Tender For Repair/Maintainance To Pathway, Culverts, Interlocking Tiles & Certain B/R Works In Tech Area At Afs Tezpur
Tender Value
28 Lakhs
Estimated cost
Bid Submission
06 Jul 2026
3 days left
EMD
56000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tezpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintainance To Pathway, Culverts, Interlocking Tiles & Certain B/R Works In Tech Area At Afs Tezpur
BOQ
| Sl. No. | Item Description |
| 1 | Declogging and cleaning of floor trap/nahani trap/gully trap and clearing of blockage for clog free flowing of waste water upto the first manhole, complete all as specified and as directed. |
| 2 | Declogging and clearing of blockage of IWC/ EWC/ Urinal by removing chocked wastes/silt and mud etc., including removal of debris from site and washing down thoroughly for free flowing of waste upto 1st manhole and finally cleaning the washroom/toilet with clear water throughly or removal of debries/dirt etc., complete all as specified and directed. |
| 3 | Cleaning of sewage line, 100 mm bore, between manhole using the cleaning devices in compliance of Section 5 and protective gear and safety devices in compliance of Section 4 of 'The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act, 2013' and clearing of blockage for clog free flowing of sewage, complete all as specified and as directed. Note:- Center line length of the sewage line excluding the intermediate manhole(s) will be measured. |
| 4 | Cleaning of sewage line,150 mm bore, between manhole using the cleaning devices in compliance of Section 5 and protective gear and safety devices in compliance of Section 4 of 'The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act, 2013' and clearing of blockage for clog free flowing of sewage, complete all as specified and as directed. Note:- Center line length of the sewage line excluding the intermediate manhole(s) will be measured. |
| 5 | Bailing out water content in liquid/semi liquid state from sewage in septic tanks/ sewage sumps/manholes/ soakage pits etc upto the top of sludge level/aggregate fillings by using the mechanical cleaning devices in compliance of section 5 and protective gear and saftey devices in compliance of section 4 of \\"The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act 2013\\" by blocking temporarily the inlet line with suitable size wooden plugs and removing/discharging water content in liquid/semi liquid to a distance n exc 50 mtr away from starting point and depositing in pits not exc 10 sqm on plan and n exc 1.5 m in depth, returning filling in of pit after soaking of water including sprinkling of bleaching powder over the trenches and including necessary excavation and earth work in soft/loose soil complete all as specified and directed. |
| 6 | Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) laid bedded and pointed in any mortar, complete all as specified and directed. |
| 7 | Materials and Labour for plain cement concrete (1:4:8) Type D-2 using 40 mm graded aggregate, in foundations, filling and mass concrete including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 8 | Materials and Labour for plain cement concrete (1:3:6) type C1 using 20 mm graded aggregate as in surface channels and drains including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 9 | Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span,cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work including demolition of existing cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 10 | Materials and Labour for laying bricks, old size, sub class B, laid flat, in floors, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3, complete all as specified and directed. |
| 11 | All as per Serial Item No. 10 here in before but except bricks, complete all as specified and directed. |
| 12 | Materials and Labour for brickwork with sub-class ‘B’ bricks in brick-on-edge walls (less than ½ brick thick), built in cement mortar 1:4, complete all as specified and directed. |
| 13 | All as per Serial Item No.12 here in before but except bricks, complete all as specified and directed. |
| 14 | Raking out joints/ pointing to brick work in walls or to bricks on edge in floors,surface channels, roofs, etc. to bricks laid flat or brick tiles in pavings built in cement or cement lime mortar including flush pointing to brick walls in cement mortar (1:4), Complete all as specified and directed. |
| 15 | Raking out joints/ pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc.built in cement or cement lime mortar including flush pointing to bricks laid flat or brick tiles in pavings in cement mortar (1:4) , complete all as specified and directed. |
| 16 | Excavation in trenches n.exc 1.5 m wide and n exc 1.5 m depth for foundation laying cables etc or shaft, wells, cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and as directed. |
| 17 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil under floor, complete all as specified and as directed. |
| 18 | M&L for NP3 drain pipe 150 mm internal dia grade A laid in trenches and jointed in cement mortar after demolition and breaking up drain pipes set in cement mortar, complete all as specified and directed. |
| 19 | M&L for PCC type C2 (1:3:6) for concrete bed to drain pipes for 150 mm internal dia including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 20 | M&L for NP3 drain pipe 100 mm internal dia grade A laid in trenches and jointed in cement mortar after including demolition and breaking up drain pipes set in cement mortar, complete all as specified and directed. |
| 21 | M&L for PCC type C2 (1:3:6) for concrete bed to drain pipes for 100 mm internal dia including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 22 | Supply and Fix, 110 mm bore UPVC (SWR) pipes, single socketed in any length with rubber ring joints, fixed to walls including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed. |
| 23 | Supply and Fix, 110 mm bore PVC (SWR) bends any radius, complete all as specified and directed.Notes:- (i) The existing fittings are deemed to be taken down along with the SWR pipe.(ii) Old unserviceable fittings will be sold to the Contractor under relevant item in Schedule of Credit. |
| 24 | Materials and Labour for rendering 15 mm thick in cement mortar (1:6) on surface fair face of brickwork and finishing surface even and smooth using extra cement, including taking down cement plaster, any description on brick or stone walls/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. (drain) |
| 25 | Brick work with sub class 'B' bricks, straight or curved on plan, exceeding 6 metre mean radius built in cement mortar 1:6 including Demolition of brick work or stone masonry built in cement mortar, complete all as specified and directed. |
| 26 | M&L for Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement, complete all as specified and directed. |
| 27 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 28 | Materials and Labour for 100 mm thick plain cement concrete (1:3:6) type C2 using 40 mm graded aggregate as in sub base in floor/paving/ hardstanding, complete all as specified and directed. |
| 29 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; incl. dismantling etc of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and directed. |
| 30 | Materials and Labour for chequered cement concrete tiles with using grey cement and pigments, 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6), Incl. dismantling of tiles of any sizes and thickness, complete all as specified and directed. |
| 31 | Supply and fix Bird/Monkey Proofing UV stabilized HDPE Nylon Net wire mesh having thickness of 2.0mm to 3mm wire at walls and ceiling at a height upto 12.00 mtre from ground level. Notes(1) Contractor should ensure safety of worker and also arrange scaffolding/ manually operated ladder etc., complete all as specified and directed. |
| 32 | Cleaning of drains by removing silt, taking out brick bats, pebbles, muds, clay sludge etc from the bottom of drain and culvert bed and removing to a distance not exc 50 m and deposited where directed, complete all as specified and directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysJul 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender