| 1 | Supplying, installing, testing and commissioning of 250 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 750 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.As per electrical D.S.R 2022-23 /4-5-7 |
| 2 | Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & testcertificate from manufacturer erected on provided M.S. box and connected to CTs.. As per electrical D.S.R 2022-23 /6-3-5 |
| 3 | Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. .As per electrical D.S.R 2022-23 /6-3-15 |
| 4 | Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. As per electrical D.S.R 2022-23 /6-5-2 |
| 5 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI .As per electrical D.S.R 2022-23 /9-1-5 |
| 6 | Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP. As per electrical D.S.R 2022-23 /9-2-2 |
| 7 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with ituminous paint with joints required. no EA-EP. As per electrical D.S.R 2022-23 /9-2-3 |
| 8 | Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete As per electrical D.S.R 2022-23 /16-1-7 |
| 9 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL As per electrical D.S.R 2022-23 /7-1-24 |
| 10 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. As per electrical D.S.R 2022-23 /9-3-1 |
| 11 | Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010 As per electrical D.S.R 2022-23 /6-1-14 |
| 12 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs) As per electrical D.S.R 2022-23 /5-7-20 |
| 13 | Supplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawout type, 650V, 800A, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/ hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB As per electrical D.S.R 2022-23 /5-8-2 |
| 14 | Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB As per electrical D.S.R 2022-23 /5-5-4 |
| 15 | Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 400A incoming and 12 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.As per electrical D.S.R 2022-23 /5-7-16 |
| 16 | Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included). For Solar Panel Structure pole muffing or any other purpose.As per electrical D.S.R 2022-23 /16-3-5 |
| 17 | Providing and fabricating structural steel work in rolled sections like joists, channels,angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. ( Purpose for Solar Structural Steel Work) As per Civil D.S.R 2022-23 /Sr.no 816/23.01/BDC 2 |
| 18 | Providing hot dip galvanizing conforming to IS 12594-1988 to reinforcement bars, having mass of zinc coating shall not be less than 610 grm/ One Square Metre of bar surface area factory control process with Degreasing, Rinsing, Acid Pickling, Again Rinsing after picking, Fluxing, Hot Dip Galvanizing in molten Zinc bath Having Zinc purity of bath minimum 98.5% Quenching & Passivation Process. 16 to 25 mm dia with prior approval of concerned Superitending Engineer.As per Civil D.S.R 2022-23 /Sr.no 1742/50.21 /IS 12594-1988 |
| 19 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDP for enclosing cable below ground/road surface, to required depth complete..As per electrical D.S.R 2022-23 /7-6-9 |
| 20 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. As per electrical D.S.R 2022-23 /7-6-5 |
| 21 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories. As per electrical D.S.R 2022-23 /7-11-1 |
| 22 | Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided onduit /trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW .As per electrical D.S.R 2022-23 /1-3-4 |
| 23 | Land leveling, Grading, Gravel and Dressing Market Rate |
| 24 | O & M including periodic cleaning support panels from dust panels with water cleaning 1-year basic Please Enable Macros to View BoQ information |