| 1 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 2 | Providing and fixing aluminium work for doors, windows,ventilators and partitionswith extruded built up standard tubularsections/ appropriate Z sections and other sections of approvedmake conforming to IS: 733 and IS : 1285, fixed with rawl plugs andscrews or with fixing clips, or with expansion hold fastenersincluding necessary filling up of gaps at junctions, at top, bottomand sides with required EPDM rubber/ Neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred andjointed mechanically wherever required including cleatangle,Aluminium snap beading for glazing / panelling, C.P. brass /stainless steelscrews, all complete as per architectural drawingsand the directions of Engineer-in-charge. (Glazing and panelling tobe paid for separately): |
| 3 | For fixed portion |
| 4 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 5 | For shutters of doors, windows & ventilators including providing andf ixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately). |
| 6 | Anodised aluminium (anodised transparent or dyed to requiredshade according to IS: 1868, Minimum anodic coating of grade AC15) |
| 7 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade 1 Type II in panelling fixed in aluminium doors, windows shutters and partition frames with C.P brass/stainless steel screws etc. complete as par architectural drawing and directions of engineer-in-charge. |
| 8 | Pre-laminated particle board with decorative lamination on both |
| 9 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 10 | With float glass panes of 4.0 mm thickness |
| 11 | Providing and fixing aluminium handles, ISI marked,anodised(anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour or shade with necessaryscrews etc. complete : |
| 12 | 125 mm |
| 13 | Providing and fixing aluminium sliding door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete : |
| 14 | 250x16 mm |
| 15 | Providing and fixing aluminium tower door bolts ISI markedanodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nutsand screws etc. complete : |
| 16 | i)200 x 16 mm |
| 17 | Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead. |
| 18 | For thickness of tiles above 10 mm and upto 25 mm |
| 19 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceablematerialwithin 50 metres lead as per direction of Engineer-in-charge. |
| 20 | In Cement mortar |
| 21 | Disposal of building rubbish / malba / similar unserviceable,dismantled or waste materials by mechanical means, includingloading, transporting, unloading to approved municipal dumpingground or as approved by Engineer-in-charge, beyond 50 m initiallead, for all leads including all lifts involved. |
| 22 | ProvidingandfixingM.S.grillsofrequiredpatterninframesofwindowsetc.withM.S.flats,squareorroundbarsetc.includingpriming coat with approved steel primer all complete. |
| 23 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 24 | Half brick masonry with Ist class common burnt clay F.P.S.(nonmodular)bricks in superstructure above plinth level upto floor V level in |
| 25 | Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 26 | 12 mm cement plaster of mix: |
| 27 | 1:4 (1 cement : 4 fine sand) |
| 28 | 15 mm cement plaster on rough side of single or half brick wall ofmix:- |
| 29 | 1:4 (1 cement : 4 fine sand) |
| 30 | Steel work in builtup tubular (round, square or rectangular tubes etc.)trussesetc.,including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. |
| 31 | Hot finished welded type tubes |
| 32 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)with zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto12 metre or as desired by Engineer-in charge. The sheet shall befixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with |
| 33 | Precoated galvanised iron profile sheets 0.40 mm thick |
| 34 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and makinggood the walls wherever required: |
| 35 | White Vitreous China Flat bacfowash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 36 | Providing and fixing P.V.C.waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 37 | Flexible pipe |
| 38 | 32 mm dia |
| 39 | Providing and fixing white vitreous china pedestal type watercloset (European type W.C. pan) with seat and lid, 10 litre lowlevel white P.V.C. flushing cistern, including flush pipe, withmanually controlled device (handle lever), conforming to IS :7231, with all fittings and fixtures complete, including cuttingand making good the walls and floors wherever required : |
| 40 | W.C. pan with ISI marked white solid plastic seat and lid. |
| 41 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tubeupto 1 metre long with S.S. triangular plate to Eureopean typeW.C. of quality and make as approved by Engineer - in - charge |
| 42 | Providing and fixing C.P. brass angle valve for basin mixer andgeyser points of approved quality conforming to IS:8931 |
| 43 | 15 mm nominal bore |
| 44 | Providing and fixing C.P. brass long body bib cock of approvedquality conforming to IS standards and weighing not less than 810 gms. |
| 45 | 15 mm nominal bore |
| 46 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 47 | 45 cm length |
| 48 | 15 mm nominal bore |
| 49 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame ofapproved make and shade with 6 mm thick hard board backing : |
| 50 | Rectangular shape 453x357 mm |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 52 | Internal work - Exposed on wall |
| 53 | 20 mm nominal outer dia Pipes |
| 54 | 25 mm nominal outer dia Pipes |
| 55 | Providing and fixing C.P. brass bib cock of approvedquality conforming to IS 8931 |
| 56 | 15 mm nominal bore |
| 57 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with sealring conforming to IS :5382 leaving 10 mm gap for thermalexpansion, (i) Single socketed pipes |
| 58 | 75 mm diameter |
| 59 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank, IS : 12701 marked, with cover and suitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 60 | Steel work welded in built up section/framed work including Cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 61 | In grating, frames, guard bar, railing, brackets, gates and similar works. |
| 62 | Providing modular laboratory tables,cabinets, shelve (including all materials- MDF boards, standard door handles, baskets, hydraulic drawer channels, hydraulic hinges, material transport, labour charges all complete |
| 63 | Providing and fixing 18mm thick gang saw cut . mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 64 | Granite of any colour and shade |
| 65 | Area of slab over 0.50 sqm. |
| 66 | Brick work with 1st class common burnt clay F.P.S.(non modular) bricks in superstructure above plinth level upto floor V level in all shapes and sizes in: |
| 67 | Cement mortar 1:4 (1 cement: 4 coarse sand) |
| 68 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposalof surplus excavated soil as directed, within a lead of 50 m. |
| 69 | All kinds of soil. |
| 70 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m |
| 71 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 72 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 73 | Suspended floors, roofs, landings, balconies and access platform |
| 74 | Brick work with Ist class common burnt clay F.P.S.(nonmodular) bricks in foundation and plinth in: |
| 75 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 76 | Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in -All work upto plinth level: |
| 77 | 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 78 | 1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) |
| 79 | Reinforcement for R.C.C. works including bending, binding and placing in position. |
| 80 | Thermo-Mechanically Treated bars |
| 81 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with |
| 82 | 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 83 | Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 84 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. |
| 85 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 86 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 87 | Two coat |
| 88 | Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours White, Ivory, Grey, Fume Red,, Brown, laid on 20mm’ thick cement mortar 1;4 (1 Cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete. |
| 89 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive), as per IS: 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers Of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre; to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.l. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.l. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compoundjointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 90 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I, |
| 91 | Providing and fixing 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. |
| 92 | 0.63mm thick with zinc coating not less than 275gm/m2 |
| 93 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 94 | Using M.S. angels 40x40x6 mm for diagonal braces. |
| 95 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter |
| 96 | 30 mm thick |
| 97 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat |
| 98 | Frame size 45 x 70 mm Please Enable Macros to View BoQ information |