Housing Urban and Rular Development Local Bodies Closing in 1 days TDR #56026306

Tender For Renovation And Upgradation Work Of Rsp College At Belgaria, Dhanbad

Issued by Local Bodies · Belgaria T/s Dhanbad, Jharkhand
Tender Value
5.95 Crore
Estimated cost
Bid Submission
08 Jul 2026
1 days left
EMD
5.95 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Belgaria T/s Dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation And Upgradation Work Of Rsp College At Belgaria, Dhanbad

BOQ

Name of Work:- Renovation and upgradation work of RSP College at Belgaria, Dhanbad
Sl. No. Item Description
1Dismantling tile work in floors and roofs laid in cement mortar including stacking material with 50 metres lead: for thickness of tiles 10mm to 25mm
2Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
3Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work(Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.
4Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
5Dismantling of flushing cistern of all types (C.I./PVC/Vitreous china) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
6Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge: 15mm to 40mm nominal bore
7Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge: Above 40mm nominal bore
8Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge
9Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
10Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
11Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/I
12Taking down old door and window shutters including stacking serviceable materials with 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
13Taking down choukhat in doors including stacking serviceable materials with 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
14Taking down choukhat in windows including stacking serviceable materials with 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
15Providing designation 75 B brick work in C.M.(1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
16Providing designation 125 mm thick reinforced designation 75 A brick work in C.M.(1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
17Providing and laying in position cement concrete of specific grade excluding the cost of centering and shuttering-All work upto plinth level: 1:3:6(1 cement:3 coarse sand(zone-III):6 grade stone aggregate 20mm nominal size)
18Reinforced cement concrete work in beams, suspended floors,roofs having slope up to 15 deg landings,balconies,shelves,chajjas,lintels,bands,plain window sills,staircases and spiral stair cases above plinth level uo to floor five level, excluding the cost of centering,shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement:1.5 coarse sand(zone-III):3 graded stone aggregate 20mm nominal size)
19Centering and shuttering including strutting, propping etc. and removal of form for suspended floors,roofs,landings,balconies and access platform
20Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas,corbels etc, including edges.
21Providing Toe steel reinforcement of dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting,bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500(Only valid for SAIL & TATA STEEL): 8MM
22Providing Toe steel reinforcement of dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting,bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500(Only valid for SAIL & TATA STEEL): 10MM
23Providing Toe steel reinforcement of dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting,bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500(Only valid for SAIL & TATA STEEL): 12 to 32 MM
24Providing 6mm thick cement plaster(1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I.
25Providing 12mm cement plaster(1:4) in with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I.
26Providing 12mm thick cement plaster(1:6) in with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water,scaffolding,taxes and royalty all complete as per building specification and direction of E/I.
27Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I
28Providing and applying white cement putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
29Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required,scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
30Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required,scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
31Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives of required shade: New work (Two or more coats applied @1.43ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm)
32Providing and applying high quality acrylic modified resin based texture of Dholpur/Red stone pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @43.04kg/10 sqm to form film of 1-1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with premium acrylic smooth exterior paint with silicone additives of required shade by two or more coats @1.43ltr/10sqm, complete as the direction of engineer-in-charge.
33Providing and laying Double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc, complete. Size of tile 600x600 mm.
34Providing and laying 25mm thick Kotah stone slab flooring of approved size texture and colour over 19mm thick base of lime mortar(1:1:1)(lime putty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing,taxes and royalty all complete as per building specification and direction of E/I.
35Providing and laying 25mm thick Kotah stone tiles in risers of steps skirting and pillars of approved size texture and colour laid over 12mm thick cement mortar (1:30)(lime putty:surkhi:coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing,taxes and royalty all complete as per building specification and direction of E/I.
36Providing and laying finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20mm (average)thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified as directed by the Engineer-in-charge: Flamed finish granite stone slab jet black,cherry red, elite brown, cat eye or equivalent.
37Providing and fixing stone slab with table rubbed,edges,rounded and polished, of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth: Granite stone of approved shade.
38Providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% an conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4(1 cement:4coarse sand) jointing with grey cemet slurry @3.3kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel,plier,wedge,clips of required thickness,levelling system and rubber mallet for placing the tiles gently and easily.Glazed vitrified tiles Matt/Antiskid finish of size: Size of tile 600x600mm
39Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
40Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm
41Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand):Medium shade pigment using 50% white cement 50% Grey cement
42Extra for pre finished nosing to treads of steps of marble stone.
43Supplying,fitting and fixing good quality,well dressedand well seasoned sal wood work in chaukhat in doors and windows,skylight,fanlights and celetial window openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I.
44Supplying,fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formaldehyde synthetic resin both side commercial veneeres of standard make with oxidised iron fittings such as hinges,tower bolts,handle,cleats and sand blocks and taxes all complete as per building specification and direction of E/I
45Supplying,fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutters in doors and windows with black board core blended with high quality phenol formaldehyde synthetic resin both side commercial veneeres of standard make with oxidised iron fittings such as hinges,tower bolts,handle,cleats and sand blocks and taxes all complete as per building specification and direction of E/I
46Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.:1.5 mm thick
47Factory made prelaminated PVC rigid foam sheet 5mm thick
48Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
49Supplying, fitting & fixing M.S. grill made of 20 x 6 mm, M.S. flat as per approved design and drawing, properly fabricated with joints continuous, fillet welded and finished smooth, carriage of grill to work site hoisting as per building specification and direction of E/I ( where materials is not supplyed by the deptt.
50Supplying, fitting & fixing 20 gauge G.C.I. Sheet gate fitted on M.S.Angle frame of size 60x60x6mm including cost of fabrication, providing necessary blocking arrangementswith haskal and dommy dully fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per building specification and direction of E/I.
51Supplying,fitting,and fixing collapsible gate of approved size and make properly fabricated with vertical double channel 20x10x2 mm at 100mm. Centres andbraced with MS flat diagonals 20x3mm, with top and bottom rails of T iron 40x40x6mm with 38 mm dia steel pulleys complete with bolts nuts, locking arrangements,stoppers, handles,including applying a priming cost of red paint,carriage,hoisting and taxes all complete job as per building specification and direciton of E/I
52Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, cost of scaffolding and taxes all complete as per building specification and direction of E/I.
53Providing and fixing factory made Upvc glazxed/wire mesh windows/doors comprising of lead free Upvc multi-chambered frame,sash and mullion/coupler(wherever required) extruded profiles having minimum wall thickness of 1.70mm for series R1 and R2 profiles and 2.10mm for Series R3 and R4 profiles conforming to EN:12608 in any shape,colour and design duly reinforced with galvanized mild steel section made of required shape and size as per CPWD specification,uPVC extruded glazing beads,interlocks and inline sash adaptor (wherever required) of appropriate dimension, EPDM Gasket, hardware, SS 304 grade fasteners of minm 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367:Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc.Profile of frame,sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification and direction of Engineer-in-charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-charge.Wire mesh/glazing of plain/toughened/laminated/double glass unit with/without high performance coatings as per design requirements and conforming to IS:3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i)sites with basic wind speed >45m/sec as per IS 875-Part3 (ii)Sites with structure height more than 20m for all wind speeds. Three track three panels sliding window with two glazed and one wiremesh panels with aluminium channel for roller track,wool pile,nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above)x(40mm & above) & both glazed and fly screen sash(25mm & above)x (50mm & above) with zinc zlloy(zamak)powder coated touch locks with hook.(Height upto 1.2 metre).
54Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
55Water proofing for old and new roof slab:-Providing and laying water proofing treatment on roof slab by applying two component, factory designed ready to use, acrylic modified flexible material applied with brush,roller or spray for water proofing coating as per manufacturer specifications with following steps:-(a)Surface preparation:-Providing and cleaning of concrete surface to remove dust,oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour,tools complete.Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage.On identification of seepage, cement grouting to be done with non shrink expanding admixture of sika india pvt ltd/MYK schomberg.Dr fixit/fosroc or equivalent.Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mmx150mm fillet of mortar (Cement:sand-1:4) admixed with acrylic polymer of Sika/Fosroc/MYK schomberg/Dr fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer repairing surface irregularities, damaged concrete in base slab, dead cracks if any,with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material ,labour, tools,complete.(b)1st Coat:- Apply 1st coat of two component acrylic modified, ready to use, flexible cementetious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application , 45gsm of fibre glass cloth to lay when the 1st layer is still green. 1st coat should be applied @1.50kg/sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat:- To apply the 2nd coat of two component acrylic modified ,ready to use, flexible cementetious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7kg/sqmt/coat.For the purpose of measurement the entire treated surface will be measured.\\"After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage,leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C.The waterproofing coating to be protected from damage before screed over it. Waterfroofing brand: Sika topseal109hi/Fosroc brushbond RFX/Dr fixit pidiffin 2k/MYK aquafin TG product performance-chemical base PartA. Acrylic copolymer,PartB specially graded cementitious powder-density 1.6kg/l (mixed density)at+27 deg C Tensile strength-2N/sqmm after 28 days (with fibre cloth) according to ASTM D 2370 pullout bond strength-2N/sqmm(concrete failure)(According to ISO 4624) Slant shear bond strength=4N/sqmm(According to FIP 5.15) Elongation at break -35% without fibre cloth and 20% with fibre cloth(According to ASTM D 2370). (d) Protection of treated surface with PCC:- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3)with proper slope (1:120) towards the rain outlets in alternate panels of 2mlx2ml keeping 6mm gap between the panel joint.Integral water proofing admixture conforming to IS 2645 @100ml per bag of cement to be added in the screed concrete(paid sparately for this items) all corners shall be chamfered with 150mmx150mm fillet.The rainwater outlets shall be just levelled up with screed concrete to ensure smooth discharge of water-the perepheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd/MYK Schomberg/Dr fixit/Fosroc.For the purpose of measurement the entire treated surface will be maesured.\\" (e)Groove of PCC surface should be filled with polysulphide sealant(Paid separately) Brand-Sika India Pvt Ltd/MYK Schomberg/Dr fixit/Fosroc. Warranty for five years.
56Covering of treated surface with PCC:- Providing 25mm thick Cement concrete M20(1:1.5:3) maintaining slope in alternate 2mtx2mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 TO 3 including screening,shuttering and mixing cement concrete in mixer with admixture of integral water proofing and placing in position ,striking,curing,taxes and royalty all complete as per building specification and direction of EI.Panels that has been left should be casted next day.There should be 6mm gap between panels. Brand-Sika_plastocrate plus,MYK proof WP10, Fosroc-complast X421 ic, Dr fixit pidiprrof LW+.
57Providing and filling of 6mm thick groove between 25mm pcc panels with polysulphide sealant(poring grade) as per drawings and technical specifications and directions of EIC(with 18% GST). Brand:-Sika polysulphide,Fosroc-thioflex 600, Dr fixit pidiseal PS(42P),MYK Seal PS or equivalent.
58Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:110 mm diameter
59Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°110 mm bend
60Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)110 mm Shoe
61Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.:110 mm
62Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
63Providing 250mm wide brick drain in cement mortar(1:6) with av 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete(1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
64Making plinth protection 50mm thick of cement concrete 1:3:6(1cement:3 coarse sand(zone-III):6graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation,levelling& dressing& finishing the top smooth.
65Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.:12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
66New door with panelling
67Wall panelling
68Providing and fixing 6mm HPL sheet with all fittings,carriage,hoisting and taxes all complete as per building specification and direction of E/I.
69Providing and fixing S.S. Letters and taxes all complete as per building specification and direction of E/I.
70Carriage of materials: Brick- 7+1 km
71Carriage of materials:Sand-10km
72Carriage of materials:Stone chips-22km
73Carriage of materials:Stone Metal-22 km
74Point wiring in PVC conduit, with modular type switch Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required
75Group A Gr-C
76Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
77Circuit/submain wiring in PVC conduit Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.
782 x 1.5 sq.mm. + 1 x sq.mm. earth wire
792 x 2.5 sq.mm. + 1 x 2.5sq.mm. earth wire
804 x 6.0 sq.mm. + 2 x 6.0 sq.mm. earth wire
812 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
82Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
832 x 4 sq.mm.
84TV cable in existing conduit Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.
85S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.
86S/F PVC/G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.
8775mm x 75mm x 50mm deep/(4\\" x 4\\")
88S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.
895/6 amps, one way switch
9015/16 amps, one way switch
913 pin 5/6 amps, socket outlet
92TV antenna socket outlet
93S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
94Supplying and fixing Modular type blanking plate-Supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required.
95ITC Fluorescent fitting with down rods Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee.
96ITC ceiling fan Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required.
97ITC exhaust fan upto 450mm sweep Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
98S/F MCCB in cubical panel board: Supply and fixing following rating & capacity 4pole MCCB in existing cubicle panel board. Including drilling holes in panel, making connections etc as required.
9925 to 100A, 16kA fixed thermal rating( to be used as incomer for light & UPS SDB as floor, wall mounted panel)
100125A, 16kA fixed thermal rating( to be used as incomer for tap off bay of rising mains)
101160A, 35kA fixed thermal rating( to be used as incomer for SDB as floor wall mounted panel)
102200A, 35kA-(5 nos )fixed thermal setting with spreader links( to be used as incomer for tap off box of rising mains & 1 no for UPS room SDB)
103S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)
1048 way, double door
105S/F T.P. MCB DB Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1064 way (4+12), Double door, Horizontal type
1076 way (4+18), Double door, Horizontal type
108S/F 'C' series, MCB Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.
1096/32 amps, Single Pole
11040 amps, TΡΝ
11140 amps, DP
11250/63 amps, DP
113S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required
11440 amps
11580/100 amps
116Copper earth plate elecrtode Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)
117MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
118S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
119P/F GI lightning conductor final - Providing and fixing of Gl lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top. with 85mm dia 3mm thick copper base plate base including holes etc. complete as required.
120P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
121P/P G.I. lightning conductor tape in vertical run Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
122Led tube with batten 20W/22W:- Supply and fixing of wall mounted LED 20W/22W tube+batten electronic driver and accessories as required
12316\\"(400mm)Wall mounted fan
124LED bulb 9W/10W:-Supplying and fixing of LED 9W/10W bulb and accessories as required
12515/16 W Led Round down light
1261'x1' LED panel light
1272'x2' LED Panel light
12890/100W LED Flood light
129earthenware where footrest to be fixed in floor 15 mm C.I. Supplying, fitting and fixing viterous white glazed earthenware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. 580mm. long-with 10 litre low level PVC cistern
130Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms., 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/L. (A) With \\"P\\" trap (b) 10 lit. low level P.V.C. cistern
131Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/1. Flat back or standard corner (600mm x 350mm)
132Bib Cock (ISI Marked)
133Bib Cock (Long Thread) (ISI Marked)
134Soap Disk
135Central hole basin mixer (ISI Marked)
13615 mm C.P. extentsion Nipples
137Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. 600mm X 450mm size
138100 mm dia steel jali and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/l.
139Providing and fixing 15mm dia and 45cm. Long P.V.C. Connection pipe with heavy quality brass coupling at both ends etc. All complete as per specification and direction of Engineer-in-charge.
140Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
141Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/l Concealed work including cutting chases and making good the wall etc. 20 mm nominal outer dia Pipes
14225 mm nominal outer dia Pipes
143Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work: 25 mm nominal outer dia Pipes
14432 mm nominal outer dia Pipes
14540 mm nominal outer dia Pipes
146Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6) including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
147[Inferred from sub-totals: Continued entry for 8 Items of Inspection Chambers]
148Angular Stop Cock (Long Thread) (ISI Marked)
149Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri) with cover & locking system
150Towel Rail 24\\"
151Towel Ring
152Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm bowl depth 178 mm
153Providing and fixing N.P/ C.P. Brass/ P.V.C. Porcelain shower rose of 15mm inlet etc. All complete as per specification and direction of E/I. (c) 150mm dia C.P. Shower
154provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories, I.e lubricants, solventcement, clamp, ring, sockets etc.
155provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories, le lubricants, solventcement, clamp, ring, sockets etc.
156Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.75 mm Coupler
157110 mm Coupler
15875 mm Single pushfit Coupler
159110 mm Single pushfit Coupler
16075 mm Single tee with door
161110 mm Single tee with door
16275 mm Single tee without door
163110 mm Single tee without door
16475 mm Bend 87.5°
165110 mm Bend 87.5°
16675 mm Shoe (Plain)
167110 mm Shoe (Plain)
168Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
169Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
170Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
171Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
172Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
173Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
1741:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
175Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Foundation
176Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Column
177Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Lintel
178Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Chajja
179Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Beam
180Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Beam
181Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Stair
182Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Roof Slab
183Providing Toe steel reinforcement of 8mm dia rods as approved
184Providing Toe steel reinforcement of 10 mm dia rods as approved
185Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved
186Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
187Columns, Pillars, Piers, Abutments, Posts and Struts
188Lintels, beams, plinth beams, girders, bressumers and cantilevers
189Suspended floors, roofs, landings, balconies and access platform
190Weather shade, Chajjas, corbels etc., including edges
191Stairs, (excluding landings) except spiral-staircases
192Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
193Providing 50mm thick Damp Proof Course with cement concrete M-200 with nominal mix of (1:1.5:3) with approved quality of stone chips of 20mm to 6mm size graded and clean course sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with 5% cicio or any other approved water proffing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
194Providing designation 75B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, costs of screening, materials, scaffolding, raking out joints to 15mm depth curing taxes and royalty all complete as per building specification and direction of E/I.
195Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
196Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
197Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
198Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
199Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
200Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
201Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
202Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size.Size of Tile 600 x 600 mm
203Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.With commercial grade colour tiles.
204Providing and laying Double charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less then 0.08% and conforming to IS: 15622/ISO 13006 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement:4 Coarse sand0, jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with wite cement and matching pigments etc, complete Size of tiles 600 x 600 mm.
205Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
206Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
207Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
208Extra for pre finished nosing to treads of steps of marble stone.
209Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flat/ Square as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
210Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
211Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
212Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
213For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
214Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
215Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
216Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
217Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
218Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
219Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.5 mm thick
220Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
221Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
222Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend
223Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe
224Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
225Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
226Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
227Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.
228Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps :- (a) Surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jel including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc or equivalent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modilied repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to-use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Waterproofing Brand: Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance - Chemical Base Part A.Acrylic copolymer, Part B Specially graded cementitious powder - Density 1.6 kg/l (mixed density) at +27°C Tensile Strength - 2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength-2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4N/mm2 (According to FIP 5.15) Elongation at Break ~35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope (1:120) towards tlre rain outlets in alternate panels of 2 mlx2ml keeping 6mm gap between the panel joint. lntegral water proofing admixture conforming to lS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this ltems).-All corners shall be chamfered vrith 150mm X 150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheralmouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\" (e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc. Warrenty for five years.
229Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering,and mixing cement concrete in mixer with admixture of integral water proofing and placing in position,striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.-There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+
230Providing and filling of 6mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of Engg in Charge (with 18% GST).Brand:-Sika Polysulphide, Fosroc-Thioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivalent.
231Carriage of material:Brick - (7P +1K) km
232Carriage of material:Sand - (19P+1K) km
233Carriage of material:Chips - (24P+1K) Km
234Carriage of material:Metal - (24P+1K) Km
235Carriage of material:Cement - (10P) Km
236Carriage of material:Steel - (10P) Km
237Point wiring in PVC conduit, with modular type switch - Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as required Group A:Gr-C
238Power plug wiring in PVC conduit (2 x 4 sq.mm) - Wiring for light/power plug with 2 x 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
239Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire
2402 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire
2412 x 10.0 sq.mm. + 1 x 10.0 sq.mm. earth wire
2424 x 6.0 sq.mm. + 2 x 6.0 sq.mm. earth wire
243Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.2 x 4 sq.mm.
244TV cable in existing conduit - Supplying and drawing co-axial TV cable RG-6 grade copper conductor, PE insulated, with PVC sheath in the existing surface/recessed PVC conduit as required.
245S/F PVC conduit - Supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required.20mm
246S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.75mm x 75mm x 50mm deep/(4\\" x 4\\")
247S/F Modular type Switch / Socket: Supplying and fixing following modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc as required.5/6 amps, one way switch
24815/16 amps, one way switch
2493 pin 5/6 amps, socket outlet
250TV antenna socket outlet
251S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
252Supplying and fixing Modular type blanking plate-Supplying and fixing modular blanking plate on existing modular plate switch box excluding modular plate etc. as required.
253Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps 'C' series, SP MCCB, in sheet steel enclosure, on surface or in recess with chained metal cover for socket out let and complete with connections, testing and commissioning etc as required. Make : L&T/ABB/Legrand/Polycab/Philips
254Providing & fixing : Porviding and fixing of MV danger notice plate of 200mmX150 mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.
255S/F light plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 5 pin, 5/6 amps socket outlet and 5/6 amps piano tyep switch connection, painting etc. as required.
256S/F power plug point with modular type accessories - Supplying and fixing suitable size G.I./PVC box on surface or in recess with phenolic liminated sheet cover in front including providing and fixing 6 pin, 15/16 amps socket outlet and 15/16 amps piano type switch connection, painting etc. as requird.
257S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
258S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required.
259ITC fluorescent fitting directly on surface - Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
260ITC Fluorescent fitting with down rods - Installation, testing and commissioning of Pr-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement, 2 no. down rods of 20mm dia stee.
261ITC ceiling fan - Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq.mm. FR PVC insulated, copper conductor, single core cable etc. as required.
262ITC exhaust fan upto 450mm sweep - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
263S/F MCCB in cubical panel board: Supply and fixing following rating & capacity 4pole MCCB in existing cubicle panel board. Including drilling holes in panel , making connections etc as required.25 to 100A, 16kA fixed thermal rating( to be used as incomer for light & UPS SDB as floor, wall mounted panel)
264125A, 16kA fixed thermal rating( to be used as incomer for tap off bay of rising mains)
265160A, 35kA fixed thermal rating( to be used as incomer for SDB as floor wall mounted panel)
266200A, 35kA-(5 nos )fixed thermal setting with spreader links( to be used as incomer for tap off box of rising mains & 1 no for UPS room SDB)
267S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)8 way, double door
268S/F T.P. MCB DB - Supplying and fixing following way, three pole and netural, sheet MCB ditribution board, 415 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door, Horizontal type
2696 way (4 + 18), Double door, Horizontal type
270S/F 'C' series, MCB - Supplying and fixing following 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connection, testing and commossioning etc. as required.6/32 amps, Single Pole
27140 amps, TPN
27240 amps, DP
27350/63 amps, DP
274S/F four pole MCB isolator - Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioining etc. as required40 amps
27580/100 amps
276Copper earth plate elecrtode - Earthing with copper earth plate 600mmx 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. as required (But with charcoal or coke and salt)
277S/L 8 SWG copper wire in ground - Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth, including soldering etc. as required
278P/F GI lightning conductor final - Providing and fixing of GI lightning conductor final, made of 25mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate base including holes etc. complete as required.
279P/F G.I. lightning conductor tape in horizontal run - Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
280P/F G.I. lightning conductor tape in vertical run - Provding and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
281MV cable laying upto 120 sq.mm. in ground without sand and cover - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 185 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
282MV Cable :- Supply of ISI marked aluminium cable conductor XLPE PVC Insulated Cable as per I.S :7098 armoured , served shaelthed 1100V grade with Termination and laying of cable .
283Supply of ceiling fan :- Supplying and fitting of 1400mm sweep regular /standared model AC fan , including connection with 1.5 sqmm copper wire down rod of standered length ( upto 30cm ) with all acessories as required
284Supply of Exhaust Fan :- Supply and fitting of 300 mm , 230V AC metal exhaust fan in the existing opening including making good the damage , connection testing commisioning etc as required
285Supply of Exhaust Fan (15\\") for Kitchen :- Supply and fitting of 380mm (15\\") , 230V AC metal exhaust fan in the existing opening including making good the damage , connection testing commisioning etc as required
286Led tube with batten 20W/22W :- Supply and fixing of wall mounted LED 20W/22W tube+ batten electronic driver and acessories as required .
28716\\" (400 mm ) Wall Mounted Fan
288Led bulb 9W/10W :- Supplying and fixing of LED 9W/10W bulb and acessories as required .
28915/16W Led Round Down Light
2901' X 1' LED Panel Light
2912' X 2' LED Panel Light
29290/100 W LED Flood Light
293Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \\"p\\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.580mm. long - with 10 litre low level PVC cistern
294Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \\"p\\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \\"P\\" trap (b)10 lit. low level P.V.C. cistern
295Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm)
296Bib Cock ( ISI Marked )
297Bib Cock ( Long Thread ) ( ISI Marked )
298Soap Disk
299Central hole basin mixer ( ISI Marked )
30015 mm C.P. extentsion Nipples
301Angular Stop Cock ( Long Thread ) ( ISI Marked )
302Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system
303Towel Rail 24\\"
304Towel Ring
305100 mm dia steel jali
306Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
307Providing and fixing 15mm dia and 45cm. Long P.V.C. Connection pipe with heavy quality brass coupling at both ends etc. All complete as per specification and direction of Engineer-in-charge.
308Providing and fixing N.P/ C.P. Brass/ P.V.C. Porcelain shower rose of 15mm inlet etc. All complete as per specification and direction of E/I. (c) 150mm dia C.P. Shower
309Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. (b) Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. Brass revolving fitting 3mm ply wood board and C.P. Hinges to fix with mirror. (i) 600mm X 450mm size
310Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. Approved make supported on painted C.I. Or R.S. Bracket 32mm C.I. Brass waste, 15 mm dia C.I. Body brass spindle stop cock of approved quality of weight not less than 350 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plunber joints etc. all complete as per specification and direction of E/I.
311Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
312Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178 mm
313Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the wall etc..20 mm nominal outer dia Pipes
31425 mm nominal outer dia Pipes
315Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work25 mm nominal outer dia Pipes
31632 mm nominal outer dia Pipes
31740 mm nominal outer dia Pipes
318provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.
319provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.
320Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm Coupler
321110 mm Coupler
32275 mm Single pushfit Coupler
323110 mm Single pushfit Coupler
32475 mm Single tee with door
325110 mm Single tee with door
32675 mm Single tee without door
327110 mm Single tee without door
32875 mm Bend 87.5°
329110 mm Bend 87.5°
33075 mm Shoe (Plain)
331110 mm Shoe (Plain)
332Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L.
333(b) From 51.0 M to 150.00 M
334Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
335Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
336Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
337Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
338Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
339Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
340STARTER D.O.L starter with SS Enclosure with 380/415 Volt coil 5 to 10 HP
341Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
342Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
343Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
344Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
345Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stoneaggregate 40 mm nominal size)
346Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
347Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
348Providing TMT reinforcement of following dia rods as per approved design and drawing including carriage of M.S. rods of (Straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per building specification and direction of E/I.Providing Toe steel reinforcement of 8mm dia rods as approved
349Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved
350Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
351Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
352Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
353Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
354Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
355Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
356Providing 1.5mm cement punning including curing, carraige of water with all leads and lifts as per building specification and direction of E/I.
357Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
358Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
359Carriage of materials:Brick - 7 +1 km
360Carriage of materials:Sand - 10 km
361Carriage of materials:Stone Chips - 22 Km
362Carriage of materials:Stone Metal - 22 Km
363Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
364Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
365Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
366Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
367Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Roof slab
368Providing Toe steel reinforcement of 8mm dia rods as approved
369Centering and shuttering for Suspended floors, roofs, landings, balconies and access platform
370Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
371Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
372Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
373Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.In Recharge Well (Лr²h)
374Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge:In Recharge Well
375Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
376Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
377Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L.
378Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
379Carriage of materials:Brick - 7 +1 km
380Carriage of materials:Sand - 10 km
381Carriage of materials:Stone Chips - 22 Km
382Carriage of materials:Stone Metal - 22 Km
383Jungle clearance in borrow area, building premises, flanks and slope on the road, canals and embankment by removing the grass and jungle bushes from the top including weeding out shrubs small trees upto 150 mm dia. and their removal all complete job as per direction of E/I.
384Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, as per directions of Engineer in Incharge: All kinds of soil
385Supply , stacking & filling of good earth at site including cost of royalty & carriage upto 5 Km ( Earth measured in stacks will be reduced by 20% for payment ) .
386Supplying and stacking at site dump manure from approved source, including carriage up to 5 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
387Rough dressing the trenched ground including breaking clods.
388Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation
389Fine dressing of the ground.
390Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
391Mixing earth and sludge or manure in the required proportion specified ordirected by the Officer-in-charge
392Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
393Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge.
394Providing and Stacking of Anjeer of height 75-90 cm. in poly bags of size 25 cm as perdirection of the officer-in-charge.
395Providing and Stacking of Curry leaf of height 75-90 cm in poly bag of size 25 cm as perdirection of the officer-in-charge.
396Providing and Stacking of Ashwagandha of ht. 30 cm with multi branches in Poly bag of size 20 cm.as per direction of the officer-in-charge.
397Providing and Stacking of Kalmegh of ht. 30 cm with multi branches in Poly bag of size 20 cm. as perdirection of the officer-in-charge.
398Providing and Stacking of Adusha of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge.
399Providing and Stacking of Satavari, well developed in earthen pot of size 20 cm as per direction of theofficer-in-charge
400Providing and Stacking of Tulsi of ht. 30 cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge.
401Providing and Stacking of Alovera well developed in earthen pot of size 20cm as per direction of the officer-in-charge.
402Providing and Stacking of Bryophyllum of ht. 30cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge.
403Providing and Stacking of Lemon grass of ht. 30cm with multi branches in Poly bag of size 20 cm. as per direction of the officer-in-charge.
404Providing and Stacking of Karonda of ht. 45-60cm in Poly bag of size 25 cm. as per direction of the officer-in-charge.
405Providing and Stacking of Giloy well developed in poly bag of size 20 cm as per direction of the officer-in-charge.
406Providing and Stacking of Brahmi well developed in poly bag of size 20 cm as per direction of the officer-in-charge.
407Providing and Stacking of Sarpgandha well developed in poly bag of size 20 cm as per direction of theofficer-in-charge.
408Providing and Stacking of Mandukparni well developed in poly bag of size 20cm as per direction of the officer-in-charge
409Providing and Stacking of Steviea well developed in poly bag of size 20 cm as per direction of the officer-in-charge.
410Providing and Stacking of Aprajita Blue well developed in poly bag of size 20 cm as per direction of the officer-in-charge
411Providing and Stacking of Aprajita White well developed in poly bag of size 20 cm as per direction of the officer-in-charge.
412BENCH - ( Mtl Cast Iron Bench made up of 13 MS square tubes (50 mm X 25 mm) in length of 1500 mm size Decorative Stand / Legs MtlR (CAST IRON BENCH)
413Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
414Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
415Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
416Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
417Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
418Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
419Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
420Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 1 2 mm thick bed of cement mortar 1 :. 3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
421Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
422By Mix in Place Method:Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401.Rate per cum for grading-I Material
423Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
424Cast-in-Situ Cement Concrete M20 Kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409):PCC M20 for Kerb cast in situ
425Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
426Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
427Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
428Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
429Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
430Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
431Providing Toe steel reinforcement of 8mm dia rods as approved
432Providing Toe steel reinforcement of 10 mm dia rods as approved
433Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved
434Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
435Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 : 4 (1 cement: 4 coarse sand).Medium shade pigment using 50% white cement 50% Grey cement
436Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
437Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
438Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
439Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating not less than 275 gm/m2
440Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
441Flashings/ Aprons.( Upto 600 mm)
442Gutter (600 mm over all girth)
443Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
444Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 110 mm bend
445Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe
446Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
447Carriage of materials:Brick - 7 +1 km
448Carriage of materials:Sand - 10 km
449Carriage of materials:Stone Chips - 22 Km
450Carriage of materials:Stone Metal - 22 Km
451Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
452Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
453Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
454Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
455Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
456Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
457Providing and laying matt finished vitrified tile of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
458Carriage of materials:Brick - 7 +1 km
459Carriage of materials:Sand - 10 km
460Carriage of materials:Stone Metal - 22 Km
461Earthwork in exacavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removing roots of trees shrubs all complete as per approved design, building specification and direction of E/I.
462Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
463Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thicklawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in both directions In rows 5 cm apart in both directions
464Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
465Supplying & Stacking of Selection No.1/doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.
466Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
467VATS SPORTS 9.5 m Nylon Brown Volleyball Net VATS SPORTSR (VATS)
468cosco 8 Panel Single Colour Natural Leather Volleyball coscoR (cosco super volley)
469Stag Mild Steel Volleyball Pole of Height 8.5 foot foot StagR (STAG VOLLEYBALL TELESCOPIC POLE SUPREME)
470PUTEX Fibre Glass Volleyball Net Antennae PUTEXR (SG234)
471Carriage of materials:Brick - 7 +1 km
472Carriage of materials:Sand - 10 km
473Carriage of materials:Stone Metal - 22 Km
474Providing of PVC/ XLPE insulated sheathed heavy duty armoured power cable with aluminium conductor of 1.1kV (confirming to IS-1554 part-1) Make-Havells/ Finolex/ Polycab.2Cx6 sq.mm
4754Cx10 sq.mm
4763.5Cx70 sq.mm
4773.5Cx400 sq.mm
478Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning protective covering and refilling the trench etc as required of following sizes.upto 25 sq.mm
479upto 95 sq.mm
480upto 400 sq.mm
481Erection of Steel Pole upto 8m in CC: Erection of steel tubular pole of ;ength exceeding 6.5m but not exceeding 8.0m in cement concrete 1:3:6( 1cement:3coarse sand: 6 draded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required.
4827.0m height Octagonal Hot -dip glavinized pole(BOP-7030) :Supply, installation of 7.0m height OctagonalHot -dip glavinized pole with top dia 70mm, bottom dia 130mm & made of 3mm thick sheet, base plate dimension 200x200x12mm(L X B X T) including suitable sizes of foundation bolt all complete as required.( without arm)
4830.5m single arm suitable for 70mm top pole
4840.5m double arm suitable for 70mm top pole
485Supply and fixing of 25W LED street light fitting ,with die cast aluminium housing of ingress protection of IP65 and complete with all accessories etc on pole including connection and earthing the body etc as required.
486Gate Light for Main Entrance :- Providing and fixing, connection of intergal post top lamp for gate light 40W LED post top made in cast aluminium with decorative opal polycarbonate diffuser with IP:65 protection including all other accessories as per drawing provided at the time of work execution or as per the direction of E/I)
487LED Bollard Light: Providing anf Fixing of LED Bollard light decorative luminaire light fixture & LED lamp with foundation, commissioning, testing along with civil work with all other accessories as per drawing.
488Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
4894 X 10 sq. mm (25mm)
4903½ X 70 sq. mm (38mm)
4913½ X 400 sq. mm (50mm)
492Supplying and fixing Rewireable DP/TPN Switch Disconnector(SFU): S/F of the follwing way double pole / TPN sheet metal switch discooector fuse unit in existing metal board with rewireable type fuses, includin drilling holes in metal board, making connections etc as required. It will be wall mounted.( for Pump motor) 32A, TP&N
493S/F MCCB in cubical panel board - Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board, including drilling holes in cubical panel, making connection, etc. as required.25-100 amps, 16 KA, fixed thermal setting
494S/F busbar chamber - Providing and fixing following capacity busbar chamber with 4 strips of length 300mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body, etc. as required.200 amps
495S/F sheet metal ON/OFF Load changeover - Providing and fixing capacity 2 pole/4 pole ON/OFF load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required.63 amps, 2 pole
496S/F panel mounted changeover - Providing and fixing following capacity 4 pole panel mounted changeover switches in existing cubical panel board, making connection, earthing the body etc. as required.63 amps, 4 pole
497S/F S.P. MCB DB - Supplying and fixing following way, single pole and netural, steel sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)12 way, single door
498S/F 'B' series, S.P. MCB -Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, 'B' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required6/32 amps, single pole \\"B\\" series
49940 amps, single pole \\"B\\" series
500Labour Cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56026306
AUTHORITY Local Bodies
TENDER VALUE 5.95 Crore
LAST DATE 08-07-2026
Authority
Authority Name Jharia Rehabilitation And Development Authority
Work Description Tender for Renovation And Upgradation Work Of Rsp College At Belgaria, Dhanbad
Basic Detail
Tender No JRDA/CIVIL/26-27/08/126 Dated 13.06.2026
Bidding Type Tender
Location
City Belgaria T/s Dhanbad
State Jharkhand
Key Dates
Publish Date 17 Jun 2026
Submission Date 08 Jul 2026
Open Date 10 Jul 2026
Finance
Tender Value 5.95 Crore
Tender Fee 10000
EMD 5.95 Lakhs
Exemption Not Available
Document List
11289817-b199-46af-b830-a179dce8fd52.html
BOQ_155878.xls
eNIT08.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

11289817-b199-46af-b830-a179dce8fd52.html

xls

BOQ_155878.xls

pdf

eNIT08.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders