| 1 | SUB-HEAD 1--DISTRIBUTION WIRING. |
| 2 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment.Average run 8 Mtr. [ 1(c) / E-24] |
| 3 | On Board. [3(a/E-24] |
| 4 | SUB-HEAD 2--CUTTING CHANEL & WIRE LAYING. |
| 5 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works |
| 6 | 20 mm size |
| 7 | Cutting Channel of following size on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks as per GS. |
| 8 | 20 mm dia 3 mm thick |
| 9 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 10 | 2x(1.5 sqmm)+1x(1.5 sqmm) |
| 11 | 2x(2.5 sqmm)+1x(1.5 sqmm) |
| 12 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 13 | 1.5 sq.mm |
| 14 | 2.5 sq.mm |
| 15 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 16 | 200 mm x 150 mm x 65 mm |
| 17 | 240 mm x 200 mm x 65 mm |
| 18 | Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws |
| 19 | 200 mm x 150 mm x 65 mm |
| 20 | 240 mm x 200 mm x 65 mm |
| 21 | SUB-HEAD 3--PLUGS & SWITCH. |
| 22 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated with two pole 32A MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 2 Way [11/D-9] & [7/D-6] |
| 23 | Supply & Fixing 240 V, 16 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [17(b)/E-6] |
| 24 | SUB-HEAD 4--FIXING OF LIGHT FITTINGS. |
| 25 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. [14(a)/C-2] |
| 26 | Fixing only lamp . [11/C-2] |
| 27 | Fixing only recess mounted LED ceiling fitting on wall /ceiling by screws etc . |
| 28 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. [13/C-2] |
| 29 | SUB-HEAD 5--SUPPLY OF LIGHT FITTINGS. |
| 30 | S & D 20W LED Lamp with Holder ( Orient , PHILIPS, Magik). (3 yrs on site warranty) (Garden) |
| 31 | S & D 12 W LED Lamp ( PHILIPS, Magik, Orient). (3 yrs on site warranty) |
| 32 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/WattSingle fittings along with S/F of 1 no. 18-20 W LED lamp as per specification |
| 33 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted.(System lumen efficacy ≥115 lm/WattTwin fittings along with S/F of 2 no. 18-20 W LED lamps as perspecification |
| 34 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy ≥ 110 lm/Watt. System lumen efficacy shall be as below: |
| 35 | Cat No.-Philips- duraslim 22W-CDL/Similar Model |
| 36 | Cat No.-Philips-duraslim 18W-CDL/Similar Model |
| 37 | Cat No.-Philips-duraslim 12W-CDL/Similar Model (Room) |
| 38 | Cat No.-Philips Slim Surface Mount+ 12W-CDL/Similar Model |
| 39 | Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) COB with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, Operating temp range 00 to 400 C, internal surgeprotection of 2.5 KV with Short & Open circuit protection, THD <10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electricalcircuitary), of minimum 50000 Burning Hours (Life projection shallbe calculated as per TM-21 methodology) and 70% of initial Lumenmaintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K, Maximum power consumption should not more than thespecified rating and Fixture shall be confirming to relevant BISstandards and trade mark certificate (T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housingComplete in all respect and LED Chips of SMD Low to mid-power, asper requirement (LM-80 tested) and necessary inter-connections with1.5 sq mm FR, PVC insulated copper conductor single core cable andearthing etc. as required with Minimum 5 year OEM comprehensiveon-site warranty against manufacturing defects including driver andLED module. All test report except L80 should be from 3rd partyNABL accredited Lab as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement---System lumen efficacy ≥ 110 lm/Watt |
| 40 | Cat No.-Philips COB pro-3W-CDL/Similar Model (Room) |
| 41 | Cat No.-Philips COB pro-7W-CDL/Similar Model |
| 42 | Supplying, installation, Testing & Commissioning of 25 watt LED Strip (Length of 5 mtr) of Uncoated Synthetic material and Superior adhesive for easy installation and no. of LED 144 LED/mtr, system lumen efficiency 600 lm/mtr as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and Driver efficiency >80%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range 0 degree to 40 degree C internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.9, IP20, CRI >80, life time (LED,Driver & electrical circuitry), of minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends as per LM80 report, CCT 3000°K / 4000°K /6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, complete in all respect and LED Chips of SMD Low to mid-power, as per required (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Color WW/NW/CDL (Length of 5 mtr. (Make -Philips/Havells/Wipro).Cat No.- Cove Glow/Similar model |
| 43 | Supply of Elegant looking, superior finish, easy to maintaining Wall mounting 12 watt LED light fitting for indoor application, complete with all accessories having following Model / Cat No. (Make -Philips/Havells/Wipro) {05 yrs on site warranty}. Cat No.- Sense of Style 30978/Similar model |
| 44 | Supply of wall mounted LED Bulk head light (with IP66)Minimum Lumen Out of Luminaries:- 100 lm/watt), complete with all accessories having following Model/Cat No. [Make- Philips/Crompton/Orient/As per choice of EIC]. Model/Cat No.- WT202W LED6S NW PSU S2 PC /Similar Model. (5 yrs on site warranty) |
| 45 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.System lumen efficacy 135 lm/watt |
| 46 | (Cat no:- Magik SPBL045C/Similar Model) RING light |
| 47 | (Cat no:- Magik SPBL060C/Similar Model) Roof light |
| 48 | (Cat no:- Magik SPBL075C/Similar Model) Pole light |
| 49 | S & D IP65 protection, efficiency >110 lm/Watt glare free LED out door Post Top luminaire. [Make:- Magik/Orient/Surya / As per Coice of EIC.] (Cat no:- APBY040C /Similar Model) |
| 50 | SUB-HEAD 6--FIXING OF FANS. |
| 51 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS. [10)/E-18] |
| 52 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS. [21(a)/C-3] |
| 53 | Fixing only 9\\" exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter. [28(a)/C-4] |
| 54 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long). 12\\" [33/D-14] |
| 55 | SUB-HEAD 7--SUPPLY OF FANS. |
| 56 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm)Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.(Make - USHA Striker Galaxy/Crompton/Orient). {02 yrs on site warranty} |
| 57 | SUB-HEAD 8 -CABLE, LAYING, GLAND & SOCKET |
| 58 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size2 core 6 sqmm Armoured |
| 59 | Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. [7(a)/F-4] & [8(b)/F-5] 2 core 6 sqmm |
| 60 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. [2(a)/F-1] |
| 61 | Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 62 | Supplying & fixing medium gauge 40mm GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. |
| 63 | SUB-HEAD 9--Erection of Pole & Accessories. |
| 64 | Supply & Delivery of 7 Mtr Steel Tubular Pole (steel mk Zindal/Bansal) pole manufacturer (Transrail/Calcutta poles/Subham) as per specification as overall length 7.0 mtr, including base plate welded at bottom, pole cap, & having diamention are : Out side dia & thickness of the Bottom section ( 114.3x5.4) mm,length- 4000mm, Mid section ( 88.9 x 4.8) mm, length- 1500 mm, Top Section (76.1 x 3.25 ) mm , length - 1500 mm, 410 SP - 3 (75KG) with 40 mm dia 1.5 mtr Double Arm bracket & Nut Bolts as per direction of EIC. |
| 65 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts.above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly as per GS.Upto 9.0 mtr. Size 0.6x0.6x1.70 mts [1(a)/H-1] |
| 66 | Painting the steel tubular pole of lengths and no. of coats of paint as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.( 4(a)/H-2) |
| 67 | i) 1st coat of aluminium paint over 1 coat of RO priming. |
| 68 | ii) 2nd coat of aluminium paint over 1st coat. |
| 69 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [5/H-5] |
| 70 | Wiring with 3X1.5 Sqmm PVC copper wire in 13mm dia polythene pipe from loop box to LED fitting. |
| 71 | Supply & Fixing 1.5 inch PVC heavy Suction Hose pipe from foundation to loop box. |
| 72 | Supply & Fixing of 25 mm dia GI pole cap 1.0 mtr Double Arm bracket & Nut Bolts as per direction of EIC |
| 73 | SUB-HEAD 10--SIGN BOARD. |
| 74 | Supply & Fixing of LED Tube illuminated sign board fabricated by 14ft(L)x5ft(H)x10inch(W) ACP box supported with M.S. Angle structure all around with 40mm x40mmx 6 mm Al. edge angle.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (20 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated painting iron structure as per direction of EIC |
| 75 | Fabrication charge of the M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section) incl. painting. including Supplying of Supply of MS Channel (150x75x6mm), M.S. angle (50 x 50 x 5 mm), MS base plate (8mmx450mmx450mm) etc supporting of sign board with nut & bolt on both sides, mounting on having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc e supporting of glow sign board etc include carrying charges as per direction of EIC |
| 76 | SUB-HEAD 11--EARTHING. |
| 77 | Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil. [1(a)/G-1] |
| 78 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) do----do---as per GS. By ISI-Medium GI pipe. [2(a)/G-1] |
| 79 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 6 SWG GI Wire. [5a(ii)/G-2] |
| 80 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. [4(a)/G-2] |
| 81 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2] |
| 82 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode. [3(b)/G-2] |
| 83 | SUB-HEAD 12--MISCELENEOUS. |
| 84 | Dismantling main switch, switch board, existing wiring & unservisable materials incl. Mending good the damaged of building works and submit those materials to the concerned authority by one electrician, one no masson, 1 nos helper as per instruction of EIC. |
| 85 | Dismantling 1.5 T Split AC machine with pipe, wire, cable & indoor-outdoor uni incl. Mending good the damaged of building works and re-installing the same at same place of the room by one AC Technician & one nos helper as per instruction of EIC. Please Enable Macros to View BoQ information |