| 1 | Providing and Erection of self contained Drinking Water Cooler 150 CS/150 ltr. Capacity , Full Body made up of SS304 steel including all Connections and Materials with 1 year Warranty for Water Cooler and 2 year for Compressor of Approved Make like Bluestar / Voltas /Usha/Climatrol/Kelvinator to complete the job in all respect upto the entire satisfaction of Engineer –In-Charge (include all taxes) and Supply, Installation, Testing and Commissioning of Copper Wounded Voltage Stabilizer of Approved Make like Microteck/Luminous/V-guard 4KVA (Copper) 160-20 V High to Low cut off, suitable for Window/Split AC /Water Cooler etc. to complete the job in all respect upto the entire satisfaction of Engineer –In-Charge (include all taxes) and Supply, Installation, Testing and Commissioning of RO Unit of Approved Make like Aqua fresh/Kent/Live Pure etc. Of Capacity 50 LPH with 3 Nos Bowls plus 4 Membrane 100GPD, 2 Nos Booster Pump, 300 GPD Pre Filter Set , Auto Cut System with 1 year Warranty to complete the job in all respect upto the entire satisfaction of Engineer –In-Charge (include all taxes) |
| 2 | [10.26.3]Providing and laying of precast terrazzo tiles 20 to 22 mm thick with graded marble chips of size up to 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : 3. Dark shade pigment using ordinary cement [Through Rate] |
| 3 | [11.60]Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. [Through Rate] |
| 4 | [11.71.1]Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate] |
| 5 | [13.29.2]Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 2. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works [Through Rate] |
| 6 | [13.30.1]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 1. Hot finished welded type tubes [Through Rate] |
| 7 | [13.31]Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. [Through Rate] |
| 8 | [17.69.3]Interlocking Concrete Block Pavement 3. Providing and Laying 60 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 35 over the bed of 25 mm thick fine sand complete in all respect. [Through Rate] |
| 9 | [17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate] |
| 10 | [17.71]Relaying of available (removed and stacked) Interlocking Paver Block Pavement having thickness 100mm/80 mm/ 60 mm (average = 80mm) as per drawings and Technical Specification Clause 1504 [Through Rate] |
| 11 | [17.73]Construction of unreinforced plain cement concrete pavement in M-25 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORTH specifications [Through Rate] |
| 12 | [20.71.1]Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\\" (1200mm) [Through Rate] |
| 13 | [22.85.1]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 1. 15 mm nominal outer dia Pipes [Through Rate] |
| 14 | [22.96.1]Providing and fixing brass bib cock of approved quality : 1. 15 mm nominal bore [Through Rate] |
| 15 | [23.22.1.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.1. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. Double pole MCCB 16 to 63 Amp, 25 Ka [Through Rate] |
| 16 | [23.8.1.13]FITTING AND ACCESSORIES 1.13. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Socket size rotary step type Electronic regulator for A.C. ceiling fan [Through Rate] |
| 17 | [23.8.10.6]FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules [Through Rate] |
| 18 | [24.4.8.2]STREET LIGHT 8.2. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 4 Metre Long pole with top dia 65 mm and bottom dia 130 mm with base plate of size 225 x 225 x12 mm [Through Rate] |
| 19 | [24.5.1.2]MISCELLANEOUS ITEMS 1.2. Supply and jointing three core submersible flat cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for submersible pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge. Submersible Copper Cable 3 Core 2.5 sqmm [Labour Rate] |
| 20 | [26.463]Providing and stacking of Gardenia jasminoides of height 45-60 cm. with 3-4 branches in earthen pots of size 15 cm as per direction of the officer-in-charge. [Through Rate] |
| 21 | [26.58.1]Supply and installation of garden bench 1. Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100 mm, overall height 1000 mm, base width 620 mm. Back and seat shall consist of 5 Nos. reinforced concrete planks 1500 mm x 100 mm x 50 mm one plank 1500 mm x 200 mm x 50 mm. Seating height of the bench shall be 450 mm. The bench shall be fixed with nuts on concrete mount, all holes sealed after assembly and installation. All materials required to be as per BIS specifications. [Through Rate] |
| 22 | [26.63.2]Providing and fixing steel tree guard 2. MS circular tree guard with wire mesh, having 4 No. legs of angle iron size 25x25x3mm, 1.80 metre. height, 3 No rings of M.S Flats of 25 x 6 mm, 60cm dia and fixing of wire mesh size 50x75mm. Tree guard in two halves bolted together with 8mm dia & 30 mm long bolts, and fixing 250 mm X 100 mm iron plate, fixed in ground with 1:2:4 cement concrete, complete in all respects. Minimum weight should be 23 kgs [Through Rate] |
| 23 | [3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [5km] |
| 24 | [30.23.1]White washing with lime to give an even shade : 1. Old work (two or more coats) [Through Rate] |
| 25 | [30.9]Regarding terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-Charge. [Through Rate] |
| 26 | [34.57]Retro Reflective Printed Sign Board Facia with 10 year warranty Design, manufacturing and assembly of retro reflective sign face (measured in Sq. or rectangular shape) made from micro prismatic Type XI sheeting as per ASTM D-4956-09 pasted on 4mm thick ACP/ ACM. Special Inks used for printing letters/ legends/ directions/ theme shall be certified for low volatile organic compound emission & shall be water based ink (non solvent & non eco solvent ink) with durability of 10 years atleast. The reflective sheeting signage facia shall be covered with ultra voilet overlaminate transparant film. The signage facia shall be warranted for 10 years as per IRC 67 and shall be supplied with government test report of 3 year outdoor weathering test conducted in India condition on base reflective sheeting as per IRC 67-2012. [Through Rate] |
| 27 | [5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate] |
| 28 | [6.1.6]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) [Through Rate] |
| 29 | [6.15.1]Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) [Through Rate] |
| 30 | [6.16]Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). [Through Rate] |
| 31 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate] |
| 32 | [6.34.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more. [Through Rate] |
| 33 | [7.22.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate] |
| 34 | [9.22.1]Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1. 1.00 mm thick with zinc coating not less than 275 gm/m² [Through Rate] Please Enable Macros to View BoQ information |