| 1 | Demolition of reinforced cement concrete as in cover slabs and walls, basement walls and in foundation all as specified and directed . |
| 2 | Material and labour for providing precast RCC cover slab (1:2:4) type B-1 (for man holes, drain cover etc) (using 20mm graded stone aggregates) including necessary use and waste of formwork and set in CM (1:6) complte with joints to match complete all as specified and directed. |
| 3 | Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hooping for columns,plinth band, lintels etc hooking ends and binding with a including mild stell wire (annealed) not less than 0.90mm dia or securing with clips quality conforming complete all as specified and directed. |
| 4 | Material and labour for 400x400x12mm thick premium quality tiles hi-traffic range of endura full body vitrified with anti skid finish,square in shape, laid in floor/pavings set and jointed on screed bed of 40mm thick in Cement mortar 1:4 complete fixed in repair wth and including demolition of existing tiles of any description inclding bedding layer /PCC etc as ordered as per site requirement and disposal of debries from sitecomplete all as specified and directed. |
| 5 | Demolition of brick or stone masonry work, built in cement mortar incl all quoinns, arches, pillars etc but excluding ashlar facings, dressed stone work complete all as specified and directed. |
| 6 | Material and labour for brick work with sub class 'B' old size bricks straight or curved on plan exc. 6m mean radius built in cement mortor (1:6) and including taking out roots ,of bushes/vegetation groth upto 120 cm complete all as specified and directed. |
| 7 | All as per serial item No 06 above except bricks complete all as specified and directed |
| 8 | Material and labour for PCC (1:2:4) Type B-1using (20mm graded stone aggregate) as in bed blocks, hold fasts and coppings as in brick wall duly rounded or chamfered on edges and finishing on roof surface / chajja (thickness of concrete will be provided as per site requirement up to five storey incl necessary sccafolding and demolition of PCC and dispose of the material from MoD land complete all as specified and directed. |
| 9 | Taking down existing plaster of any description on brick wall/ concrete surface in facia,chhajjas,balconies,roof/ceiling at any floor (upto G+3) including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 10 | Material and labour for rendering 15mm thick in CM (1:4) on fair faces of brick/concrete surfaces of walls mixed with water proofing compound including two coats of interior emulsion paint with necessary prepartion to newly pastering surface and finished fair and even (without using extra cement )and ncluding taking out roots ,of bushes/vegetation groth upto 120 cm complete all as specified and directed. (Note : WPC shall be measured and paid for separately and the rates quoted in this item are inclusive of providing necessary scaffolding and other requisite arrangements , cost of T&P , all safety devices etc complete.) |
| 11 | Integral waterproofing compound complete all as specified and directed. |
| 12 | Dismantling of wrought iron mild steel work of any description or from any position complete all as specified and directed. |
| 13 | Fixing only of framed work such as grills, gratings etc wth ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred ,iron doors,Ms Plain sheet, XPM, ladders, framed balusters, walk way, railings, framedwork of water tanks and similar work confirming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 14 | Taking down carefully existing grill (of any description) from walls/compound wall of any height by demolition the portion of embedded PCC or brick work and refixing the same in same/other location as ordered as per site requirement complete all as specified and directed. NOTE:- PCC for embedding in refixing shall be paid separately under appropriate item herein |
| 15 | Material and labor for preparation of steel surfaces of old or new, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and directed. |
| 16 | Material and labour for pre polished machine cut kota stone slab flooring, 15-18mm thick in (single piece), in riser and treads and landings of stairs and step, skirting & dado in repair over and including 20mm thick cement screed in Cement Mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rounding and moulding edges and corners allaround and polishing to match with existing in Blgs up to G+3 complete all as specified and directed. |
| 17 | Supply and fixing for repair wall panelling of plastic vinyl composite of size 3050 x 300 x 8 mm thick with wooden/plane surface waterproof , termite proof, chemical resistant of light weight fixed with wooden screw with rawl wall plug complete all as specified and directed. |
| 18 | Supply and fixing in repairs wooden flooring (make signature) size 1215 x 195 mm and thickness 8.3 mm direct pressure laminated according to EN 13329 for glueless installation heavy domestic and light commercial use EN 13329 lavel of use 22 including under layer of 2 mm EP and polythene layer complete all as specified and directed. |
| 19 | Material and labour for POP false ceilig includng GI framing, main member C shaped spacing not exc 1m c/c having weight 300 to 350 gm per RM and cross member U shaped spacing exc 500 mm c/c having weight 250 to 300 gm/RM and C section fixed on parameter wall with screws and rawl plug including hanging arrateement to RCC slab/shade wth L shape member exc 105 m (wieght not less tha 120 gm/RM) and wire mesh of dia 0.50 to 0.56 mm weight not less than 350 gm/sqm fixed with steel screws of GI framing and applying two coat of luxury emulsion (Royal) complete all as specified and directed. Note : only flat surface to be measured) |
| 20 | Supply and fixing for 16 to 18 mm thick granite stone slabs mirror polished of colour and shade as approved by GE, machine cut bedded & jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone fixed as in steps, jambs, pillars window cills, cooking platforms & the like over a scree bed of 15mm thick CM 1:6 etc complete all as specified and directed |
| 21 | Rounding to edges of stone slabs one edge , such as in steps , cooking platform , and other similar situations complete all as specified and directed |
| 22 | Material and labour for vitrified ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm( 600 x 600 ) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement incl screeding 15mm thick in CM 1:6, complete including Dismantling floor, stone, hearth or wall tiling/terrazo/sotne slab including cement mortar bedding complete or in patches and removing rubbish off the premises complete all as specified and directed. |
| 23 | All as per serial item No 22 but as in vertical surfaces incl plastering 10mm thick in CM 1:4 complete all as specified and directed |
| 24 | Material and labour for 15 mm thick redering on fair faces of concrete surfaces in CM 1:4 with water proofing compound @ 200ml per 50 Kg of cement and incl demo of old plaster on concrete surface over roof surface up to five storey and dipose off the waste material from MoD lad complete all as specified and directed.NOTE:- WPC shall be measured and paid for separatly) |
| 25 | Material and labour for liquid water proofing tratement on roof/terrace/chajja surface and applying three coats of fiber reinforced elastomeric liquid water proofing treatment incluing crack seal treatment as per site requirement, formulated with select elastomeric and resilient acrylic polymers and reinforcing polyester fiber, upon curing, forms a thick seamless, durable treatment. Apply self priming coat with 33% of water dilution in a verticle or horizontal surface. Treatment should be viscous liquid apprearence, colour white and applied:- (a) Apply first coat of the material shoulde be apply in both direction of surface without dilution to achieve a forced system coverage of 0.93 sq metre per liter. Allow it to dry for 4-6 hours between coats. (b) Apply second coats without dilution to achieve the forced system coverage of 1.20 sqm per liter on perviously painting surface with high quality. Allow it to dry for 4-6 hours between second and third coats. (c) Apply Third coats without dilution to achieve the forced system coverage of 2.32 sqm per liter on perviously painting surface with high quality. Note :- Executive as per manufacture instruction including scaffolding, trestles, ladders cradles and necessary safety measures complete all as specified and directed . Make Asian Paint (Smart care Damp proof) or equivelent of BERGER/SHALIMAR. |
| 26 | Dismantling of GI barbed wire fencings fixed in RCC/Steel fencing posts complete all as specified and directed. |
| 27 | Supply and fixing for GI 2 standed barbed wire2.24mm dia wire with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire. staples or steel pins etc (Each line wire to be measured) complete all as specified and directed. |
| 28 | All as per serial item No 27 but except barbed wire complete all as specified and directed. |
| 29 | Supply and fixing in repairs for concertina coil 2.64mm dia having a core wire high carbon spacing steel of high tensile strength as per grade of IS-4454 (Pt-I) with a low carbon steel strip punched tape 19mm wide, 0.5mm thick and series of knife edge sharp barbs/blades @ 25mm centre to centre punched all along the length on both the sides of strips at regular interval confirming to IS-513 complete all as specified and directed. |
| 30 | Dismantling of plain or corrugated steel sheeting any gauge and thickness including Nainiital or similar pattern roof coveriong complete all as specified and directed. |
| 31 | Material and labour for fixing of 1 to 2 mm thick fibre glass reinforced translucent plain/corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed including dismantling. |
| 32 | Material and labour in repair for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc.,of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. (Note : Gauge and size for stainless steel pipe to be apporved by GE as per site requirement). Please Enable Macros to View BoQ information |