| 1 | Surface dressing not exceeding 15 cm deep in soft/ loose soil and site clearance complete all as specified and directed. |
| 2 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed. |
| 3 | M&L Plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&L use and waste of timber as in formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for flat rough finished surfaces of concrete complete all as specified and directed. |
| 5 | M&L for use and waste of Formwork to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc to flat rough finished surfaces of concrete complete all as specified and directed. |
| 6 | M&L for use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions in square, rectangular and polygonal shape to rough finished surfaces of concrete complete all as specified and directed. |
| 7 | M&L for use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat rough finished surface of concrete complete all as specified and directed. |
| 8 | M&L Reinforced cement concrete (design mix) M-25 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | M&L for reinforced cement concrete (Design Mix) M-25 (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed |
| 10 | M&L for reinforced cement concrete (Design Mix) M-25 (20 mm graded aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 11 | M&L for reinforced cement concrete (Design Mix) M-25 (20 mm graded aggregate) Columns, pillars, piers, posts and struts complete all as specified and directed |
| 12 | M&L for reinforced cement concrete (Design Mix) M-25 (20 mm graded aggregate) Chajjas and the like complete all as specified and directed |
| 13 | S&F steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 14 | S&F steel TMT bars 5mm dia and over up to and including 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 15 | M&L Pre-Cast Cement Concrete block masonry type C1, 1:3:6 (using 20mm graded aggregate) with solid blocks exceeding 10 cm in width and setting in CM 1:4 complete all as specified and directed |
| 16 | M&L for damp proof course in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 17 | M&L for rendering 15 mm thick cement plaster on fair faces of brick work/ concrete in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 18 | M&L for rendering 10 mm thick cement plaster on fair faces of brick work/ concrete in cement mortar 1:6 finished fair and even complete all as specified and directed. |
| 19 | M&L for rendering 15 mm thick with cement mortar (1:4) mixed with water proofing compound @ 3% by the weight of cement on fair faces of brick work in external surfaces of wall finished even and smooth complete all as specified and directed. Note: Water proofing compound will be measured and paid separately. |
| 20 | Supply only integral water proofing compound complete all as specified and directed. |
| 21 | M&L for rendering 15 mm thick cement plaster on ceiling in cement mortar 1:3, finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub-base, sub-floors, plinth protection (alternate bays not exceeding 2.50 mtr length and joints to be filled with bituminous mastic filling) including finished even and rough complete all as specified and directed. |
| 23 | M&L for forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed. |
| 24 | M&L for Moorum/ red bajri filling in floors or paving, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 25 | M&L for hardcore of gauge not exc. 63 mm using broken stone or boulders, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed |
| 26 | M&L for 25 mm thick plain cement concrete 1:2:4 Type B0 (using 12.50 mm graded stone aggregate) as in sub-base finished even and rough complete all as specified and directed. |
| 27 | M&L for joint free Non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 28 | M&L for joint free Non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 29 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 30 | M&L for 15 mm thick screed bed or bedding a layer in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 31 | M&L for 10mm thick rendering in CM 1:4 as in backing coat to receive tile finish as in skirting and dados complete all as specified and directed. |
| 32 | M&L rendering 10 mm thick in CM (1:3) mixed with water proofing compound @ 3 % by weight of cement on roof surfaces finished even & smooth without using extra cement complete all as specified and directed.Note : WPC will be measured and paid separately. |
| 33 | Material and labour for water proofing treatment over RCC slab by applying bitumen primer @ 0.27 Lit/SqM conforming to IS 3384- 1986, provide and lay 4 mm thick APP modified membrane not less than 4.00 Kg/SqM , reinforced with non woven polyester matt weighing not less than 160 gm/SqM having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650 N/5cm ,tearing strength of 180 N , a static puncture resistance of 180, keeping minimum 10 cm side overlap and 15 cm end overlap and apply by torch application over a coat of blown grade hot bitumen grade VG-10 conforming to IS 702 heated to a working temperature of 180 centigrade and applied @ 1.2 kg/SqM of the surface area and finishing the top surface with solar reflective bituminous aluminium paint @ 0.1 Kg/SqM complete all as specified and directed by Engr- In- Charge . Note: (a) 10 years guarantee certificate to be submitted by the contractor. (b) Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialised agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 34 | S&F Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded complete all as specified and directed. |
| 35 | S&F Steel ventilator with top hung shutter including hinges, steel pegstay, complete all as specified and directed. |
| 36 | S&F mild steel framed work such as grills, gratings, etc.. with ends of barsshouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 37 | S&F 35 mm thick second class hardwood rail and style factory made shutters Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 38 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 39 | M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 40 | S&F 100 mm size butt hinges, extruded aluminium alloy with galvanisedmild steel hinge pin, anodised, type B-21 complete all as specified and directed. |
| 41 | S&F 300 mm length aluminium alloy, anodised, sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 42 | S&F 200 mm length aluminium alloy, anodised, sliding door bolt with hasp, staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 43 | S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 44 | S&F 150 mm long aluminium anodised barrel tower bolts of extruded section all as specified and directed. |
| 45 | Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 46 | S&F rotational moulded polyethylene water storage tanks of 500 ltrs capacity, triple layer (cylindrical vertical with closed top), white, hoisted and fixed in position all as specified in SSR Part I and connecting inlet, outlet pipe lines complete all as specified and directed. |
| 47 | S&F CPVC ball valve outer dia 20 mm complete all as specified and directed. |
| 48 | S&F vitreous china wash down water closet pan S and P trap (pedestal pattern), white including fixing bolt, plastic water closet seat, white, or black colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage etc complete all as specified and directed. |
| 49 | S&F 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and including 32 mm bore PVC flush pipe complete all as specified and directed. |
| 50 | S&F wash basin, vitreous china (flat back), size 630 mm x 450 mm, white including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 51 | S&F PVC connection 15mm dia 600 mm long with 2 Nos brass check nuts with washer etc complete all as specified and directed |
| 52 | S&F 32 mm dia PVC waste pipe 80 cm long with union for WHB/ Sink complete all as specified and directed. |
| 53 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 54 | S&F pillar taps of size 15mm bore dia, cast copper alloy, fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts screwed for iron pipe complete all as specified and directed. |
| 55 | S&F stop valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for unions or fixed for 15mm bore dia of pipe complete all as specified and directed. |
| 56 | S&F two way bib tap cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for 15mm bore dia iron pipe/ PVC pipe or for brass ferrule complete all as specified and directed. |
| 57 | M&L for 75 mm outer dia PVC (SWR) multi floor trap with grating includingjointing with solvent cement complete all as specified and directed. |
| 58 | M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed. |
| 59 | S&F 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, fixed to walls complete all as specified and directed. |
| 60 | S&F 75 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints or jointing with solvent cement, fixed to walls complete all as specified and directed. |
| 61 | S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and directed. |
| 62 | S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 63 | S&F soap dish stainless steel fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 64 | S&F PVC connections 15mm size, 450mm length with 02 Nos PTMT nuts with washer etc complete all as specified and directed. |
| 65 | M&L for preparation of new plastered wall surface with two coats of distemper oil emulsion over a coat of alkali resistant priming paint complete all as specified and directed. |
| 66 | M&L for preparation of new plastered ceiling surface with two coats of distemper oil emulsion over a coat of alkali resistant priming paint complete all as specified and directed. |
| 67 | M&L for finishing walls with acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 68 | Cutting into existing manholes for connecting new drains 100 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as require complete all as specified and directed. |
| 69 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/ dense soil complete all as specified and directed. |
| 70 | Removing excavated soil material to a distance exceeding 250 mtr but not exceeding 500 mtr complete all as specified and directed. |
| 71 | M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion (Anti-termite treatment) per square metre of surface complete all as specified and directed. |
| 72 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion (Anti-termite treatment) per square metre of surface area complete all as specified and directed. |
| 73 | Surface excavation not exceeding 30 cm deep and averaging 15cmdeep and getting out in hard/ dense soil complete all as specified and directed. |
| 74 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub-base complete all as specified and directed. |
| 75 | M&L for coloured and polished chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with grey pigment cement and pigments, including 20mm thick screed bed in CM 1:4 complete all specified and directed. |
| 76 | S&F 5 users LLDPE septic tank designed to carry sewage and sullage water including excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection, etc. complete all as specified and directed. |
| 77 | Earth work in excavation in all kind of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 78 | Earth work in excavation in ordinary rock by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 79 | Removing excavated rock material to a distance exceeding 250 mtr but not exceeding 500 mtr complete all as specified and directed. |
| 80 | M&L Pre-Cast Cement Concrete block masonry type C1, 1:3:6 (using 20mm graded aggregate) with solid blocks exceeding 10 cm in width and setting in CM 1:6 complete all as specified and directed |
| 81 | M&L for rendering 15 mm thick cement plaster on fair faces of brick work/ concrete in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 82 | M&L Plain cement concrete (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 83 | M&L for precast cement concrete 1:2:4 type B1, using 20mm graded stone aggregate as in manhole / Gully trap cover slab set in CM 1:4 including use and waste of necessary form work complete all as specified and directed. |
| 84 | S&F CRS TMT bars 10mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 85 | M&L for concrete bed to drain pipes 150/ 160 mm bore dia by using PCC (1:3:6), type C2 using 40 mm graded aggregate including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 86 | S&F 150 mm bore PVC (SWR) pipes single socketed, in any lengthwith rubber ring joints, including pipe fittings, ISI marked laid in trenches or in floors complete all as specified and directed. |
| 87 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. |
| 88 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft disintegrated rock complete all as specified and directed. |
| 89 | Removing surplus excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 90 | S&F 40 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 91 | S&F 25 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 92 | Cutting of existing UPVC 40 mm bore pipe line and inserting new tees, branches, etc. and connection to 40 mm bore UPVC pipe/ valve complete all as specified and directed. |
| 93 | Supply, laying and jointing 25 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 including UPVC fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 94 | Supply, laying and jointing 32 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 including UPVC fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 95 | M&L for road/ PCC/ chequered tiles/ hard surfaces cutting for laying pipes of any size and making good surfaces as per existing complete all as specified and directed. |
| 96 | M & L for construction of valve chamber of size 900 x900 x 900mm (outer dimensions) with PCC foundation in the ratio 1:4:8 type D2, brick work in cement mortar ratio 1:6 using of class 'B' bricks, PCC 1:2:4 type B0 using 12.5 mm aggregate at the top, plastering 15 mm thick in the ratio 1:4, including MS sheet cover 3.15 mm thick with angle iron frame 50x50x4 mm and locking arrangement complete with painting on steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. Please Enable Macros to View BoQ information |
| 97 | M & L for construction of valve chamber of size 900 x900 x 900mm (outer dimensions) with PCC foundation in the ratio 1:4:8 type D2, brick work in cement mortar ratio 1:6 using of class 'B' bricks, PCC 1:2:4 type B0 using 12.5 mm aggregate at the top, plastering 15 mm thick in the ratio 1:4, including MS sheet cover 3.15 mm thick with angle iron frame 50x50x4 mm and locking arrangement complete with painting on steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. Please Enable Macros to View BoQ information |