| 1 | M & L for B check maintenance in 20 KVA Make : Greaves No:110803140550 silent type DG set installed at STP Khambhaliya including the change of lub oil ,Engine oil & fuel filters, B check all as specified by the manufacuterer and directed. (Note : Engine oil will be measured and paid separately) (i) Replace the Lubricating Oil. (ii) Replace lubricating oil filter elements. (iii) Replacing lubricating oil by pass filter element (iv) Replace the fuel filter element. (v) Check engine coolant (vi) Replacing Hydraulic governor oil (vii) Clean the crank case breather (viii) Check Turbo charger (for turbo fitted engines) (ix) Engine oil/Radiator coolant oil will measured and paid separately. (x) Cost of labour for fixing the spares supplied and measured here in after including in the unit rate of the item including testing all as directed by Engr-in-Charge. Note : (a) All major parts incorporated in the work will be measured and paid separately under relevant items of sch 'A'. (b) All spare parts should be as per the recommendation of original manufacturer. (c) Repairs to radiator/alternator will be measured and paid for separately under relevant items of sch 'A'. |
| 2 | All as per item no 1 above but for Diesel engine generator set 25KVA installed at(i) Main Pump House Khambhaliya Make: Kirloskar 1000001 and (ii) Dwarka Pump House Make:Kirloskar SM No.527/6026/DG/12 |
| 3 | All as per item no 1 above but fot Diesel engine generator set 35KVA installed at AFNET Area Khambhaliya Make: Kirloskar No;0920598 |
| 4 | All as per item no 1 above but fot Diesel engine generator set 50KVA Air Men Mess Khambhaliya Make:Mahindra No.N4D16500841 |
| 5 | All as per item no 1 above but for Diesel engine generator set 100KVA installed at(i) New offr mess khambhaliya Make:Mahindra No ERG2D13109 |
| 6 | All as per item no 1 above but for Diesel engine generator set 15KVA installed atTech Area at Dwarka Make: Kirloskar 1221092 |
| 7 | M&L for replacement of battery upto 12 V 150 Ah maintenance free for DG set complete all as specified and directed. |
| 8 | M&L for replacement of battery upto 12 V 90 Ah maintenance free for DG set complete all as specified and directed. |
| 9 | Supply only Coolant oil including taking out unserviceable oil complete all as specified and directed. |
| 10 | Supply only Engine oil 15W40 confirming to specification complete all as specified and directed. |
| 11 | Supply and fix in replacement AVR unit suitable for DG set upto 100 KVA incl connecting with alternator and control panel circuits, starting and testing complete all as specified and directed. |
| 12 | S & F in repair electronic controller for AMF panel of capacity 15 to 100 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel complete all as specified and directed. Make : Wood Word / Deep sea Electronic |
| 13 | M & L for replacement of DG Set door Hinges & accessaries for 63 KVA complete all as specified and directed. |
| 14 | Periodical maintenance / servicing of solar water heater,flat plate collector type, storage type with electrical backup of capacity 100 litres, as per manufacturer instruction comprising of the following works at different locations: (a) Complete cleaning of solar system, removing of dirt dust etc. (b) Cleaning of heating surface glass with glass cleaning solution. (c) Opening of cold & hot water connection draining out deposited water removing of mud turbidity etc & cleaning with fresh water. (d) Checking of Non return valve, Electrical backup system & sacrificial anode & tighten the connection. (g) Replacement of unserviceable spare part will be carried out under respective item only. Note:- (i) Unserviceable spares parts will be measured & paid separately as supply only. (ii) Work shall be executed through Authorised service technician of Tata Solar BP / Delta./Red ren. |
| 15 | Supply and fix in repairs hot water tank suitable for 100LPD solar geayer for flat colllector type complete all as specified and directed. |
| 16 | Taking out unserviceable / defective / damaged GI pipe 15mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed. |
| 17 | Taking out unserviceable / defective / damaged GI pipe 20mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed. |
| 18 | Taking out unserviceable / defective / damaged GI pipe 25mm bore steel water tubing and removing away all unserviceable pipe from site, complete all as specified and directed. |
| 19 | S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 20 | S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 20mm bore with and including all fittings such as bends , elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 21 | S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 25mm bore with and including all fittings such as bends, elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed. |
| 22 | S&F in repair bronze gate valve class-1 for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed. |
| 23 | S&F in repair bronze gate valve class-1 for 20mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed. |
| 24 | S&F in repair bronze gate valve class-1 for 25mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed complete all as specified and directed. |
| 25 | S&F 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered (ISI Marked) conforming to IS 12701: 1996 hoisted and fixed in position, including ball brass valve 20mm bore, fixed as in repair complete all as specified and directed. |
| 26 | Supply and fix ball valves high pressure of PTMT of 15 mm with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 142gms) complete all as specified and directed. |
| 27 | Supply and fix ball valves high pressure of PTMT of 20 mm with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210gms) complete all as specified and directed. |
| 28 | Supply and fix only solar panel water heater element 2000/3000 W with thermostat cut off electric water geyser temperature controlling sensorsuitable for 230 V ac complete all as specified and directed. |
| 29 | Cleaning of solar water syntex of capacity 200 litre to 500 litre at by draining out storage water completely throwing out manually with buckets and cleaning of inner surface of bottom and walls of tank by removing complete accumulated sludge/ mud, dirt etc with wire brush and finally washing with fresh water and disinfecting the reservoir with 2% solution of potassium permaganate or Chlorine solution including writing date of cleaning with white synthetic enamel paint and removing sludge scale mud etc to a distance not exceeding 50 metre and depostting complete all as specified and directed. |
| 30 | M&L for fabrication & fixing in position mild steel work for covers, supporting clamps of pipe, ladders,support structure for solar water system mild steel section such as angle, flat, Tee, nut & bolt etc etc, cutting, welding cold or hot drilling holes in any shape or size and fixing arrangement, including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete using steel section of Fe 290 Grade -165 including dismantling of old steel work complete all as specified and directed. |
| 31 | Servicing and testing of Addressable fire alarm system (non comprehenvice maintenance) having appx 20 devices & 1 loop Addressable fire alarm panel for 3 visits in every two months and emergency callout.make-RavelNote-1-Check of condition of control panel 2-Check Correct unobstructed sittings of detectors and call points3-Test Detectors or call point in each zone4- Test all alarm sounders5-Correct fuse rating,secure battery treminals6-Cleaning of control panel |
| 32 | Supply, installation testing and commisioning of analog addressable type self accimating multi,sensing smoke detector with standard mounting base LED,address switch complete with jucntion box for mounting on surface/on false ceiling/below false floor complete all as specified and directed. |
| 33 | Supply, installation testing and commisioning of addressable dual action manual call station with address switch and allmounting accessories complete with junction box for mounting on surface complete all as specified and directed. |
| 34 | Supply and fix in repair sounder / hooter 24 V DC of siitable for existing fire alarm system complete all as specified and directed. |
| 35 | M&L for rectification of leakage from 200mm HDPE 10 Kg/Sqcm bore pipe line by fixing by cutting & removing of pipe & providing new pipe as required, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement complete all as specified and directed. |
| 36 | M&L for rectification of leakage from 140mm HDPE 10 Kg/Sqcm bore pipe line by fixing by cutting & removing of pipe & providing new pipe as required, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement complete all as specified and directed. |
| 37 | M&L for rectification of leakage from 110mm HDPE 10 Kg/Sqcm bore pipe line by fixing by cutting & removing of pipe & providing new pipe as required, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement complete all as specified and directed. |
| 38 | M&L for rectification of leakage from 75/90mm HDPE 10 Kg/Sqcm bore pipe line by fixing by cutting & removing of pipe & providing new pipe as required, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement complete all as specified and directed. |
| 39 | M&L for rectification of leakage from 63/40mm HDPE 10 Kg/Sqcm bore pipe line by fixing by cutting & removing of pipe & providing new pipe as required, connecting both side with old line by providing necessary fittings with accessories complete inluding all necessary earth work with testing all as per ground requirement complete all as specified and directed. |
| 40 | Supply and fix HDPE pipe PN 10 of 100mm with all fittings complete all as specified and directed. |
| 41 | Supply and fix HDPE pipe PN 10 of 75mm with all fittings complete all as specified and directed. |
| 42 | Supply and fix HDPE pipe PN 10 of 50/65mm with all fittings complete all as specified and directed. |
| 43 | Supply and fix CPVC pipe of 16 m with all fittings and connection complete all as specified and directed. |
| 44 | Supply and fix CPVC pipe of 20 mm with all fittings and connection complete all as specified and directed. |
| 45 | Supply and fix CPVC pipe of 25 mm with all fittings and connection complete all as specified and directed. |
| 46 | Supply and fix CPVC ball valve of 20 mm with all fittings and connection complete all as specified and directed. |
| 47 | M & L for replacement of unsv / defective diffuser for 200 KLD package type as per manufacture instruction after taking out existing complete all as specified and directed. |
| 48 | M&L for taking out complete multirgrade media / pebbles of various sizes 4mm to 16m and sand 0.2 mm to 0.4 mm complete and refiliing with new pebbles and sand in multigrade filter of STP as per existing complete all as specified and directed. |
| 49 | Material and labour for disconnecting pipe connection, draining out the old sewage deposited in raw sewage sump, filter sump and treated water supply chamber removal of deposits and cleaning of entire section of plant with fresh water complete all as specified and directed. |
| 50 | Material and labour for disconnecting pipe connection, draining out the old sewage deposited in screener and grit Chamber removal of deposits and cleaning of entire section with fresh water complete all as specified and directed. |
| 51 | M&L for taking out and replacement of unsv / defective and replacement MBBR media as per manufacture instruction complete all as specified and directed. |
| 52 | M&L for repairing / servicing of electric motor cap 7.5 HP couplled to air compressor, AC 3 phase, by dismantling the motor and coupling pulley and sent to work shop for repair. Removal of existing burnt out copper winding wire, cleaning of slots using suitable reagents and rewinding with super enamelled copper winding wire of appropriate gauge to achieve required RPM, varnsihing, drying, ovening, overhauling, greasing, painting and assembling the same after complete repair, connecting with pump and making necessary electrical connection and testing of motor after installation complete all as specified and directed.Note: Contractor shall be responsible for maintaining required RPM after repair, non compliance of speed considered as incomplete repair. |
| 53 | M&L for repairing / servicing of electric motor cap 5HP couplled to sludge transfer pump, by dismantling the motor and coupling pulley and sent to work shop for repair. Removal of existing burnt out copper winding wire, cleaning of slots using suitable reagents and rewinding with super enamelled copper winding wire of appropriate gauge to achieve required RPM, varnsihing, drying, ovening, overhauling, greasing, painting and assembling the same after complete repair, connecting with pump and making necessary electrical connection and testing of motor after installation complete all as specified and directed.Note: Contractor shall be responsible for maintaining required RPM after repair, non compliance of speed considered as incomplete repair. |
| 54 | M&L for dismantling of air compressor/blower and seperating the assembly of compressor pump and electric motor 7.5 HP from horizontal air tank carefully by opening rubber belt, flywheel, nuts, bolts, foundation bolts, change the unserviceable parts like air regulator, oil, ball bearing, gear, cylinder head gasket kit, oil seal, injection rings after repair, reconnecting accessories and other fittings/fixtures complete all as specified and directed. |
| 55 | M&L for Repairing / Servicing of sludge transfer feed pump set of capacity 3.0 m3/hr by opening / dismantling the pump complete over hauling taking out defective/unsv/worn out parts and replacing the and bearing,gasket,wear ring,bush etc reassembling the pump set after repair including replacing the rusted bolts, nuts washers etc and testing complete all as specified and directed. |
| 56 | Supply and fix 200/160 mm size CTD joining for connecting HDPE pipe with HDPE Pipe / GI pipe, along with connected accessories like rubber ring nut bolts etc and taking out old / unsv complete all as specified and directed. |
| 57 | Supply and fix 100 mm size CTD joining for connecting HDPE pipe with HDPE Pipe / GI pipe, along with connected accessories like rubber ring nut bolts etc and taking out old / unsv complete all as specified and directed. |
| 58 | M&L for Repairing / Servicing of self priming non clogging pump set of capacity 64m3/hr to 96m3/hr by opening / dismantling the pump complete over hauling taking out defective/unsv/worn out parts and replacing the following spare parts and reassembling the pump set after repair including replacing the rusted bolts, nuts washers etc and testing complete all as specified and directed. |
| 59 | Motor end cover |
| 60 | Bearings as per existing(set of two) with bearing sleeve |
| 61 | Air/ Pile Plug , joint ring , Made of SS 316 |
| 62 | Fasteners in Liquid, Made of BHT Steel |
| 63 | Double Mechanical seal , Made of C vs P S Ceramic |
| 64 | Cable entry kit , Made of Neoprene rubber |
| 65 | O Ring for Upper and lower bearing |
| 66 | Stuffing box bush |
| 67 | Casing ring |
| 68 | Impeller with key for impeller |
| 69 | Oil for mechanical seal |
| 70 | Wear plate as per existing MOC |
| 71 | Alignment of pump impeller with motor shaft |
| 72 | Repairing of shaft by remetaling/weiding, grinding and polishing |
| 73 | Supply and fix LED solar post top with built in solar panel LED light and lithium battery with charge controller and 2 PIR sensors wiyh 360 degree coverage IP 65 complete all as specified and directed. Make- Havells cat part No-BUDZ 1W 5700K Solar Bollard light or equivalent make as mentioned in Appx 'B' to PS. |
| 74 | Supply and fix LED solar post top with built in solar panel Led light and lithium battery with charge controller and 2 PIR sensors wiyh 360 degree coverage IP 65 complete all as specified and directed.Make- Havells cat part No-FlORIO 20W 5700 K Solar Post Top or equivalent make as mentioned in Appx 'B' to PS. |
| 75 | Supply and install Dosing system (Dual tank Model No- FTPS AQUA 1005 & 1006) Mechancally actuated, variable eccentric type motor dosing system. High flow rate of 0-30 LPH & High pressure of 10kg/cm2. Flanged vertically Mounted with TEFC induction Motor Directly coupled.Motor capacity 0.25HP, 1440 RPM. Including accessories injection check valve (1/2\\" NPT -M \\"Y\\" strainer 1/2\\" BSP-F), Suction Strainer (Y Type PP/PVC) and Discharge tubingh 3Mtrs. Accessories must include the following :- (A) Preparation tank Model No AQUA1005 of net capacity 170ltrs. FRP dosing tank dia 650xnet Height 375 + conical 300mm. gross Height with stand 1000mm consisting of water inlet line, outlet with \\"Y\\" stariner. Drain overflow conical bottom for sludge deposition, Pot hole with cover, Level gauge Agitator 120Watt 960RPM single phase flange mounted motor with plastic shaft and impeller (B) Service Tank Model NOAQUA1006 of net capacity 100ltrs of FRP dosing tank Top dia 540mm x Bottom dia 480mm x Height 575mm consisting of water inlet line, Dosing pump inlet arrangement, Drain Ocverflow level gauge, inspection port, Agittator 120Watt 960RPM single phase flange mountred motor with plastic shaft and impeller. Provision of mounting lid. Pump fitted with mounted on heavy duty MS fabricatyed frame and painted with anticorrosive paint Make- Aquafit of Aquajio Technoliogies and MAIC India Please Enable Macros to View BoQ information |