| 1 | Supply & installation 15 meter high galvanized mast light suitable for 6 to 9 lanternsymmetrically fitted alongwith their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike, flexible copper wire including RCC foundation as per height |
| 2 | Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 3 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed |
| 6 | Supply & lay in trenches double walled corugated HDPE pipe 50 mm dia high density for protection of under ground cables( Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted) |
| 7 | Supply and fix, test, commissioning of LT weather proof panel board powder coated in door type double door shutter, out door type made out of CRCA 3 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outoor, floor mounting type with closed bus bar, chamber and with Copper bus bar of cap 200 Amp with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digitalammeter 0-500A, digital voltemeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y- B.selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable minimum 60 cm above ground level of legs of angle iron) size of cable glands, cable lugs,nut, bolts, washers etc. The bottom portion of enclosure shall beshall be minimum 60 cm above ground level of legs of angle iron a) Copper bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & 100 Amps for neutral -1 Nob) MCCB 4 Pole 100 Amps 25 KA - 1 No (I/C) c) MCB TPN 63 Amp, 10 KA-01 No(O/G)d)MCB TPN 32 Amp, 10 KA-01 No(O/G)e)TIME Swith daily dial type FM 1/ Quartz daily 240 V din mounting Make L&Tf) Contactor 40 A, 3 pole, MNX 40 make L&T |
| 8 | S&F in repair Tubes \\"light grade\\" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 50 mm diabore complete all as |
| 9 | S&F in repair Tubes \\"light grade\\" galvanised iron, laid under roads/drain, fixed to poles, walls, with flat iron clamps bolts/nuts/washers of the following sizes of 40 mm diabore complete all as |
| 10 | Dismantling existing unserviceable / damaged LT Pole complete all as specified and directed. |
| 11 | Taking down existing defective LT under ground cable of any size from trenches complete all as directed |
| 12 | Supply, Laying, jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ ducts or fixed to poles/ walls or laid under roads/ paths/ drains/ culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following size:- |
| 13 | 4 core, 16 sqmm |
| 14 | 4 core, 25 sqmm |
| 15 | 2 core, 10 sqmm |
| 16 | Supply, install & errect in true vertical posision galvanised steel octagonal poles 7 meter long with side mounted decorative type single arm /double arm (as required on site) bracket for mounting street lights of 3 mm thick sheet, bottom dia 130 mm and top dia 70 mm finial tapered complete with MS base plate of size 220mmx 220mmx12mm, foundation bolts, nuts, washers & screws. The poles shall be hot dip galvanized as per relevant Indian standards with average coating thickness of minimum 70 micron. the material of pole HT Steel Conforming to grade S355JO & that of base plate is Fe 410 conforming to IS 226 / IS 2062. The Octagonal Poles shall be in single section. There shall not be any circumferential weld joint. Pole drawing along with details of base plate, foundation bolts and foundation details (RCC) shall be submitted along with pole including taking down old us poles of any type as directed.(Note: excavation, RCC foundation as per manufacturer drawing & specification, foundation bolts with nut & washers, Decorative type single arm for mounting street light, connector block for 3phase+ 1nutral for cable termination & MCB SP 10 Ams & pole cap is deemed to be included in rate quoted) |
| 17 | S&F in replacement new Endura cityliner Neo 70 Watt LED Luminaries lense embaded PC cover with high power LED as light source of 70W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) |
| 18 | S &F in replacement Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole / wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 12 KW equally distributed over 3 Phase (4KW /Phase). Model No- 02EC12KW3P, Contactor Rating : 40 Amps (AC3), MCB (single-pole) Rating :63 Amps 3 Nos. Make : Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad or Equivalent of Bajaj /L&T/Legrand |
| 19 | M&L earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of strata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. |
| 20 | Cutting through existing bituminous road /PCC/ floor/ approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing / RCC pipe/ HDPE pipe for encasing of cable and repairing the road to match with the original finish complete all as specified. |
| 21 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanised earth lead wire 4.0 mm dia by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil/stata, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and indicated including testing on completion NOTE: 1.The unit rate includes earth strip/GI lead wire and protection pipe upto (maximum 7.5 metre) from earth plate to earth point/test point. 2. unit rate includes the rate of excavation and earth work. |
| 22 | Supply and fixing, testing, commissioning of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B,selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of the panel should not be less than 45cm) a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 200 Amp - 1 No (I/C Main)c) Onload changeover switch 250 Amp- 1 Nod) MCCB 4 pole 25 KA,125 Amp-1 No Out goinge) MCCB 4 pole 63 Amp16 KA- 2 Nos out goingf) MCCB 4 pole 100 Amp 25 KA -1 Nog) MCB SPN 32/40 Amp -2 Nos out going |
| 23 | Supply and fix in repair 4 Ways sheet metal enclosure DBs SPN, 240V with 200 Amps rated bus bars double door complete all as specified and as directed. |
| 24 | Supplying, install and errect in true vertical position steel tubular swaged welded pole complete with cast iron/MS base plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-31 (9.0 metre long) LT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting pole No the black paint by stenciled letters /figures of 8 cm height complete all as specified and directed by Engr-in-charge. (Note:1. Excavation and PCC works will be measured and paid separatly in respective items.) |
| 25 | Supply and fixing LED solar street light fitting 40 watt Havells Enviro ALL IN ONE with High efficiency Mono Crystalline solar PV Module, Lithium Ferro Phosphate battery with in built BMS technology, High Efficacy LED, MPPT solar charge controller & Aluminium Extruded body. ALL-IN-ONE SSL is specially designed by Progressive Intelligent Dimming which automatically control the dimming and brightness of light, which increase the backup time.Product code SOLAR AIO 40W 60 WP 12.8 V, 24 Ah, Colour Temp( CCT) 5700 KSystem Lumens(lm) 6512 lm all as specified and directed by Engineer in charge |
| 26 | Excavating in post hole size 0.6 Mtr X 0.6 Mtr X 1.65 Mtr depth for installation of LT pole for solar, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm complete all as specified and directed. |
| 27 | M & L for cement concrete 1:3:6 type C-1 using 20 mm graded aggregate incl necessary form work for coping of poles etc all as specified and directed. |
| 28 | M&L for cement concrete 1:4:8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed. |
| 29 | M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified and directed. |
| 30 | M&L for cutting steel tubing to required length for insertion of new Tee Branches, reducer in any position of 15mm dia pipe line complete all as specified and directed. |
| 31 | S&F in sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 10 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed. |
| 32 | S&F tubes, 'medium grade', galvanised, with all fitting; for fixing concealed in wall complete of 15mm dia with complete fitting and fixture complte all as specified and directed. |
| 33 | S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of cap 15mm dia complete all as directed |
| 34 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as directed |
| 35 | S&F PVC connection 15 mm size for cold water with PTMT nuts of length 450 mm complete all as specified and directed. |
| 36 | S&F CP connection 15 mm size with for hot water with PTMT nuts of length 450 mm.complete all as specified and directed. |
| 37 | S & F Geyser 25 Ltrs, vertical mount, 5 star rated, glass line coated tank with adjustable thermostat, suitable for, 230 volt, 2 KW, 50 Hz electric supply. |
| 38 | S&F stop valves 15 mm bore CP With crutch or butterfly handle, screwed both ends for iron pipe or unions, complete all as directed. |
| 39 | Material and labour for point wiring with two runs of stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLSH cable in and including PVC casing capping of suitable size including provision of PVC modular type terminal boxes of suitable size including fixing modular type switches / sockets / regulators / AC starters in and including cover plate etc fixed in wall with brass chromium plated screws and cap washer complete with one single core continuous 1.5 Sqmm, FRLSH copper cable for earth wire for One Ceiling fan/ Exhaust fan point controlled by one switch complete all as specified and as directed. |
| 40 | Supply and fixing ceiling fan complete with blade, down rods, and all accessories 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.0 BEE, five star rated with brushless direct current motor (BLDC) |
| 41 | S&F Exhaust fan plastic body 200 mm sweep, single phase 230 volts with all accessories including frame work in ply wood/ metal in existing window / wall and necessary electric connection all as specified and directed Make: Havells /Bajaj /CG/Usha |
| 42 | Material and Labour for cutting existing wall/window and making of hole for fixing pvc body exhaust fan of 200 mm sweep including frame work for fixing exhaust fans & finishing work match with existing surface all as specified and directed. |
| 43 | M & L for ceiling rose of size 65 X 25 mm surface Bakelite three terminals complete all as specified and as directed |
| 44 | M&L for Modular type switch, 1 way,6 Amps, 1 module all as specified and directed |
| 45 | Supply and fix down rod of medium grade GI tubing 15mm bore, 600 mm length ( 2feet), having holes and threading at ends as per site requirement complete all as specified and as directed |
| 46 | Supply and fix down rod of medium grade GI tubing 15mm bore, 1200(4 feet) mm length, having holes and threading at ends as per site requirement complete all as specified and as directed |
| 47 | Supply and fix down rod of medium grade GI tubing 15mm bore, 3000 mm(10 Feet) length, having holes and threading at ends as per site requirement complete all as specified and as directed |
| 48 | S & F Electronic step regulator (Modular type) (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep 100 watts |
| 49 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1 Ton |
| 50 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton |
| 51 | Supply and fix in replacement MCB SP 6 to 32 Amps, 240 volts complete all as specified and as directed. |
| 52 | S&F MCB, SP-240 volts, breaking capacity 10 KA, rating 20 to 32 amps, complete all as specified and as directed |
| 53 | Supply and fixing PVC insulated flexible cable 3 core with multi stranded copper round shaped sheathed for 1100 volts grade 4 sqmm |
| 54 | Supply and fix copper pipe of size 2\\"-3\\" suitable for 1 Ton split Air conditioner |
| 55 | Supply and fix stand/ mounting bracket metal body fully powder coated factory made for outer unit of split air condioner 1/1.5 Ton |
| 56 | Note: Amount of sch of credit of Rs.21670/-will be deducted from total amount of BOQ. Please Enable Macros to View BoQ information |