|
| 1 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified. |
| 2 | M&L for 15 mm thick rendering over surface other than fair face of brick-work or stone masonary surface with cement mortar 1:4 finished even & fair complete all as specified. |
| 3 | M&L for preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion(water based100%) over a coat of primer complete all as specified. |
| 4 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified. |
| 5 | M&L Brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified. |
| 6 | All as per item No. 5.00 above but except bricks complete all as specified. |
| 7 | Dismantling Asbestos cement (plain or corrugated, etc) sheets in roof coverings including ridge complete all as specified. |
| 8 | S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,in ridge fixed with self tapping screws complete all as specified. |
| 9 | S & F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in ridge fixed with self tapping screws complete all as specified. |
| 10 | Dismantling of wrought iron or mild steel work of any description & fixed in any position, complete all as specified. |
| 11 | S & F Rolled mild steel of Fe-290- Grade E-165 in gusset plates complete all as specified. |
| 12 | S&F rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W complete all as specified. |
| 13 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 CM thickness (below or above GL) complete all as specified. |
| 14 | M & L for Endura Designer Collection Series of Jhonson Tiles ,Kajaria or somani tile of size 300x300x10 mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 15mm thick base of cement mortar 1:4 in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete all as specified. |
| 15 | M/L100 mm thick Cement Concrete in floors PCC 1:4:8 type D-2 ( Using 40mm graded stone aggregate ) complete all as specified. |
| 16 | Supply only 25 mm thick fine aggregate(sand) for cushioning complete all as specified. |
| 17 | M&L 60mm thick factory made rubber mould interlocking paver block Grade of M-35 block any shape and size over and including 100 mm thick PCC 1:4:8 Type D-2 (Using 40mm graded stone aggregate complete all as specified. |
| 18 | M&L for chequered cement conc. Tiles 20cmx20cmx20mm set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 100 mm thick PCC 1:4:8 Type D-2 (Using 40mm graded stone aggregate) complete all as specified. |
| 19 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 complete all as specified. |
| 20 | Dismantling posts or struts (wood, steel or R.C.C.) embedded in natural ground any section, including taking out embedded portion and making good disturbed ground complete all as specified. |
| 21 | Dismantling fencing wire mesh, any type complete all as specified. |
| 22 | Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in soft/ loose soil complete all as specified. |
| 23 | M&L Cement concrete 1:3:6 Type C-2 ( Using 40 mm graded stone aggregates ) in foundations filling and mass concrete complete all as specified. |
| 24 | S&F MS work as in angle iron fencing post, fixed independently for fixing chain link fence, including all necessary cutting, drilling holes, bolting etc for screwing chain link fencing complete all as specified. |
| 25 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified. |
| 26 | Fixing only chain link fencing including line wires, any mesh size and type of standards rails straining bars etc incl provision of binding wire complete all as specified. |
| 27 | Dismantling Galvanised 2 standered Barbed wire any type complete all as specified. |
| 28 | S&F of Mild steel screw bolts (machine made) with hexagonal or square head at one head and rounded the other or screwed both end each screwed end to be fitted with washers and one hexagonal or square nut exc 05 cm but nexc 10 cm long dia of shank 05 to 10 mm complete all as specified. |
| 29 | S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins , etc. (each line wire to be measured ) complete all as specified. |
| 30 | All as per item No. 29 above but fixing only. |
| 31 | M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 32 | Material and labour for 5 mm thick plastering in CM With Nano fiiler 1: Cement 1: Sand 3 on concrete surfaces as in sides of column, lintel, beam, chajja, facia, railing, RCC wardrobe etc including finish the surface even and fair without using extra cement complete all as specified. Make:- I-Can Nano/Thermax/Shalimar |
| 33 | Material and labour for 20mm thick plaster in cement mortar with Nano wall filler 1: cement 1: sand 4 in two layers, i.e 10mm thick in each layer, top layer mixed with integral water proofing admixture as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified. Make:- I-Can Nano/Thermax/Shalimar Note :- WPC shall be supplied and paid separately. |
| 34 | Material and labour for rendering 15mm thick in cement mortar with Nano wall filler 1: cement 1: sand 6 on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified.Make:- I-Can Nano/Thermax/Shalimar |
| 35 | Supply only Nanotechnology based Elastomeric Hydrophobic Powder/admixture (EHP) powder for cement plaster and concrete complete all as specified. |
| 36 | Material and labour for exposing cracks more than 1mm wide with tile cutter and foming V groves not exc. 10mm wide and 10 mm deep in INSIDE RCC roof and filling Nanotechnology based Anti- corrosive with high strength Carbon fiber based Shorter chain epoxy Coating Perocess:a) Clean the Surface and open the crack and apply nano base Bond coatb) Mix with Nano wall filler with Bond coat and Fill the crackc) Apply Final Bond coat in the cracked surfaceMake:- I-Can Nano/Thermax/ShalimarNote : 1. Rate shall include for making surface clean,dustfree, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. Please Enable Macros to View BoQ information |