Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Boundary Wall:- Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 2 | Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype |
| 3 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 4 | Reinforced cement cocrete M-20 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth. |
| 5 | Shuttering for faces of concrete foundations and foundationbeam and plinth beam |
| 6 | Reinforced cement cocrete M-20 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steel reinforcement, centering and shuttering in super strucutre |
| 7 | Centering and Shuttering for Column faces ( Square or Rectangular or polygonal in plain) |
| 8 | Centering and Shuttering for sides and soffits of beams, beams launching girders bressumers, lintels |
| 9 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete CSR 18.18 |
| 10 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 11 | 20 mm thick cement plaster 1:5 |
| 12 | 12.5 mm thick cement plaster 1:5 |
| 13 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 14 | Iron grated doors, including pintle hinges & arrangements. |
| 15 | Preparation of plastered or concrete surface for painting including sand papering the surface using readymixed cement based wall putty by applying two coats to get reqiered finish complete. |
| 16 | Finishing Wall With Acrylic Smooth Exterior Paint With two or more coats applied @ 1.67 l/sqm over and including base coat of water proofing cement paint applied @ 2.20kg/10sqm |
| 17 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.(CSR 16.21 b) |
| 18 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 19 | Volly Ball Court:- Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 20 | Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type |
| 21 | CC 1:2:4 with stone ballast |
| 22 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 23 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 24 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 25 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 26 | Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge |
| 27 | Providing & fixing Volley ball poll pairs made of MS standard size complete in all respects |
| 28 | Providing & fixing Volley ball net of polyster white colour size 9.5m x 1.00 m, mesh size 100mm x 100mm complete in all respects |
| 29 | Basket Ball:- Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 30 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling using mechnical mixture for mixing of material. |
| 31 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 32 | Providing & fixing of movable and height adjustbale.Basketball poll pairs made of MS standard size complete in all respects |
| 33 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 34 | Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type |
| 35 | CC 1:2:4 with stone ballast |
| 36 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 37 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 38 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 39 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 40 | Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge |
| 41 | Teniss Court:- Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 42 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling using mechnical mixture for mixing of material. |
| 43 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 44 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 45 | Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype |
| 46 | CC 1:2:4 with stone ballast |
| 47 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 48 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 49 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 50 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 51 | Providing and laying multilayer synthetic acrylic flooring (8 layers) approved by ITF on already laid flooring system complete in all respects and as per specifications laid in handbook on field of play published by SAI |
| 52 | Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge |
| 53 | Providing & fixing Tennis net with pair of polls complete in all respects |
| 54 | Badminton:- Compaction of earth work & Preparation of sub grade including loosening, leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 300-2 as per Technical clause 305 of MORT&H specifications. (In case of link roads earth work to be done by villagers) |
| 55 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling using mechnical mixture for mixing of material. |
| 56 | Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype |
| 57 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 58 | Providing & fixing Badminton Pole pairs made of MS and polyester net (movable) standard size complete in all respects |
| 59 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 60 | Cement Concrete 1:8:16 with 40mm guage Stone Ballast Using Concrete Mixture Volumetrictype |
| 61 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 62 | 400 Mtr. Track:- Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 63 | Cement concrete 1:8:16 with 40 mm gauge stone ballastusing computerized concrete batch mixing plant including carriage by transit mixer with in 1km lead . |
| 64 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 65 | Compaction of earth work & Preparation o sub-grade including loosening, leveling of earth 225mm thick top layer,rough dressingof soil,final dressing of earth to give level,camber,watering, rolling with road roller,compacting the bed to achieve minimum dry density as given in Table 300-2 as per technical clause 305 of MORT&H specifications |
| 66 | Providing and Laying sand filling laying in 15 cm layers, ramming, watering and consolidating including all leads. |
| 67 | Providing and Laying Brick bats in 115 mm layers grouted with sand, including all leads Complete as per Specifications and to the entire specification of engineer-in-charge |
| 68 | Lime Concrete (1:2:8) (0.13 cum lime, 0.26 cum surkhi one cum brick blast) 40mm Gauge |
| 69 | Providing & laying Coal cinder mixed with earth in (70:30) ratio in 10cm layers ramming, watering, & Consolidating with road roller including all leads complete in all respect as per specification and as desired by Engineer in charge. |
| 70 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surfaces |
| 71 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade |
| 72 | Football Ground:- Fine grassing including uprooting rank vegetation and weeds by digging the area to a depth of 30 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed. a( Planting Selection no. 1 grass roots in rows 5 cm apart in both directions as per csr 32.9 a |
| 73 | Maintenance of fine grass lawn for one year including fertilizer application, watering, weeding, top dressing with good earth and manure mixture, maintaining fine level, regular mowing and removal of rubbish with all lifts and leads. as per csr 32.10 |
| 74 | P/F Football Pole made of MS Standerd size and black color polyester net complete in all respects |
| 75 | ELECTRICAL PANEL ROOM CUM CHONKIDAR:- Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 76 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage.mixing by mechanical means using concretemixer volumetric type |
| 77 | First Class B.B. Work Laid in Cement sand mortar in 1:6 in foundation and plinth |
| 78 | Reinforced cement concrete M-20 mechanical batch mixed using batch type concrete mixer as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering in foundation and plinth. |
| 79 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 80 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 81 | 115mm thick brick wall in cement sand mortar 1:4 without reinforcement in superstructure |
| 82 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 83 | Cold twisted deformed (ribbed/tor steel) Bars Fe 500 grade as per IS 1786-1985, for RCC works etc. |
| 84 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 85 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landing, chajjas, shelves etc. |
| 86 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 87 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 88 | Wrought iron & Mild steel ladders, framed grills,gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 89 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flashwelded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items) |
| 90 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 91 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated lead upto 1000 metres |
| 92 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 93 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 94 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5cm cement concret 1:8:16 including 12.5mm thickcement plaster 1:3 |
| 95 | Providing and fixing on walls face unplasticised rigid PVC rain water pipes single socketed (working pressure 4 Kgf/cm2 ) confirming to IS : 4985 including fixing with MS clamps U-PVC pipes (working pressure 4 kgf/cm2) pipes 100 mm dia |
| 96 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 97 | 12.5mm thick cement plaster 1:4 |
| 98 | 20mm thick cement plaster 1:4 in two coat work |
| 99 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 100 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Design is homogenous throughout the tile body ). |
| 101 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 102 | Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects |
| 103 | Supply & fixing glass panes with glazing clips and special metal sash putty etc. (4mm thick above 0.40 Sqm. area) |
| 104 | Preparation of plastered or concrete surface for painting including sand papering the surface using readymixed cement based wall putty by applying two coats to get reqiered finish complete. |
| 105 | Wall painting with plastic emulsion paint fo approved brand and manufacturer to give an given shade (two coats) |
| 106 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 107 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 108 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 109 | Pavilion:- Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 110 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 111 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 112 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 113 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 114 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. |
| 115 | Extra rate for First Floor |
| 116 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 117 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 118 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 119 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 120 | Centring and shuttering for parapet, fascias and other similar items including edges |
| 121 | Providing and fixing on walls face unplasticised rigid PVC rain water pipes single socketed (working pressure 4 Kgf/cm2 ) confirming to IS : 4985 including fixing with MS clamps U-PVC pipes (working pressure 4 kgf/cm2) pipes 100 mm dia |
| 122 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 123 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 124 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 125 | Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating |
| 126 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 127 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. |
| 128 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 129 | Construction of embankment with good quality earth obtained from borrow pit including compensasion of earth, bading deenage to sine of work spreading, grading to required slope and compacting to meet requirement table 300-2 as per technical clause 305 of MORT&H specificatioms |
| 130 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
| 131 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) |
| 132 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 133 | 12.5mm thick cement plaster 1:5. |
| 134 | 20 mm thick cement plaster 1:5 in two coats work. |
| 135 | 12.5 mm thick cement plaster 1:4. |
| 136 | 20mm thick cement plaster 1:4 in two coat work. |
| 137 | Kota stone tile flooring 20mm to 25 mm thick over 20mm thick base of cement mortar 1:4 (1 cement, 4 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing. |
| 138 | Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing |
| 139 | Providing and fixing Morwad marble strip 18mm to 20mm thick and 100mm wide in Kotah Stone Flooring over 12.50 mm thick base of cement mortar 1:3 jointed with cement slurry including cost of aditional mortar equivallent to the kotah stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. |
| 140 | Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 141 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 142 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects. |
| 143 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area.Glass panes 4mm thick, exceeding 0.40 sqm. area. |
| 144 | Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.70 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect. |
| 145 | Providing & fixing teak wood top size 150mm x 75mm on stair railing including polishing complete in all respect. |
| 146 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS- 2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick |
| 147 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutterarea above 0.50 sqm |
| 148 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 149 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :For fixed portion & Chaukhat |
| 150 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 151 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .. |
| 152 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)With float glass panes of 5.5 mm thickness. |
| 153 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge. |
| 154 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 155 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 156 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 157 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) |
| 158 | Applying priming coat with metal primer on new steel or iron work including preparation of surface.With ordinary quality Paint |
| 159 | Painting two coats excluding priming coat with synthetic enamel paint inall shades on wood work, metallic or plastered, concrete surface to give an even shade with ordinary quality paint. |
| 160 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 161 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 162 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give aneven shade with ordinary quality paint. |
| 163 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 164 | PARKING AND APPROACH ROAD:- Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications as per CSR 24.5(a) |
| 165 | Clearing jungle manually including uprooting rank vegetation, grass, woody vegetation up to 30 cm girth measured at height of 1 m above ground level and removal of rubbish up to distance of 50 m outside the periphery of the area cleared |
| 166 | Compaction of earth work & Preparation o sub-grade including loosening, leveling of earth 225mm thick top layer,rough dressingof soil,final dressing of earth to give level,camber,watering, rolling with road roller,compacting the bed to achieve minimum dry density as given in Table 300-2 as per technical clause 305 of MORT&H specifications |
| 167 | Construction of granular sub-base by providing coarse graded material grading-II, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications |
| 168 | Providing, Laying & Compacting of Grading - II ( 63 - 45 mm gauge stone metal ) to W.B.M. Specifications without Screening |
| 169 | Providing, Laying & Compacting of Grading - III ( 53 - 22.4 mm gauge stone metal ) to W.B.M. Specifications without Screening |
| 170 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths). |
| 171 | Precast Cement Concrete KerbsProviding and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 172 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint |
| 173 | Gym:- Abs Exercise Double 4\\" round pipe heavy. |
| 174 | Leg Shaper or Press (double) 4\\" round Pipe heavy. |
| 175 | Shoulder Shaper or Press (double) 4\\" round Pipe heavy. |
| 176 | Air Walker 3\\" round Pipe heavy. |
| 177 | Triple twister 4 \\" round Pipe heavy. |
| 178 | Single Skier 4\\" round Pipe heavy. |
| 179 | Shoulder Wheel 4-ways 4\\" round Pipe heavy. |
| 180 | Electrical Work:- RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 181 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 182 | Wiring fan point (With fan box) |
| 183 | Wiring light point |
| 184 | Wiring 6Amp. wall socket point |
| 185 | Wiring 6Amp. Plug control comprising wall socket point |
| 186 | Wiring 16/20Amp. power plug control point |
| 187 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 188 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 189 | Overall size 1.5sq.mm (Un-sheathed) |
| 190 | Overall size 4sq.mm (Un-sheathed) |
| 191 | Overall size 6sq.mm (Un-sheathed) |
| 192 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 193 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 194 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 195 | MINIATURE CIRCUIT BREAKERS: |
| 196 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 197 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 198 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 199 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 200 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 201 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in thedistribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 202 | SP&N Double Door Distribution Board 4 way each |
| 203 | SP&N Double Door Distribution Board 8 way each |
| 204 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 205 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 206 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 207 | Overall size 25sq.mm (3½ Core) Un-armoured (Loose) |
| 208 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 209 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 210 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 211 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 212 | Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) |
| 213 | G.I. EARTHING: |
| 214 | Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 215 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 216 | G.I. EARTHING WIRE/ ROPE (AS ADDITIONAL LENGTH): |
| 217 | Fixing additional length of earthing with G.I. wire/ rope in G.I. pipe (Flushed in wall and floor) with sockets, elbows and Steel hooks including the cost of cutting and filling up of chases (with finishing the surface):- |
| 218 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (Flushed) |
| 219 | COPPER EARTHING (Upto 14 metre in Length): |
| 220 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 221 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 222 | COPPER EARTHING STRIP (As Additional Length): |
| 223 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 224 | Additional Length 20mm x 3mm thick Copper Tape |
| 225 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): |
| 226 | LT PANELS: |
| 227 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. |
| 228 | The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. |
| 229 | The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. |
| 230 | Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. |
| 231 | Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- |
| 232 | LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) |
| 233 | MCCB's (FOR PANELS & SHEET ENCLOSURE): |
| 234 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 235 | MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting (Outgoing) |
| 236 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting (Incomer) |
| 237 | Supply and erection of LED batten 20 Watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture more than 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. |
| 238 | Supply and erection of LED batten 40watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture operating voltage between 140 to 270 volt complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. |
| 239 | Supply and erection of Ceiling Fans 1200 mm Sweep (48\\") having two ball bearing including flexible wire & petty material etc.complete in all respects as appd. and desired by the Engineer in-charge at site. |
| 240 | Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with Louver shutter (Make:Canon or equivalent) of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 241 | Supply and erection of Heavy duty Exhust Fans 380mm 900RPM complete with aluminium Louver shutter (Make:Canon or equivalent) of double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 242 | Supply and erection of High efficiency round highbay 80 Watt Surface mounted Weather proof corrosion resistant, pressure die-cast aluminium housing with high power LED as light source IP 65/66 ratings for industrial and other applications in exposed climates requiring higher degree of ingress protection more than 120 lumens per watt and operating voltage between 140 to 270 volt complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. |
| 243 | GI PIPE POLES & BRACKETS :- |
| 244 | GI PIPE POLES: |
| 245 | Supply and erection of G.I. pipe ‘A’ quality of suitable length and dia. confirming to IS:1239 (Part-I) 1979, including fixing up to a given depth below G/L, the hole of excavation about 30cm dia. and given depth to be filled in up to 15cm below G/L with 1:2:4 cement concrete including painting of pole with two coats of approved aluminium paint as required:- |
| 246 | II) G.I. Pipe Pole 6.1 metre Long, Dia. 80mm, Planting Depth 120cm with Pit Depth 135cm. |
| 247 | SINGLE ARM BRACKETS FOR GI PIPE POLE: |
| 248 | Supply and erection of G.I. Pipe 40mm dia. (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:- |
| 249 | Single Arm Bracket 1 metre Long with G.I. Reducer 80mm x 40mm |
| 250 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-I) ICDP Switch 32amp., 415volts |
| 251 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- A) GI Earth rod 20 mm dia., 3 mtr. Long |
| 252 | PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: |
| 253 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 254 | Overall size 1.0sq.mm (32/0.20mm), 3Core |
| 255 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 256 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 257 | Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 258 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 259 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 260 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 261 | CEMENT CONCRETE MUFFS: |
| 262 | Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's). The SMC Junction Box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 263 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long with making an extra collar (If pole installed in Centre verge/ Footpath) will be provided with 1:2:4 cement Sand & concrete mixture around the Steel tubular pole. The size of collar (height is 40cm & dia. is 45cm including pole dia i.e. 168.3mm) |
| 264 | Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear (with IP 65/ IP 66 protection),THD< 10%, CRI>70, High power LED with mandatory modular lenses, toughened glass fitting, surge protection 10KV and efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. |
| 265 | S/I/T/C of 16 Mtr High Mast Lighting with Latching Arrangements System as per IS : 875 :1987 (Part-III) manufactured on CNC Automated , Automatic plasma cutting machine mechanism for steel cutting, automatic saw welding with same strenght Arc as steel for welding, countiuouns polygonal structure as per wind speed of 180 km per hour tested from IIT with wind tunnel testing , single hot dip galvanizing for maintenance life of Minumum 25 years with all the otehr exposed parts, High tesile sheet steal confirming to BSEN- 10025 with tensile strength 355N/Sqm with special latching Arrangment head frame galvanized lantern carriage etc as per below mentioned specifications, Mast shaft shall be in two sections as per IS 875, Lighting finial excluding foundation bolts manufactured from special steel along with nuts washers, anchor plate , templates and LED type single dome aviation obstruction light . The mast shall have an integral power tool installed inside the base compartment for its operation. Luminare wiring materials not included in the mast supply pricesand as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. ATPB/04/PMB Dated 04 Sep 18 and Letter No:-ATPB/69/GL Dated:- 03 OCT 18. Bajaj, Valmont, Transrail (Specifications as per approved estimate) |
| 266 | Making Reniforced Cement Concrete Foundation of size 850mmX850mmX1800mm for 16 Mtr. High Past Pole including Earth work in excavation 1900mmX2700mmX2700mm=13.851cum, Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) complete 4X2700mmX100mm = 1.08 sqm,Providing/Laying of cement concrete 1:4:8 with brick/stone complete 2700mmX2700mmX100mm = 0.729 cum, Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Complete 4X2500mmX300mm = 3 sqm, Providing/Laying reniforced cement concrete M25 (2500mmX2500mmX300mm) = 1.875 cum, Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. Complete 4X850mmX1800mm = 6.12 sqm, Providing/ Laying reniforced cement concrete M25 (850mmX850mmX1800mm) =1.30 cum, Providing/ Laying of cold twisted deformed bar FE-500 4mmX10mmX2700mm (10 mm dia)+12mmX2100mm (12mm dia)+10mmX3200mm (6mm dia)+2mmX10mmX2000mm (6mm dia) = 1.05 Qtl. Complete in all respect as per drawing supplied by the pole manufacturer. |
| 267 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-a) Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 268 | Supply and erection of LED Flood Light 300watt (including LED driver) with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection),THD< 10%, CRI Minimum 70, High power LED with mandatory modular lenses, toughened glass fitting, surge protection 10KV and efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 269 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-ii) MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 270 | xi) MCB Triple Pole 40amp. (10kA, Curve-C) |
| 271 | xv) MCB Four Pole 40amp. (10kA, Curve-C) |
| 272 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-v) TP&N Horizontal Double Door Distribution Board 4 way each |
| 273 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 274 | Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 275 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (CCurve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-incharge:- Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (CCurve, 10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 276 | Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- Cubical Size 1200mm high, 1000mm wide and 500mm deep with platform dimensions 1100mm x 600mm x 450mm |
| 277 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 25sq.mm (3½ Core) Un-armoured (Loose) |
| 278 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.) |
| 279 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 6sq.mm (Un-sheathed) |
| 280 | Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 3Core |
| 281 | Public Health:- Cutting chase in brick walls in cement or in floorfor embedding G.I. or C.I pipes line and making good the same to its original condition.A) Size 75 mm x 75 mm |
| 282 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.B) Through wall 22.86 cm thick |
| 283 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. b) CPVC SDR 11 Pipe & fitting 20mm o/d |
| 284 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C anufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.B) Single Socket Type Bb) 110mm o/d SWR UPVC pipe line laid complete |
| 285 | c) 90mm o/d SWR UPVC pipe line laid complete |
| 286 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling using mechnical mixture for mixing of material. |
| 287 | Laying of Dry Brick Ballast 40mm Gauge for Flooring. |
| 288 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Soluble Salt Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Soluble salt Print Penetration should be up to 1 to 2 mm after the tiles are fired & polished ). Size 600x600 mm |
| 289 | 12.5mm thick Cement Plaster 1:4 |
| 290 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 291 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )110mm o/d SWR UPVC pipe lines laid |
| 292 | 90 mm o/d SWR UPVC pipe lines laid |
| 293 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipesDoor Cap |
| 294 | Single Tee |
| 295 | Elbow 90 Degree (All side socketed) |
| 296 | Vent Cowls |
| 297 | Coupler |
| 298 | P Trap/Floor Trap 110mm x 75mm |
| 299 | Nahani trap without jali 110mmx90mm |
| 300 | For 90mm o/d pipesDoor Cap |
| 301 | Single Tee |
| 302 | Elbow 90 Degree (All side socketed) |
| 303 | Vent Cowls |
| 304 | Coupler (Description Changed) |
| 305 | Making block for Floor Traps, P Traps, Junctions etc. using cement concrete 1 : 2 : 4 including labour and material charges complete in all respects. |
| 306 | Cement concrete 1:2:4 With stone ballast or shingle mixing by manual means |
| 307 | Extra Rate for Machine moulding of Granite Slab complete in all respect |
| 308 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 309 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 310 | Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (b) Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect. |
| 311 | Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-incharge) complete in all respect |
| 312 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. (a) With CP BrassNut |
| 313 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 550 mm x 400 mm x 815 mm |
| 314 | Size 560mm x 450mm (Under counter oval) |
| 315 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. (i) Vitreous chinaware standard white pedestal for wash hand basin |
| 316 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect |
| 317 | Providing and fixing C.P. brass Urinal Spreader Ocular-Regular complete with fittings for urinals complete. |
| 318 | Providing & Installing Battries for Senso Urinal Duracell make complete in all respects |
| 319 | Vitreous white Chinaware Partition (i) Small partitions size 69 x 16.5 x 32.5 cm |
| 320 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. (b) C.P.brass 15mm Concealed stop cock with flange. |
| 321 | (c) C.P.brass 15mm Angle valve without flange |
| 322 | Providing and fixing Stainless steel health faucet complete in all respect |
| 323 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. (a) C.P. brass toilet paper holder |
| 324 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. (a) C.P. brass towel Rails size 15mm dia 610mm long |
| 325 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 326 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect.C.P. brass Bib cock long nose/ long body foam flow without flange |
| 327 | C.P. brass Bib cock foam flow without flange |
| 328 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 329 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete inall respect. |
| 330 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 331 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 332 | Providing & Fixing CP Waste 32mm complete in all respect. |
| 333 | Providing & Fixing in position mirror of superior glass Size 1500mm x600mm or any other required size (of approved quality) and of required shape and size with high quality polystyrene moulding frame of 40 to 50mm size (of approved quality and shade) with 4mm thick hardboard backing fixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect |
| 334 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all respect. PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut |
| 335 | Providing and fixing in position S.S. Grating with frame of approved make (to the approval of Engineer-in-charge) complete in all respect (Previously item no.30.104) |
| 336 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer |
| 337 | Providing and fixing in position automatic brass Ball Cock in tanks. (b) (ii) Brass Ball Cock with rod and Plastic Ball 20mm i/d |
| 338 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d |
| 339 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.25mm i/d Gun Metal peet valve heavy pattern. |
| 340 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.25mm i/d |
| 341 | Construction of Plateform for placing PVE Water Storage Tank with brick Ballast work Plaster, CC 1:8:16 & 1:2:4 Cement Regarding etc of Size 1.07 x 1.07 x 0.23 m compeleted in all Respect |
| 342 | Construction of Plateform for placing PVE Water Storage Tank with brick Ballast work Plaster, CC 1:8:16 & 1:2:4 Cement Regarding etc of Size 1.20 x 1.20 x 0.23 m compeleted in all Respect |
| 343 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 344 | Providing and installing Automatic Voltage Stabilizer of 5 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect. |
| 345 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge) including carriage and fixing in position complete in allrespect. |
| 346 | Making RCC slab of size 6' x 2'-0\\" including cost of material, centering and shuttering, labour, chasing in wall and all other works contingent thereto. |
| 347 | Making RCC slab of size 8'6\\" x 2'-0\\" including cost of material, centering and shuttering, labour, chasing in wall and all other works contingent thereto. |
| 348 | Making RCC slab of size 22'9\\" x 2'-0\\" including cost of material, centering and shuttering, labour, chasing in wall and all other works contingent thereto. |
| 349 | Drilling hole in granite for provision of centre hole basin mixer complete in all respects. |
| 350 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete. |
| 351 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 |
| 352 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complet |
| 353 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 354 | Providing & Fixing Exhaust Fan of reputed make including cost of Labour & Material complete in all Respect |
| 355 | Providing & Fixing of Electric Tube Set of reputed make including cost of Labour & Material complete in all Respect |
| 356 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths asshown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric ines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m)complete in all respects.Depth not exceeding 3 m. BGL. All classes of soil except rocky (a) Depth not Exceeding 3m BGL |
| 357 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.a) Inside size 75x120 cm and 120 cm deep |
| 358 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.a) 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 359 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.a) 110mm o/d pipe |
| 360 | 160mm o/d pipe |
| 361 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 (150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.a) Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 362 | Plugging of The Existing Sewer Connection |
| 363 | Cleaning of Man Holes including cost of Labour & Material |
| 364 | Extra for making connections of all sizes newly laid sewers within benching of fully charged sewers including pluging of sewer, dewatering & desilting of manholes etc.a) with existing sewer of 300 mm id and below |
| 365 | Bt bill for connection with city sewer system (LS) |
| 366 | Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. (c) Boring with 250mm id Housing Pipe |
| 367 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (b) 150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness |
| 368 | Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore. (a) 150mm Steel Strainer (slot size 0.15/0.20mm) 5.0 mm thickness |
| 369 | Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect. |
| 370 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (b) 150mm internal diameter |
| 371 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 372 | Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis) |
| 373 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 374 | Collection of Sand sample & Sieve Analysis Report |
| 375 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. (b) 150mm internal diameter |
| 376 | Supply & Fixing of Ball Plug of MS Pipe complete with Inverted U-Hook attached to the Bottom Plug complete in all respect. 150mm Normal Dia (Wt. 21.6 kg/m) 5.4 mm Thickness |
| 377 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 378 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (a) Capacity of Air compressor 300 cfm at 250 PSI |
| 379 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-incharge |
| 380 | Rate for Tubewell to be abondened due to lack of Sufficient Water Bearing Strata or any other Reason |
| 381 | Providing & Fixing Sanitary Seal |
| 382 | Providing & Installing Testing & Commissioning of One No. Electrically actuated, Diaphram operated, Metering System, Chemical Dosing Chlorinating, suitable for delivering .5-6 ltr of Bleaching Powder solution / Sodium Hyro solution per hr under max Delivery Pressure upto 7 kgsqcm |
| 383 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. |
| 384 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). (d) 80 mm i/d |
| 385 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (a) Size 0.6 m x 0.6 m |
| 386 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earth work upto 1.5 m. Depth |
| 387 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. 25mm i/d |
| 388 | 20mm i/d for Standposts |
| 389 | Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. 20mm i/d Gun Metal peet valve heavy pattern. |
| 390 | 25mm i/d Gun Metal peet valve heavy pattern. |
| 391 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. (c) 25mm i/d G.I. Union |
| 392 | INTERNAL - EXPOSED ON WALL : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings with one step PVC solvent cement and testing of pipes complete as per direction of Engineer-in Charge.c) SDR 11 CPVC pipes & fittings 25mm o/d |
| 393 | Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 167 LPM against a head of 73 mtr (minimum 5.00 BHP).i) Moter with Pump |
| 394 | Providing & Fixing Electric Panel Board (ISI marked) Consisting of electric appliances such as Automatic star Delta Push Button, With Main switch, VM ampere Meter, E LCB, shunt capacitor, single phase Preconter, including lamps, Kit-kat etc. Complete in all respect. |
| 395 | P/F Iron Box for Control panel complete in all respect |
| 396 | P/F Submersible Cable 2.5 sqmm |
| 397 | P/F Submersible Cable 2.5 sqmm Double way passing through 63mm o/d PVC pipe of 4 kgf/sqcm under the ground with Manual Earth work. |
| 398 | P/F GI Column Pipe of suitable size min 50mm = 57m Rubber Gaskets, Nuts & Bolts complete in all respect. |
| 399 | Providing & Installing 80mm Dia delivery Main (from Tube Well to Duck Foot bend) including cost of CI/DF Pipes, DF Sluice Valves, DF NRV & specials as CI bends, V-Notch for Notch Houdi Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail