| 1 | Providing and fixing aluminium composite panel cladding of approved colour and shade, minimum 4 mm thick, comprising of two aluminium sheets each of minimum 0.5 mm thickness bonded to a non-toxic polyethylene / FR core, conforming to relevant IS standards, fixed on aluminium framework made of extruded aluminium sections of approved size, duly fixed to RCC / brick masonry with approved anchor fasteners. Panels shall be machine cut, grooved, bent and fixed using aluminium cleats / SS screws / rivets as approved. Joints shall be uniform and sealed with approved silicone sealant. The work includes all necessary framework, fittings, fixtures, sealants, scaffolding, cutting, bending, wastage, labour and tools, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided. |
| 3 | M&L for cement concrete in foundations, filling and mass concrete in type D2 1:4:8 (40mm graded aggregate) all as speciefied and directed. |
| 4 | Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar. |
| 5 | M & L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 6 | Taking down cement plaster on brick/concrete surface including racking out joints hacking for key scrubbing down with water etc. |
| 7 | Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc, |
| 8 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 |
| 9 | M&L Rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC as per manufacturers instructiion for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately). |
| 10 | M&L Rendering 5 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:3 for finished even and smooth (without using extra cement) |
| 11 | M & L for preparing new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resitant primer all as specified and as directed. |
| 12 | M& L for preparing and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 13 | M & L for Complete removal of exiting treatment by sanding/grinding and washing from wall and preparation of old surfaces of wall and applying two coats of oil bound distemper over and including a coat of 2mm average thickness birla/ equivalent wall care putty and one coat of alkali resitant primer all as specified and as directed. |
| 14 | M& L for Complete removal of exiting treatment from wall and preparation of old surfaces and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 15 | Supply only Internal water proofing compound (Liquid type) all as specified and directed (Dr Fixit Pidiffin/Sika or equivalent). |
| 16 | M&L for Granite (of any type) tiles 18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15 mm thick screed bed with CM 1:4 including necessary adhesive complete all as specified. |
| 17 | M&L for Granite (of any type) tiles 18- 20mm thick machine cut,in skirting/ dado laid over cement screed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15 mm thick screed bed with CM 1:4 including necessary adhesive complete all as specified. |
| 18 | M&L for Granite 18 to 20mm thick colour as approved by Engr-in-Charge (table rubbed and polished) for wall lining veneering to wall; 12mm thick in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 19 | Excavation in trenches nexc 1.5 mtr in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.Note: (i) During the excavation damage of Road, Electric cable,Signal cable and Sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface. |
| 20 | Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. |
| 21 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point. |
| 22 | M & L for sand cushioning for under ground cable with locally available clean sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed. (Note-Punned thickness ie 18 cm will be measured and paid) |
| 23 | M & L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise all as directed |
| 24 | Supply, laying, commissioning and testing in repairs of XLPE insulated, screened, PVC bedded, galvanised steel wire armoured heavy duty electric power cable with aluminium conductor, suitable for 1100 volts grade, in trenches , ducts,pipe on wall and poles complete all as specified and directed by Engineer- in -charge of following sizes :- |
| 25 | 16 sq mm 4 core |
| 26 | 10 sq mm 2 core |
| 27 | Supply & Fix of 15 Watt LED based bollard light fitting with MS pipe housing with glare free PMMA diffuser, IP 65,H=100mm New generation energy saving and environmental friendly long life LED bolard light complete all as specified and directed. Note :- The warranty on light should be minnimum of 3 Years provided by contractor . |
| 28 | Supply and Fix of 12 watt LED New generation IP 66, inground burial light with die cast aluminium housing with toughened glass , energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. Note :- The warranty on light should be minnimum of 3 Years provided by the contractor . |
| 29 | Supply and fix of 7 mtr Designer MS pole designed for Ornamental street light ,mounting with four numbers anchor bolts on foundation including double arm bracket for double mounting of drop down luminaries with inbuilt junction box(oval shape window) at the base of pole provision available for loop in& loop out complete all as specified and directed. |
| 30 | Supply and fix of energy efficient LED light 45 Watt IP 65 pendent mounting Ornamental road light aluminium die cast suitable for high efficency assymetric secondary lense ,operating voltage range 140V to 270V ,Operating temperature -10degree C to 50degree C,open and short circuit protection,reverse polarity protection,High voltage cut off at 310±20V and surge protection of 5KV Internal complete all as specified and directed. |
| 31 | M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 32 | Supply and fix three phase PVC Jnction Box of Size 30 cm x 20 cm x 10.5 cm with hinged door inculding locked arrangment with Connector/Bus Bar including necessary clamping. Nuts, bolt etc complete Please Enable Macros to View BoQ information |