| 1 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submain wiring/cable as required DSR 5.18 |
| 2 | Supplying & installing following sizes of perforated Hot Dipped Galavanised Iron cable tray (Galavnisation thickness not less than 50 microns) with perfoaration more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenderes including GI Bolts & nuts etc. as required DSR 4.6 |
| 3 | 50mm(H) x 300mm(W) x 50 mm(H) and 1.5 mm Thick DSR 4.6.4 |
| 4 | 50mm(H) x 150mm(W) x 50 mm.(H) and 1.5 mm Thick DSR 4.6.2 |
| 5 | Supplying & installing following sizes of perforated Hot Dipped Galavanised Iron cable tray \\"bends\\" (Galavnisation thickness not less than 50 microns) with perfoaration more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenderes including GI Bolts & nuts etc. as required DSR 4.7.4 |
| 6 | 50mm(H) x 300mm(W) x 50 mm(H) and 1.5 mm Thick DSR 4.7.4 |
| 7 | 50mm(H) x 150mm(W) x 50 mm.(H) and 1.5 mm Thick DSR 4.7.2 |
| 8 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, Splitler dampers,vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required and shall also confirm to the BIS specifications. DSR 30.12 |
| 9 | 0.80 mm (22 gauge) GSS DSR 30.12.1.2 |
| 10 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications DSR 30.15 |
| 11 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required DSR 30.16 |
| 12 | Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. DSR 30.17 |
| 13 | Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. DSR 30.18 |
| 14 | Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. DSR 30.20 |
| 15 | Fire damper DSR 30.20.1 |
| 16 | Actuator DSR 30.20.2 |
| 17 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. DSR 30.23.1 |
| 18 | 19 mm thick |
| 19 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : DSR 31.14 |
| 20 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm DSR 31.14.3 |
| 21 | 28.58mm dia (OD) (Hard drawn) with tube thickness 1.2 mm DSR 31.14.8 |
| 22 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall Split Type Air Conditioners, complete with Indoor unit (IDU), Out door unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU ) including drain pipe R-32/R-410/R-407 Green Refrigerant, wireless, Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical DSR 32 (E&M) |
| 23 | Inverter Type - Cooling Only |
| 24 | 1.5 TR with 5 star BEE Rating DSR 32.2.3 |
| 25 | Providing and fixing of Voltage Stablizer suitable for 1.5 TR AC Unit 15 Ampere capacity working range 150 VAC to 285 VAC with low and high voltage cut off protection , built in thermal overload protection, digital / analog display for input / output voltage, wall mouted type, with metal cabinet complete of make V-Guard model VND 400 or equivalent model of Deol, Luminous, Microtech . |
| 26 | 4 KVA |
| 27 | Supply, Installtion, Testing and Commissioning of Air Cooled (Hot & Cold) Ducted split type air conditioning units with controller, refrigerant R410A or equivalent permitted green refrigerant, Cooling Coil of Copper with aluminium fins complete of approved make, to the satisfaction of EIC.The rates quoted should include lifting, shifting and positioning of Indoor and Outdoor unit as per site requirements, making hanging arrangement for Indoor Units and hanging arrangement/ foundation for outdoor units. The units should be factory charged, however any top up required, Nitrogen leak testing, Oil Charging, Vacuumization, Canvass Connections should also be included in the rates. Make: Daikin, Carrier, Voltas, Bluestar. |
| 28 | 11 TR (+/- 5%) |
| 29 | Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts/plenum using open cell elastomeric nitrile rubber foam, anti-microbial, density 180 kg/cum min. and Fire Safety Class I ( BS 476 Part 7 ) cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). to the entire satisfaction of EIC |
| 30 | 10mm thick Sound board |
| 31 | Providing and fixing of UPVC Pipe of Class 5 (10KG/CM2) of various sizes for condensed water drainage from Indoor unit to nearest disposal point as per site to the entire satisfaction of EIC. |
| 32 | All necessary ,Supports ,civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof should be included in the rates quoted. |
| 33 | 40 mm dia with 6mm Class O Nitrile Insulation |
| 34 | 32 mm dia with 6mm Class O Nitrile Insulation |
| 35 | Providing and fixing of LT Power Cable, XLPE, Armoured with Copper conductor conforming to IS 7098 Part 1 of approved make and making connections complete with cost of thimbles. |
| 36 | 4C x 10 Sq. mm Copper (armoured) Conductor |
| 37 | Providing and fixing of LT Control Cable, XLPE, Un-Armoured with Copper conductor conforming to IS 7098 Part 1 of approved make and making connections complete with cost of thimbles. |
| 38 | 6 Core x 1.5 Sqmm |
| 39 | Main Electrical Panel-1 (CPRI Approved) |
| 40 | Design,Supply,Installation,Testing and Commissioning Electrical Control Panel of cubical construction , floor mounted type , fabricated out of 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, power coated of approved shade, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mounting and internal wiring, earth terminals, numbering etc complete in all respect suitable for operation of 2 no's Ductable Split Units of 11 TR capacity with following incoming and outgoings, suitable for operation on 415 V, 3 Phase, 50 Hz AC Supply with enclosure protection IP 42 as required. |
| 41 | INCOMING SUPPLY |
| 42 | 4 Pole MCCB of required capacity with breaking capacity 50kA |
| 43 | Spreader Link with phase Barriers |
| 44 | Rotary Mechanism = 1nos |
| 45 | METERING SECTION |
| 46 | Voltmeter with Selector Switch for Incoming and Outgoing Supply |
| 47 | Ammeter with Selector Switch and CT's of required capacity |
| 48 | Control MCB 's |
| 49 | Indication Lamps LED Type RYB = 3 no's |
| 50 | OUTGOING |
| 51 | Outgoing Feeders - (2 Nos + 1 Spare ) each having 1 x MCB ( TPN ) of 40 Ampere |
| 52 | PANEL |
| 53 | Fabrication of Powder Coated Enclosure made out of CRCA sheet having 2 mm for load bearing surfaces & 1.6 mm for non load bearing surfaces ,duly processsed powder coated having Siemens grey colour. (Outdoor Type with weatherproof canopy design) |
| 54 | Assembly charges of Aluminium Bus Bar of required capacity, TPN Electrolite grade E91 having cross section 1 x 50 x 10 mm or suitable for Phase & 1 x 50 x 5 mm or suitable size for Neutral & Current carring capacity 1 A/Sq mm. inclusive of Insulators, colour coded Heat shrinkable Insulation sleeve (RYBN) |
| 55 | Assembly of Hardware (PVC Channels/MCB Channels/Fibre-Glass/Gaskits /nuts/Bolts/ washers / Terminal blocks, etc) |
| 56 | Complete Wiring inclusive of control wiring, power wiring, Aluminium Solid connections/interconnections including insulators, thimbles,etc |
| 57 | Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel. |
| 58 | Comprehensive Maintenance charges (24 hrs x 7days) for Air Conditioning system including (routine and preventive maintenance with parts including consumables such as gas, oil, filters) and break down maintenance of high & low side of the air conditioning plant and fire fighting system comprising of all the machinery including motors, pumps, compressors, coil and all other parts including replacement of same free of cost during three years after expiry of Two year defect liablity period. |
| 59 | Total Capital Cost : SH-1 |
| 60 | 1st Year (Free of cost Comprehensive maintenancve with parts) (Qty. 1 job/per) |
| 61 | 2nd Year (Free of cost Comprehensive maintenancve with parts) (Qty. 1 job/per) |
| 62 | 3rd Year (1.5% of Total actual work done ) |
| 63 | 4th Year (Mtc. Charges of 3rd year + 10% ) |
| 64 | 5th Year (Mtc. Charges of 3rd year + 10% ) Please Enable Macros to View BoQ information |