| 1 | Appendix -1 .Working Charges |
| 2 | 100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 3 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | 15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road |
| 5 | 100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil. |
| 6 | 100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock. |
| 7 | 100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals. |
| 8 | 100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete. |
| 9 | 100.14.7:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 400mm diameter Ductile Iron Class K-9 Pipes. |
| 10 | 100.35.7:Testing 400mm DI/CI pipeline with potable water to the required test pressure.400 mm diaObserved Data derived from item no.1026 of PHED DATA |
| 11 | 18.83.9:Labour for cutting C.I. pipe with steel saw.400 mm diameter C.I. pipe |
| 12 | 18.70.7:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:400 mm dia pipes |
| 13 | 100.37.11.5:Grinding cut and weld edges of 400mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 14 | 100.14.5:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 300mm diameter Ductile Iron Class K-9 Pipes. |
| 15 | 18.70.5:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe |
| 16 | 100.37.9.5:Grinding cut and weld edges of 300mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 17 | 18.83.7:Labour for cutting C.I. pipe with steel saw.300 mm diameter C.I. pipe |
| 18 | 100.35.5:Testing 300mm DI/CI pipeline with potable water to the required test pressure.300 mm diaObserved Data derived from item no.1023 of PHED DATA |
| 19 | 100.14.2:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 150mm diameter Ductile Iron Class K-9 Pipes. |
| 20 | 100.35.2: Testing 150mm DI/CI pipeline with potable water to the required test pressure150 mm diaObserved Data derived from item no.1018 of PHED DATA |
| 21 | 18.70.2:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:150 mm dia pipes |
| 22 | 100.37.6.5:Grinding cut and weld edges of 150mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 23 | 18.83.4:Labour for cutting C.I. pipe with steel saw.150 mm diameter C.I. pipe |
| 24 | 100.14.1:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 100mm diameter Ductile Iron Class K-9 Pipes. |
| 25 | 100.35.1:Testing 100mm DI/CI pipeline with potable water to the required test pressure100 mm dia |
| 26 | 18.30.2:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:100 mm diameter pipe |
| 27 | 18.70.1:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:100 mm dia pipes |
| 28 | 100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes. |
| 29 | 100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I. |
| 30 | 100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I. |
| 31 | 100.31.1.9:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 400mm diameter, Class I. |
| 32 | OD49694/2023-2024:Alteration of 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE pipe up to 200mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching andrefilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe,, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding the cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of Engineer in charge |
| 33 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 34 | Appendix -2. Construction of Valve Chambers |
| 35 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 36 | 4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 gradedstone aggregate 40 mm nominal size derived from natural sources) |
| 37 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 38 | 5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 39 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 40 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 41 | 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster |
| 42 | Appendix-3.Cost of Materials |
| 43 | 100.98.121:Supply of DI K9 Pipe Conforming to IS 8329/2000, 400mm Dia. |
| 44 | 100.98.119:Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia. |
| 45 | 100.98.116:Supply of DI K9 Pipe Conforming to IS 8329/2000, 150mm Dia. |
| 46 | 100.98.115:Supply of DI K9 Pipe Conforming to IS 8329/2000, 100mm Dia. |
| 47 | 100.98.239:Supply of PVC Pipe, 10kg/cm2, 160mm Dia. |
| 48 | OD49695/2023-2024:Cost of PVC specials (Bends,Tee,coupler, Tailpiece,end caps,CID/CIR etc )3% cost of pipe. |
| 49 | OD49696/2023-2024:Supplying and fixing C.I man hole cover with frame for manholes:560 mm diameter ( heavy duty) the weight to be not less than 208 kg. |
| 50 | 18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia |
| 51 | 100.98.454:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 80mm. |
| 52 | 100.98.484:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm. |
| 53 | 100.98.489:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 400mm. |
| 54 | 100.98.494:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.0, Size 100mm. |
| 55 | Appendix -4. Interconnection Works |
| 56 | OD178865/2023-2024:Interconnection with both ends 400/350 DI of main line with suitable mechanical joint including fabrication charges, cost of specials , labour charges etc complete as per the direction of departmental officers |
| 57 | OD178864/2023-2024:Interconnection with both ends 150/100 DI of main line with suitable mechanical joint including fabrication charges, cost of specials , labour charges etc complete as per the direction of departmental officers |
| 58 | OD178863/2023-2024:Inter connection works in 400/350mm DI pumping main to existing DI/PVC distribution lines including earth work excavation in ordinary soil exposing the pipe in cutting the existing line and inserting tee and fixing reducer with help of solvent cements and necessary protection work and bailing out water back filling the trenches and controlling the valve including cost of specials, labour charges etc. complete as per the direction of departmental officer. |
| 59 | OD178862/2023-2024:Inter connection works in 150/100mm DI pumping main to existing PVC distribution lines including earth work excavation in ordinary soil exposing the pipe in cutting the existing line and inserting tee and fixing reducer with help of solvent cements and necessary protection work and bailing out water back filling the trenches and controlling the valve including cost of specials, labour charges etc. complete as per the direction of departmental officer. |
| 60 | OD178861/2023-2024:Inter connection works in 160 mm PVC pumping main to existing PVC distribution lines including earth work excavation in ordinary soil exposing the pipe in cutting the existing line fixing using specials with help of solvent cements and necessary protection work and bailing out water back filling the trenches and controlling the valve including cost of specials, labour charges etc. complete as per the direction of departmental officer. Please Enable Macros to View BoQ information |