided with 4 mm thick pinhead glass and remaining portion to be louvered using 4 mm thick pinhead glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm incl necessary channel frame work, including rubber gasket and aluminium beading including taking down old ventilator in any size and make complete all as specifiedNote : rates shall include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading etc
37S & F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
38M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
39S&F in repair 100mm extruded brass handles, fabricated type polished and fixed with nut, screw and washer of mild steel complete all as specified and as directed by Engineer-in-Charge.
40S/F in repairs for Block boards, 18/19mm thick grade 2 quality, interior grade, decorative type with veneer/lamination as approved on both face fixed with screws to timber and frame work complete all as specified and as directed by Engineer-in-Charge.
41S&F 30mm width of flap continuous (piano) hinges, mild steel, bright finish complete all as specified and as directed by Engineer-in-Charge.
42S&F 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-Charge.
43S&F Floor door stopper of aluminium alloy body and tongue, anodised, 140 mm with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-Charge.
44S & F in repair stainless steel wire cloth 0.36mm dia of wire and avarage width of aperture 1.40mm and fixed with stainless steel wire staple in any type of windows/doors complete all as specified and as directed by Engineer-in-Charge.
45M/L for two coats of synthetic enameled paint over a coat of pink primer to new wooden surfaces of any description exc 10 cm width or girth complete all as specified and as directed by Engineer-in-Charge.
46S&F Mild Steel Butt hinges, heavy weight, cold rolled, of size 100 mm complete all as specified and as directed by Engineer-in-Charge.
47S&F aluminium anodised, barrel tower bolt of extruded section 150mm long, complete all as specified and as directed by Engineer-in-Charge.
48S&F 125 mm long aluminium handle, cast type, anodised complete all as specified and as directed by Engineer-in-Charge.
49S&F aluminium anodised, barrel tower bolt of extruded section 100mm long, complete all as specified and as directed by Engineer-in-Charge.
50S&F 100 mm long aluminium handle, cast type, anodised complete all as specified and as directed by Engineer-in-Charge.
51S&F aluminium alloy anodised sliding door bolt with hasp staple(bolt type) ,250 mm long,and fixing clip of sheet cast or extruded section or fixing bolt cast aluminium alloy and fixed complete all as specified and as directed by Engineer-in-Charge.
52S&F Aluminium anodised 75mm hasp and staple ,safety type with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed by Engineer-in-Charge.
53M&L for screed bed or bedding layer 15mm thick in CM 1:4 on floor to receive tile complete all as specified and as directed by Engineer-in-Charge.
54S & F Non Skid Ceramic Colour Tiles 7 to 8 mm thick area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
55S & F vitrified tiles 8 to 10 mm thick area of each tiles n exc 0.36 Sqm in floor , skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
56M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
57M&L for 18-20mm thick Kota stone slab machine cut, in stair treds, bathroom platforms, shelf platforms etc. bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing complete over and including 15 mm thick screed bed in CM 1:4 and polishing complete all as specified and as directed by Engineer-in-Charge.
58M&L for 18-20mm thick Kota stone slab machine cut, in riser of steps, skirting, dado and pillar etc. bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing complete over and including 10 mm thick screed bed in CM 1:3 and polishing complete all as specified and as directed by Engineer-in-Charge.
59Moulding to kota stone slab/ granite including rounding off edges for 20 mm thick slabs including grinding and polishing complete all as specified and as directed by Engineer-in-Charge.
60M&L for rendering 10 mm thick in CM 1:3 on wall to receive tile complete all as specified and as directed by Engineer-in-Charge.
61M& L for glazed ceramic coloured tile in vertical surfaces 300x450x7 mm thick set and jointed in neat cement slurry and poited in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
62M&L for 75mm thick cement concrete,1:3:6 Type C-2( Using 40mm graded aggregate) as in plinth protection , subbase complete all as specified and as directed by Engineer-in-Charge.
63Taking up or down steel tubing and connections dia of 25 mm bore complete all as specified and as directed by Engineer-in-Charge.
64Supplying and laying of 25 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer-in-Charge.
65Taking up or down steel tubing and connections of 20 mm dia bore complete all as specified and as directed by Engineer-in-Charge.
66Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape complete to walls and ceilings or laid in floors including all connected brass cpvc fittings and cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer-in-Charge.
67Taking up or down steel tubing and connections of 15 mm dia bore complete all as specified and as directed by Engineer-in-Charge.
68Supplying and laying of 16 mm outer dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, concealed joint with CPVC adhesive taflon tape in any requirement complete to walls and ceilings or laid in floors iincluding all connected brass cpvc fittingsand cutting grooves, filled with CM1:6 complete all as specified and as directed by Engineer-in-Charge.
69Dismantling overhead water tanks of capacity exc 250 & n exc 500 ltrs and removing from site complete all as specified and as directed by Engineer-in-Charge.
70S & F in repairs 500 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms) , hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as specified and as directed by Engineer-in-Charge.
71S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe/upvc pipe complete all as specified and as directed by Engineer-in-Charge.
72S&F in repair fancy type Bib taps, cast copper alloy 15mm dia with long handle, screwed down, screwed for iron pipe incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed by Engineer-in-Charge.
73S&F in repair Fancy type Stop valves angle /concealed 15mm bore, cast copper alloy, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed incl female brass threaded adaptor on CPVC pipes complete all as specified and as directed by Engineer-in-Charge.
74S&F in repair 15mm fancy type Pillar taps, cast copper alloy, with long heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-Charge.
75S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engineer-in-Charge.
76S&F in repairs PVC(SWR) pipe 110 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed by Engineer-in-Charge.
77S & F PVC (SWR) junction single (single T) equal or unequal 110mm bore, with access door complete all as specified and as directed by Engineer-in-Charge.
78S&F in repair PVC (SWR)110 mm bend bore bends with access door any radius complete all as specified and as directed by Engineer-in-Charge.
79S&F in repairs PVC(SWR) pipe 75 mm dia, conforming to IS-13592-1992 type 'B', single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
80S&F in repairs PVC(SWR) bend any radius, 75 mm dia complete all as specified and as directed by Engineer-in-Charge.
81S & F PVC (SWR) junction single (single T) equal or unequal 75mm bore, without access door complete all as specified and as directed by Engineer-in-Charge.
82M&L for cement concrete 1:2:4 type B-0 (using 12.5 mm aggregate) sub base of floors , mass concrete complete all as specified and as directed by Engineer-in-Charge.
83Taking down floor trap/nahani trap of any description any size and making good to disturbed portion with cement concrete type B-1 1:2:4 with water proofing compound complete all as specified and as directed by Engineer-in-Charge.
84M & L 75mm outlet dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-Charge.
85S & F in repair vitreous china wash down water closet pan (pedestral pattern) white including fixing to flushing cistern and flush pipe and plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel hinging device complete all as specified and as directed by Engineer-in-Charge.
86S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern ) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti syphonage pipe etc complete making good to floor complete all as specified and as directed by Engineer-in-Charge.
87Supply and fixing in repair PVC flushing cistern, white, 10ltr capacity with 32mm dia flush pipe any lenth fixed to water closed complete all as specified and as directed by Engineer-in-Charge.
88S & F in repair Vitreous China wash basin, white, flat back, size 550mm x 400 mm with & including a pair of cast iron brakets embedded in PCC 1:3:6) type C-1 (using 20mm graded stone aggregate), blocks of size 10x7.5x15cm , and 32 mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed, ( excluding tap ) including PVC Waste coupling of PTMT 32mm dia (half or full threaded) Minimum weight 45gms , washers and Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed by Engineer-in-Charge.
89S&F in repairs Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, including beding in cement mortar on to dwarf walls, or cast iron cantilever brackets, connecting union to waste pipe upto sqm each , overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete including removing exixting sink complete all as specified and as directed by Engineer-in-Charge.
90S&F in repairs glass corner shelf 300 mm (with ABS Bracket 300x 600) as selected including removing existing shelf, complete all as specified and as directed by Engineer-in-Charge.
91S&F in repair Soap dish of any type (S/S) approximate size 160x160 fixed to plugs with chromium plated brass screws including taking down old complete all as specified and as directed by Engineer-in-Charge.
92S&F in repair Brass chromium plated Tublar towel rail 20mm dia D type 60 cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
93S&F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed by Engineer-in-Charge.
94S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer-in-Charge.
95S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and as directed by Engineer-in-Charge.
96S&F in repair 25mm dia stainless steel curtain rail, cut in required length and size to fit with opening incl fixing on bracket with necessary screws fitted on bracket and decorative nobs on sides with necessary arrangement complete all as specified and as directed by Engineer-in-Charge.
97S&F in repairs curtain rod side brackets of stainless steel, angular or cantilever type fixed to wall with 02 nos screws on each bracket and fitted screws for fixing curtain rod incl CP/stainless steel carved decorative design plain metal colour nobs with fixing arrangement for curtain rod using a screw complete all as specified and as directed by Engineer-in-Charge.
98M&L for racking of cracks upto 5 mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size complete all as specified and as directed by Engineer-in-Charge.
99M&L for racking of cracks exc 5 mm but not exc 10mm wide ,preparation and crack filling with ready to use crack fiber reinforced filler /chemical based crack fillers by approved manufacturer and filling as per manufacturer instructions in walls,roofs of any type or size complete all as specified and as directed by Engineer-in-Charge.
100M&L 15mm thick rendering in cement plaster 1:3 mixed with Water Proofing Compund on bottom and side walls of sunken floor incl finished even and smooth w/o using extra cement complete all as specified and as directed by Engineer-in-Charge. Note :- water proofing coumpound shall be measured and paid seperatly.
101Removing the plant/growth of any description size, any location of external surfaces of walls shafts by cutting & remvoing the roots completely spraying the suitable chemical (each plant 100 ML) in the removed portion to avoid re-growth & making good damaged portion to match the existing surfaces by PCC type B0 (1:2:4) 12.5 mm graded aggregate complete all as specified and as directed by Engineer-in-Charge.
102Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls/chajja by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and as directed by Engineer-in-Charge.
103M&L Cleaning vertical and horizontal surfaces of sunken slab using wire brushing followed by sanding with emery paper for loose materials/dust and applying two coats of epoxy resin component (Dr. Fixit DAMPGUARD or equivalent) solution/mix using nylon brush pouring Base part in appropriate container followed by the Hardner part and mix thoroughly to attain homogeneous smooth paste and dilute the mixed compound with water in ratio 1 part Base: 1 part Hardner: 1 part water by slow addition and mix thoroughly until a brushable consistency is obtained, first coat will be allowed to dry for 6 to 8 hrs before application of second/final coat) incl curing treated surface for 24 hrs complete incl applying evenly a coat of blown bitumen @ 1.5kg/sqm over entire treated surfaces incl spout holes complete and all as specified as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge.
104M&L for 40 mm thick PCC 1:2:4 type B-0 using (12.5 mm graded stone aggregate mixed with and including liquid water proofing compound as per manufacture instruction in bottom of sunken floors floors complete all as specified and as directed by Engineer-in-Charge.
105Supply only of Intergral water proofing compound as per manufactures instruction complete all as specified and as directed by Engineer-in-Charge.
106Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth on brick walls complete all as specified and as directed by Engineer-in-Charge.
107M&L for Brickwork with fly ash moudular bricks built in CM (1:4) , straight or curved on plan exc 6m mean radius, complete all as specified and as directed by Engineer-in-Charge.
108S&F in repairs 2 in 1 wall maounted mixer (15 mm bore) with quater turn fittings and provision for overhead shower with 115 mm bend pipe and wall flange, cast copper alloy with capstan heads, fancy type chromium plated (robotic electroplating for everlasting lustrous shine) with 2 water volume adjustment knobs one both side to control the flow of temperature ,screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete for mixing hot and cold water for tap and shower complete all as specified and as directed by Engineer-in-Charge.
109M&L for cement concrete 1:4:8 type D-2 (40mm aggregate) foundation , filling mass etc.concrete complete all as specified and as directed by Engineer-in-Charge.
110M&L for hardcore (broken stone or boulders) of gauge n exc 63mm, deposited, spread and levelled in layers n exc. 15cm thic, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge.
111M&L factory made 60mm thick Machine pressed precast cement concrete coloured, rubber moulded, designer(reflecting type) interlocking pavour block of M-35 grade confirming to IS 15658-2006 of shape and size as directed with coloured top laid over and including 50mm thick sand cushioning, joints of blocks filled with dry sand and compacted complete all as specified and as directed by Engineer-in-Charge.
112Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
113Taking up/down GI tubing and connections 40mm size of pipes including all fittings complete all as specified and as directed by Engineer-in-Charge.
114S&F tube GI medium grade 20mm dia with all fittings laid in trenches complete all as specified and as directed by Engineer-in-Charge.
115S&F tube GI medium grade 25mm dia with all fittings laid in trenches complete all as specified and as directed by Engineer-in-Charge.
116S&F tube GI medium grade 40mm dia with all fittings laid in trenches complete all as specified and as directed by Engineer-in-Charge.
117S&F gun metal gate valvs with iron wheel head ,screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and as directed by Engineer-in-Charge.
118Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
119Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed by Engineer-in-Charge.
120Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed by Engineer-in-Charge.
121Taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed by Engineer-in-Charge.
122Taking down ceiling fan/ Exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M Jamnagar complete all as specified and as directed by Engineer-in-Charge.
123Taking down existing energy meter from site and deposit to MES storeyard and refixing the same meter after completion of work complete all as specified and as directed by Engineer-in-Charge.
124M & L for Point wiring of One light point controlled by one, one way switch 5 Amps using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed by Engineer-in-Charge.
125Description all as per item No 125 above but for One fan point/ exhaust fan point controlled by one, one way switch 5 Amps complete all as specified and as directed by Engineer-in-Charge.
126Description all as per item No 125 above but for One light point controlled by one, two way switch 5 Amps complete all as specified and as directed by Engineer-in-Charge.
127Description all as per item No 125 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed by Engineer-in-Charge.
128Description all as per item No 125 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad complete all as specified and as directed by Engineer-in-Charge.
129Description all as per item No 125 above but for One bell point controlled by one, bell switch 5 Amps complete all as specified and as directed by Engineer-in-Charge.
130Description all as per item No 125 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point) complete all as specified and as directed by Engineer-in-Charge.
131Description all as per item No 125 here in before but using 4.0 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. (power point)
132Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and,cutting chases for concealed water,tubing or concealed conduit wiring,,etc., and making good, cutting not,exc 10 cm girth ®(stone massonary) complete all as specified and as directed by Engineer-in-Charge.
133S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified and as directed by Engineer-in-Charge.
134S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and as directed by Engineer-in-Charge.
135S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified and as directed by Engineer-in-Charge..
136S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engineer-in-Charge.
137S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and as directed by Engineer-in-Charge..
138S & F modular step type fan regulator (BLDC) 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed by Engineer-in-Charge.
139S & F Bell push modular 6 Amps single module complete all as specified and as directed by Engineer-in-Charge.
140S & F metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and as directed by Engineer-in-Charge.
141S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed by Engineer-in-Charge.
142S & F lamp holder, PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and as directed by Engineer-in-Charge.(Kitchen).
143S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed by Engineer-in-Charge.
144M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit complete all as specified and as directed by Engineer-in-Charge.
145S & F sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer-in-Charge.
146S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed by Engineer-in-Charge.
147S & F for MCB Tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge.
148S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge.
149S & F MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed by Engineer-in-Charge.
150S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired with and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed by Engineer-in-Charge.
151S & F LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed by Engineer-in-Charge.
152S&F for electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed by Engineer-in-Charge.
153S & F wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed by Engineer-in-Charge.
154S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25/35 watts with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and as directed by Engineer-in-Charge.
155S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and as directed by Engineer-in-Charge.. (Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted).
156M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion complete all as specified and as directed by Engineer-in-Charge. Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.
157Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out complete complete all as specified and directed by Engr in Charge
158M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and as directed by Engineer-in-Charge.
159Supplying and laying un-reinforced precast concrete cable cover, LV low voltage type -I flat size 250 mm x 150 mm x 40 mm complete all as specified and as directed by Engineer-in-Charge.
160Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in trenches complete all as specified and as directed by Engineer-in-Charge.
161Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
162S&F XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 25 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and as directed by Engineer-in-Charge.
163Supply and fixing GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking down old unserviceable GI pipe complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56038267
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.52 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Rep To Bldg No P- 262 (08 X Qtrs) Of Contain Unit At Mil Stn Jamnagar Under Ge (A) Jamnagar.
Basic Detail
Tender No 8244
Bidding Type Tender
Location
City Jamnagar
State Gujarat
Key Dates
Publish Date 25 Jun 2026
Submission Date 09 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 48.52 Lakhs
Tender Fee 500
EMD 97100
Exemption Not Available
Document List
8244tender.pdf
BOQ_865291.xls
ed97039f-4053-4dec-9aa1-0bfcba6f6fff.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
pdf

8244tender.pdf

xls

BOQ_865291.xls

html

ed97039f-4053-4dec-9aa1-0bfcba6f6fff.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail