| 1 | Electrification |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 4 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 5 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 6 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 7 | OD11829/2026-2027:Supply and fixing pressure die cast housing LED Bulkhead with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications including giving connection with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the Original wiring and making good the surface as required. (Philips make VistaGlow WT140W LED7S NW/CW PSU S1 PC or Techno commercial equivalent approved by engineer in charge) |
| 8 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 9 | OD38292/2026-2027:Supply Conveyance, installation, testing and commissioning of 20W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) (Havell make model : Centura Neo LED Flood Light 20 W 6500 K IP66 or eqivalent.) |
| 10 | OD19396/2026-2027:Supply, Conveyance, installation, testing and commissioning of of LED Post top Luminaire having power consumption not more than 35 W and light output not less than 3500 Lumens with a nominal efficiency 100 lumen/watt. Internal surge protection up to 4 KV ,IK 5 with IP 65 protection The housing should be of non-corrosive ADC12Grade high-pressure die-cast. The Luminaire diameter must be minimum 300mm for larger area coverage .The Luminaire should be having Minimum 50000 Burning hours(L70B50) with CRI ≥70, SDCM< 5 and co-related colour temperature (CCT) of 4000- 5700K. The luminaire should be capable of withstanding voltage stress of `440V for 8 Hrs , should have an auto shutdown at 325V and have an auto recovery feature , Under Voltage protection with Input Voltage Stress of 100V for 48 Hrs. The Luminaire should have a 4 KV in the Luminaire. Total of 45 hits across all the three modes as per IEEE 62.41.2 The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire with PF>0.95 and THD<10%.Luminaire and driver shall be separately BIS approved of same make. Philips make Model BGP200 LED35 CW PSU GR CPC SPD or equivalent |
| 11 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 12 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 13 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 14 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 15 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 16 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 17 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 18 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 19 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 20 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 21 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 22 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 23 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 24 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 25 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 26 | 90.9.1.1:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.50x50mm Cable Management System with base and lid |
| 27 | 90.9.1.7:Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap |
| 28 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 29 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 30 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 31 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 32 | 90.12.7.3:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 33 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 34 | OD11583/2026-2027:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 40/32 mm or nearest size |
| 35 | OD38365/2026-2027:Supply & laying of DWC pipe through the wall/ parapet using clamps noted along with the DWC pipe, making good the damages colour washing etc. as required. 40/32 mm or nearest size |
| 36 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 37 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 38 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 39 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 40 | OD27299/2026-2027:Supply, installation testing and commissioning of 1.5 HP Open well Vertical type submersible motor pump set at 20-48 m head range Model No.15D6/6 Deccan/equivalent make (ISI marked) delivery size 40 mm having discharge 0.666 lps at 40 m head using leak proof materials as required and laying in the existing well including fixing delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connection as per the direction at site. |
| 41 | 90.14.28.12:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 1.5 HP submersible motor pumps (DOL) |
| 42 | OD25101/2026-2027:Supply, and jointing of 40mm ( 1½ Inch )size , ASTM 80 schedule uPVC flange adapter set with required leak proofing materials etc as required. |
| 43 | OD27092/2026-2027:Supply, laying and jointing of 40mm ( 1½ Inch ) size , ASTM 80 schedule uPVC pipe with required specials as delivery pipe using required leak proofing materials etc as required. |
| 44 | OD30389/2026-2027:Supply and providing of 40mm 6 Kg/cm2 PVC pipe with specials and giving necessary connections by using leak proof materials and good the damages, color washing with required accessories and clamps etc. including cutting and making good the walls, painting the exposed portions as required. |
| 45 | OD38398/2026-2027:Supply and providing of 40mm 6 Kg/cm2 PVC pipe with specials and giving necessary connections by using leak proof materials and good the damages, color washing with required accessories in the ground including the excavation of the soil, refilling the soil etc as required. |
| 46 | OD27145/2026-2027:Supply and providing 40mm Bronze Ball Valve (Screwed) (Make Zoloto 1008A or Techno commercial equivalent) |
| 47 | OD25097/2026-2027:Supply, and jointing of 40mm ( 1½ Inch ) size , ASTM 80 schedule uPVC Pipe bend 90 degree with required leak proofing materials etc as required. |
| 48 | OD25113/2026-2027:Supply and providing 40mm ISI marked Bronze Horizontal/Vertical Check Valve (NRV) (Screwed) IS:778 (Make Zoloto or Techno commercial equivalent approved by engineer in charge) |
| 49 | OD27180/2026-2027:Supply, and jointing of 40x25mm (1 ½ x 1 Inch ) size , ASTM 80 schedule uPVC Reducing Tee with required leak proofing materials etc as required. |
| 50 | OD27181/2026-2027:Supply and providing 25mm Bronze Ball Valve (Screwed) (Make Zoloto 1008A or Techno commercial equivalent) |
| 51 | OD27304/2026-2027:Supply and fixing flat iron clamps made of 40X6 mm flat iron clamp of 40 cm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required. |
| 52 | OD27186/2026-2027:Providing, laying and fixing 50 mm Dia G.I. pipe (medium class) for supporting the delivery pipe to the top of the well,The pipe placing across of the well and clamping each other using required accessories etc |
| 53 | OD25118/2026-2027:Supply and laying 12 mm or nearest size nylon rope |
| 54 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 55 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 56 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 57 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 58 | OD11725/2026-2027:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 59 | OD11726/2026-2027:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 60 | OD11754/2026-2027:Supply and providing 25x6 mm brass bolt and nut with washer including drilling holes as required.(excluding GST) |
| 61 | OD11756/2026-2027:Supply and providing 25x3mm brass nut and bolt etc. as required. |
| 62 | OD11755/2026-2027:Supply and providing 12x3mm brass nut and bolt etc. as required |
| 63 | OD23143/2026-2027:Supply, fixing, testing & commisioning of 36W(+/-2) All in One Solar street light with not less than 6000 Lumens light output and more than 160 Lumens per watt system efficiency. 50,000 burning hours as per L70. Built in maintenance free Lithium Ferro Phosphate Battery(Life Po4) with >308Wh capacity, 12v 60w solar panel module with ultra sonic sensor. The housing shall be made of CRCA Housing in non corrosive 500 hours NSS Salt spray tested finish and UV stabilised polycarbonate cover with lens for each LED's. MPPT Charge controller and driver efficency shall be greater than 90%. Equivalent to Philips BRP111 LED60/ kesslec /Osram and must have fied on existing octagonal pole |
| 64 | 90.15.3.3:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters |
| 65 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 66 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 67 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 68 | OD23781/2026-2027:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete. |
| 69 | OD38502/2026-2027:Supply and providing 16 A, 230 V 3 way open type bakelite connector strip |
| 70 | OD38503/2026-2027:Supply and fixing Syntex junction box GSJB 1616 with provision for fixing SP/DP MCB for terminating street light cable. |
| 71 | OD38511/2026-2027:Supply and fixing following rating Surge Protection Devices (3P+N) ,Conforms to IEC 61643-11, Type 1+2(Protection against direct and indirect lightning surges) , Maximum Discharge Current - Imax up to 100 kA in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make L&T or Techno commercial equivalent) Please Enable Macros to View BoQ information |