|
| 1 | Water supply pipes and fittings |
| 2 | OD357242/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.a) 25 mm uPVC pressure pipes as per IS : 4985-2021 ( 5metre length )PIPEUPVCP/E PLUMBING 025MM 5 MTR LG (LF) |
| 3 | OD357476/2025-2026:Supply, Installation , testing and commissioning of water supply system pipe workincluding solvent welded/threaded fittings (tees, elbows, unions, reducers, coupling etc ) GI \\"U\\" bolts, GIslotted rails,rail legs,accesories,etc. for supply riser, distribution risers,ring mains suspended pipes, etc.with pipes and firrings as per uPVC schedule 40/80 suitable for working pressure of 20 bars all inaaccordance with drawings and relevant standards.Pipe supporting / clamping details:- For verticalshaft piping, pipes shall be clamped/ supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm)rails & rail legs. For suspended piping, pipe shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavydity GI slotted rails (2.5mm) & slotted rails shall be suspended using 10mm threaded road,10mm anglefastner, nuts & washers to the slab.b) 20mm u PVC pressure pipes as per IS : 4985-2021(PIPEUPVCP/E PLUMBING 020MM 5 MTR LG (LF) |
| 4 | OD357506/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.h ) PIPE UPVC Q/F 6 KG 110MM 5 MTR LG (LF) |
| 5 | OD357510/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.g) 75 mm uPVC IS 4985-2021 Above Ground/Open Piping (Nominal Dia)(PIPEUPVC Q/F 10KG 075MM 5 MTR LG (LF) |
| 6 | OD357528/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.f ) 63 mm uPVC IS4985-2021 Above Ground/Open Piping(PIPEUPVC Q/F 10KG063MM 5 MTR LG (LF) (Nominal Dia) |
| 7 | OD357536/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.e) 50 mm uPVC IS 4985-2021 Above Ground/Open Piping (Nominal Dia)(PIPEUPVC Q/F 10KG 050MM 5 MTR LG (LF) |
| 8 | OD357552/2025-2026:Supply, installation, testing & commissioning of water supply system pipe workincluding solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GIslotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc.with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordancewith drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping,pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& raillegs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GIslotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts& washers to the slab.d) 40 mm uPVC IS4985-2021 Above Ground/Open Piping (Nominal Dia) (PIPEUPVCQ/F 10KG 040MM 5 MTR LG (LF) |
| 9 | OD358504/2025-2026:Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab.c) 32 mm uPVC IS4985 -2021 above ground /open piping (PIPEUPVC Q/F 10KG 032MM 5 MTR LG (LF) |
| 10 | 18.17.1:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 11 | 18.17.2:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 12 | 18.17.3:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 13 | 18.17.4:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 14 | 18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 15 | 18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore |
| 16 | 18.17.1A:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 17 | OD358533/2025-2026:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) Brass full way valve with C.I wheel (screwed end ) 100mm dia. |
| 18 | 18.19.5.1:Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal |
| 19 | 18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 20 | OD358543/2025-2026:Supply, installation, testing and commissioning of high pressure float valve with bronze construction, copper floats, with screwed end fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards 65 mm Float Valve. |
| 21 | OD358564/2025-2026:Supply, installation, testing and commissioning of spring loaded, vertical mounted brass air release valve with forged brass body, forged brass chamber, with screwed end fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards 20 mm dia automatic air release valve. |
| 22 | OD358639/2025-2026::Providing and fixing automatic level controller with panel, control cabling,cabling, Automatic OHT Level Control system Consists of Water Level Float Switch with control Cable for water supply ,including all accessories, which required to complete the system for working conditions as per specifications Automatic Level controller. |
| 23 | OD358655/2025-2026::Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel,automatic changover switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. FLUSH WATER LIFTING PUMP (UG Tank to oh Tank) Duty conditions:-240 LPM @ 45 M Head (One Duty + One standby) (WTP-01/02). |
| 24 | Drainage system |
| 25 | OD358726/2025-2026:Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. b) 75 mm uPVC SWR 6Kg/sqcm pipes - Above Grade |
| 26 | OD358768/2025-2026:Supply, installation, testing and commissioning of SWR pipes conforming to 6kg/sqcm pipes for pipes below 75mm dia including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets,etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification.Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. 50 mm uPVC SWR 6Kg/sqcm uPVC pipes - Above Grade |
| 27 | OD358918/2025-2026:Supply, Installation, testing and commissioninh of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards. uPVC deep seal multiple floor Trap 100 mm dia. |
| 28 | OD358937/2025-2026:Supply and Installation at site PVC Low Noise SWR Grooved Ringfit pipe made of mineral reinforced polypropylene using [As per IS 13592] ISI Marked Dual Medial Rubber and Plastic Seal Material complete with special fittings, Plain Bends, Door bends, Couplers, Reducers, Single Tees, Door Tees, Double Tees, Reducing Tees, Plain Ys, Door Ys, Double Ys, Elbows , Door Elbows etc. Adapters, Air vents, Clamping with GI U Clamps as required for firmly installing the pipes. Testing of the system for leakage and Air tightness (Make: Astral Silencio)(for Restaurant Waste Water) Low Noise pipe 110 mm pipe. |
| 29 | OD358956/2025-2026:Supply, installation, testing and commissioning of UPVC under ground drainage pipes conforming to IS 15328 including necessary fittings, excavation, connection to manholes, bedding the pipe in constant intervals, back filling, removing the surplus etc. as per IS:1742-1983 and testing the lines to required hydrostatics pressure for below ground(seware) installation all in accordance with the drawings and relevant standards. Below ground installation 160 mm pipe uPVC pipes, |
| 30 | OD358983/2025-2026:Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets, etc. for above the ground installation(shafts/suspended) all inaccordance with the drawings and specification. Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle Fastner, nuts & washers to the slab. Shaft & suspended Piping 160 mm uPVC class B |
| 31 | OD359001/2025-2026::Supply, installation, testing and commissioning of SWR pipes conforming to PVC IS 13592 Class B for 75mm dia and above, & 6kg/sqcm pipes for pipes below 75mm dia and uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets, etc. for above the ground installation(shafts/suspended) all in accordance with the drawings and specification. Shaft & suspended Piping 110 mm dia |
| 32 | OD359011/2025-2026:Supply, installation, testing and commissioning of SWR pipes conforming to uPVC IS 13592 Class A pipes for rain water & vent piping including necessary fittings and accessories clamped in position & jointing with O-rings, supports, brackets, etc. for above the ground installation(shafts/suspended) all in accordance with the drawings and specification. Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle Fastner, nuts & washers to the slab. 75 mm uPVC class A for rain water/vent pipe |
| 33 | OD359043/2025-2026:Supplied by client, storage, erection, testing & commissioning of Submersible Drainage suction pumps (3 nos on a 2 duty + 1 standby basis) with electric starter, cutter blade,control panel,automatic changeover switch, Automatic level controller and all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays etc as specified and as shown on drawings and complying to relevant standards. Duty conditions:- 6.0LPS @ 18 M Head (One Duty + One standby) |
| 34 | OD359055/2025-2026:Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank,rain water Sump, soak pits. 600X600 mm size - Heavy Duty cover ( 20 Ton lod bearing ) |
| 35 | OD359095/2025-2026::Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank, rain water Sump, soak pits. 600X600 mm size - Medium Duty cover( 2.5 ~10 Ton load bearing ) |
| 36 | 19.4.1.2:Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith Sewer bricks conforming to IS: 4885 |
| 37 | 19.7.1.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 38 | 19.8.1.1:Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 |
| 39 | Waster and STP treated water tanks |
| 40 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 41 | 5.33.1.1:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementAll work upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum |
| 42 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 43 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 44 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm |
| 45 | 22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystallineslurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm. |
| 46 | 5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 47 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 48 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 49 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 50 | Plumbing line |
| 51 | OD359230/2025-2026:Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards.Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle Fastner, nuts & washers to the slab. c) 80mm uPVC ( SH-80 ) |
| 52 | OD359238/2025-2026:Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards. Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. b) 65 mm dia uPVC (SH -40) |
| 53 | OD359261/2025-2026:Supply, installation, testing & commissioning of water supply system pipe work including solvent welded/threaded fittings(tees, elbows, unions, reducers, coupling, etc.), GI \\"U\\" bolts, GI slotted rails, rail legs, accessories, etc. for supply riser, distribution risers, ring mains, suspended pipes, etc. with pipes and fittings as per uPVC schedule-40/80 suitable for working pressure of 20bars all in accordance with drawings and relevant standards. Pipe supporting/ Clamping details:- For vertical shaft piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted (2.5mm) rails& rail legs. For suspended piping, pipes shall be clamped/supported by using 8mm GI \\"U\\" bolts to heavy duty GI slotted rails(2.5mm) & slotted rails shall be suspended using 10mm threaded road, 10mm angle fastner, nuts & washers to the slab. a) 50mm uPVC (SH 40) above ground/open piping ( Nominal dia) |
| 54 | 18.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes |
| 55 | 18.8.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes Please Enable Macros to View BoQ information |