| 1 | SRTC of indoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for Gym, health club, swimming pool , admin building, badminton court, gust house and AC of club , card room , billyyard and bar )A) INCOMERi) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-3 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 8 Nos. |
| 2 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for cricket ground high mast)A) INCOMERi) 400 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 250/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 600 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 Nos.ii)ii) 16 AMP DP MCB,10KA -2 Nos. |
| 3 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for jogger park )A) INCOMERi) 200 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 200/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 375 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 2 No.iii) 32 AMP DP MCB,10KA -2 Nos.iii) 16 AMP SP MCB,10KA -1 Nos. |
| 4 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for gym , sauna steam, change room of swimming pool )A) INCOMERi) 250 Amps FP MCCB (36KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 400/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 400 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 100 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C having overcurrent and short circuit protection- 4 No.ii) 63 AMP FP MCB,10KA -3 Nos. |
| 5 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (forswimming pool plant room)A) INCOMERi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 150/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 200 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 7.5 HP DOL starter - 2 No.ii) 5 HP DOL starter - 1 No.iii) 40 AMP FP MCB,10KA -1 No.iv) 40 AMP DP MCB,10KA -2 No. |
| 6 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for lawn tennis clay court)A) INCOMERi) 160 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 160/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 200 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 AMP FP MCB,10KA -4 Nos. |
| 7 | SRTC of outdoor type cubical Feeder pillar(With 900 mm stand made out of 40x40x5 mm thick angle iron framework), fully compartmentalized made out of 2 mm thick CRCA Sheet having IP55 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder painted of approved shade, suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick MS sheet with knock outs of different size cables as required for incoming and outgoing cables entry, erected on cement concrete foundation, Brick work & plaster for covering all sides complete with painting with 2 or more coats of exterior paint after making the surface smooth with Birla putty, connections & interconnections, earthing etc complete as required. (for TT panel )A) INCOMERi) 125 Amps FP MCCB (25KA) with thermomagnetic release for O/L+S/C-1 Nos. ii) calibrated Intelligent multifunction digital panel meters of class 0.5S accuracy with communication interface port RS 485 for recording Voltage (Between Phases and between each phase and neutral), Current (In each Phase and neutral), KVA, KW, KWhr, KVAR, pf, 64 samples/cycle, Total harmonic distortion, with suitable rating 63/5 amps CTs etc. complete with wiring , connections etc. iii) 6 Nos. Phase indication LED lamps with 2 Amp back up MCB, breaker 'ON/OFF' indicating light with 2A MCB, test terminal block set, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required. B) BUSBARSi) 100 Amps TP&N Aluminum bus bars mounted on SMC supports.( Extension type )C) OUTGOINGSi) 63 AMP FP MCB,25KA -2 No.ii) 32 AMP FP MCB,10KA -1 No. |
| 8 | SRTC of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling onlya)1.5 TR with 5 Star BEE Rating |
| 9 | 2.0 TR with 5 Star BEE Rating |
| 10 | Earthing with GI earth pipe 4.5 meter long, 40mm dia including accessories, and providing masonry enlosure with cover plate having locking arrangment abd watering pipe etc with charcoal/coke and salt as required. Please Enable Macros to View BoQ information |