| 1 | 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood |
| 2 | Provinding and Fixing 15 mm thick densified tegular edged eco frendly ligh weight calcium silicate false ceilling tiles of approved texture of size 595x595 mm in ture horizontal level, suspended on inter loacking metal grid of hot dipped galvanised steel section ( galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitable spaced at joints to get required length and of size 24x38 mm made from 0.33 mm. thick (minimum) sheet, spaced 1200 mm. centre to centre and cross 'T' of size 24x28 mm. made out of 0.33 mm (minimum) sheets 1200 mm long spaced between main 'T' and 600 mm. centre to centre form a grid of 1200x600 mm. and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600 mm. resting on periphery walls/ partitions on a Perimeter wall angle pre-coated steel of size (24x24x2300 mm make of 0.40 mm thick (minimum sheet with the help of rawl plugs at 40 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including cutting/making opening for serivces like diffusers, grills light fitting fixtures smoke detectors etc, wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm. G.I. adjustable rods with galvanised sheet level clips of size 85x30x0.8 mm. spaced at 1299 mm centre to centre along main 'T' bottom exposed with 24 mm. of all tsections shall be pre-painted with polyster baked paint for all heights as per specifications. drawing and as directed by Eng. in charge |
| 3 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). |
| 4 | Providing & fixing 12 mm thick Toughen Glass Complete with Labour & materials in opeaning of railing and window etc. |
| 5 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect CAT- AAA |
| 6 | Wiring point for light with 1.5 sqmm FR PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe conceled in the wall, complete with 14 SWG copper earth continuty wire, piano type switch & ceiling rose/angle/batten holder on 3 mm thick Phenoplic lamoinated back light sheet etc. complete in all respect, as directed including matching colour wash.As per above but PVC conduit with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 7 | S& F 32 Amp 415 Volt metal clad HRC type switch fuse unit complte with on angle iron bracket complete in all respect. |
| 8 | S& F 63 Amp 415 Volt metal clad HRC type switch fuse unit complte with on angle iron bracket complete in all respect. |
| 9 | Supply & wiring of sub main with two no.- 4 sqmm FR PVC insulated 1100 volt grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit on surface, with one number 14 SWG copper earth continuty wire. complete in all resoect. As per above but in in 20 mm dia heavy duty ( 2 mm thick) PVC conduit with one number 2.5 sq.mm multistrand copper conductor cable as earth continuity wire drawn in conduit. |
| 10 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete:On Steel Work |
| 11 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building foroccupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete,as per the Architectural drawings, as per item description, as specified, as perthe approved shop drawings and as directed by the Engineer-in-Charge. However,for the purpose of payment, only the actual area on the external face of the curtainwall with Aluminum Composite Panel Cladding (including width of groove) shallbe measured in sqm. up to two decimal places. |
| 12 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 13 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
| 14 | Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvaturefor easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment). Please Enable Macros to View BoQ information |