| 1 | Providing of Split type High wall 2.00 TR (rated cooling capacity should not be less than 6,000 Kcal/ hr or 24000 BTU/hr or 7000 W) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of pure copper) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 11.0 ampere, including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power Top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. |
| 2 | Providing of Split type High wall 1.50 TR (rated cooling capacity should not be less than 4500 Kcal/ hr or 18000 BTU/hr or 5250KW) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of copper pipe) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 8.50 ampere including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power Top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. |
| 3 | Standard installation of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. |
| 4 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. |
| 5 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 TR & 2 TR ac) beyond the standard length as per direction of the Engineer-in-Charge. |
| 6 | Providing hard UPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. |
| 7 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. |
| 8 | General Servicing of 1.5/2.00 Tr capacity split AC machines in/c washing cleaning of ( Indoor & Outdoor) units both by pressurised water by using Jet pump and servicing Jacket as per direction of the Engineer-In-Charge.. |
| 9 | Providing & Fitting fixing of Capacitor-4 µf as per the direction of the Engineer-in-charge.. |
| 10 | Providing & Fitting fixing of Capacitor-36 µf as per the direction of the Engineer-in-charge |
| 11 | Providing & Charging of Non CFC Refrigerant gas to Split AC as per the direction of the Engineer-in-charge.. Please Enable Macros to View BoQ information |