| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | M&L for earth work in excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in soft/ disintegrated rock and getting out all as specified and directed. |
| 6 | All as per ser item no 4.00 here-in before but depth exc. 1.5 m but n exc 3.0 m complete. |
| 7 | Surface dressing n exc 15 cm deep in hard dense soil complete all as specified and directed. |
| 8 | M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete (design mix) M-35 (using 20 mm graded stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete (design mix) M-25 (using 20 mm graded stone aggregate) columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 11 | M&L for reinforced cement concrete (design mix) M-25 (using 20 mm graded stone aggregate) Beams, bands, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed. |
| 12 | Use & waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surface flat with fair finished surfaces complete all as specified and directed. |
| 13 | Use & waste for Formwork sides of pillars, posts, struts, piers, columns and stanchions.; vertical or to batter surface flat and fair finished surfaces complete all as specified and directed. |
| 14 | Use & waste for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc..; vertical or to batter surface curved and fair finished surfaces complete all as specified and directed. |
| 15 | Use & waste for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc..; vertical or to batter surface flat and fair finished surfaces complete all as specified and directed. |
| 16 | Use & waste for Formwork to cornices and mouldings of any shape in cross section and of any girth flat and fair finished surfaces complete all as specified and directed. |
| 17 | M&L CRS (Corossion Resistance steel) TMT reinforcement bars 10mm and over, cut to length, bent to shape as required including cranking bending, spirally for hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia or securig with clips etc complete all as specified and directed. |
| 18 | All as per item no 16.00 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders round bars complete all as specified and directed. |
| 19 | M&L for modular size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed |
| 20 | M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces or brick masonry surfaces or surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 22 | Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, complete all as specified and directed. |
| 23 | Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n. exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. |
| 24 | M&L for preparation of newly plastered or unplastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion (100% acrylic) over a coat of compatible primer complete all as specified and directed. |
| 25 | S &F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 26 | M&L for prepration of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 27 | M&L for 16-18mm thick, Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size not exceeding 0.25 sqm fixed with and including, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment complete all as specified and directed. |
| 28 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed |
| 29 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 30 | S&F of stainless steel work of size 40cm high and 25 cm width and sheet thickness not less than 1mm with necessary fixtures including screw and sealing compound on wall height upto 7m complete as specified and directed |
| 31 | S&F of Stainless steel words of size 50cm high and 35 cm width and sheet thickness not less than 1mm with necessary fixtures including screw and sealing compound on wall height upto 7m complete as specified and directed |
| 32 | S&F of traditional stone canopy with kalash top made from red sandstone of thickness 50mm thick including all moulding, cutting and size as per drawing complete all as specified and directed. |
| 33 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed. |
| 34 | M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 35 | M&L for providing of un-reinforced precast concrete cable cover class LV, Type 1 size 250mmx 150mm x 40mm laid flat dry for protection of under ground cable complete all as specified and directed. |
| 36 | M & L for making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded stone aggregate to match with existing surfaces all as specified and directed. |
| 37 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm 4 core all as specified & directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule) |
| 38 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 core all as specified & directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item. |
| 39 | M & L GI Tubing \\"light grade\\" galvanized for protection LT Cable all as specified of size 40 mm bore complete all as specified and directed by Engr-in-Charge. |
| 40 | Supply & fix, testing & commissioning for outdoor bus bar box size 650 x 650 x 400 mm fabricated out of 3.15 mm thick MS Sheet having 4 Nos closed aluminium bus bar chamber of capacity 200 A (including necessary insulator) suitable for 3 phase & neutral, 4 wire 50 Hz AC, 415V with minimum eight out going and adjustable thermal & adjustable magnetic 36KA 63 amp TPN Ics= Icu 75 % at 415 volt as incomining system including red,blue & yellow LED indication lamp and both side openable hinged cover with proper locking arrangement ,outdoor type weather proof with angle iron of size 50x50x5 mm(including painting of angle iron) outoor, floor mounting 100 cm above ground level grouting including making PCC 1:2:4 type B-1 using 20 mm graded course aggregate with complete plastering & white wash etc also includes provision of suitable size of cable glands,cable lugs,nut, bolts,washers etc for fixing of cable with the bus bar.The bottom portion of enclosure shall be minimum 90 cm above ground level of legs of angle iron all as specified and directed. |
| 41 | S & F in replacement sheet metal enclosure, double door type surface mounted concealed in wall 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. |
| 42 | S & F MCB SP suitable for 240 volts, AC supply 6 to 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 43 | S & F MCB TPN suitable for 415 volts, AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. |
| 44 | S&F of PVC insulated PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 230 V complete all as specified and directed. |
| 45 | S&F non metalic heavy grade PVC conduit ISI marked of size 20mm dia incl all accessories complete all as specified and directed. |
| 46 | S& F of flexible LED Strip uses high brightness SMD LED as the light source for indoor application luminaire 24 watt, 220 V AC with high effeciency light complete with driver , holder and LED Lamp suitable for roof , ceiling including connecting up with 3 core flexible copper conductor cable of suitable size complete all as sfecified and as directed . Note:- Cat part no LHEHDLPFUN1W024(Flexion Neo LED Strip 24 W of anycolour) of Havells or eluivalent Bajaj/C&G/Phillips/as approved by GE. |
| 47 | S&F of integral Industrial LED flood light luminaire of 120 W, robust highbay luminares with highefficacy of min system efficacy 120 lm/W with toughened glass as per IS-16107, IP-66 and IK07 degree of protection with pressure diecast alluminium housing and toughened glass and THD <10%, PF >0.95, 5700-6500 K colour temperature, CRI 70 ,HV Cut off @ 320V/Low V Cut with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 3 core minimum 2.0 m length, on pole inclduing testing and with LM 79 and 80 report with NABL certified lab and NABL certificate complete all as specified and directed. |
| 48 | S&F of integral Industrial LED flood light luminaire of 50 W, system efficacy 110 lm/W with toughened glass as per IS-16107, IP-66 and IK07 degree of protection with pressure diecast alluminium housing and toughened glass and THD <10%, PF >0.95, 5700-6500 K colour temperature, CRI 70 ,HV Cut off @ 320V/Low V Cut with all fixing arrangement, nuts, bolts, washer and clamps for fixing and connecting to electric system with 2.5 sqmm PVC aluminium stranded conductor 3 core minimum 2.0 m length, on pole inclduing testing and with LM 79 and 80 report with NABL certified lab and NABL certificate complete all as specified and directed. |
| 49 | Supply and fixing of 6W warm white decorative wall led lighgt 1 way light & Input Voltage: Typically 160V-280V AC, suitable for standard household voltage. Light Source: SMD LED or Epistar LED chips.Color Temperature: 3000K (Warm White) is standard for cozy, non-glare illumination.Luminous IP Rating (Waterproofing): IP65, indicating dust-tight and protection against water jets (suitable for indoor/outdoor use).Material: Die-cast aluminum body (powder-coated, anti-corrosion) with a polycarbonate diffuser. Lifespan: Often up to 50,000 burning hours all as specified and directed |
| 50 | M&L for cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed. |
| 51 | M&L in replacement of earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately. |
| 52 | Deduct Schedule of credit (calculation will be done off line) Rs. 2750.00 Please Enable Macros to View BoQ information |