| 1 | S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Make -Grandlay/Plaza/Kalinga/ Havells. (PS No. 501) UPSR -2018 |
| 2 | a)- 16 sq. mm 2 core |
| 3 | b)- 16 sq. mm 4 core |
| 4 | c)- 25 sq. mm 2 core |
| 5 | d)- 50 sq. mm 3.5 core |
| 6 | e) 70 Sq.mm. 3½ Core |
| 7 | S/F of Plain or Pin type copper tin plated cable socket (Lug) to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018a)-10 sq. mm |
| 8 | b)-16 sq. mm |
| 9 | c)- 25 sq. mm |
| 10 | d)- 35 sq. mm |
| 11 | e)- 50 sq. mm |
| 12 | f)- 70 sq. mm |
| 13 | g)-120 sq. mm |
| 14 | h)- 185 sq. mm |
| 15 | i)- 240 sq. mm |
| 16 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.1- 16 sq. mm 2 core (DSR-2018 9.3.1) |
| 17 | 2- 25 sq. mm 2 core (DSR-2018 9.3.2) |
| 18 | 3- 50 sq. mm 3.5 core (DSR-2018 9.3.19) |
| 19 | 4- 70 sq. mm 3.5 core (DSR-2018 9.3.20) |
| 20 | Supply of following sizes high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (KEI/Diatron/CCI/Gloster/ICL/Universal/Niccoo/Plaza/Polycab/Havells make) Complete in all respect as per direction of E/I. |
| 21 | 1. 120 sqmm x 3 Core (UPERC-2019 P-41) |
| 22 | 2. 185 sqmm x 3 Core (UPERC-2019 P-41) |
| 23 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Complete in all respect as per direction of E/I.1. 70 sq.mm (DSR-2018, 9.3.9) |
| 24 | 2. 120 sq.mm (DSR-2018, 9.3.11) |
| 25 | 3. 185 sq.mm (DSR-2018, 9.3.13) |
| 26 | 4. 240 sq.mm (DSR-2018 , 9.3.15) |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of upto 120 sq.mm to 400 sq.mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (DSR-2018) 8.1.1 |
| 28 | Upto 120 sq.mm to 400 sq.mm(DSR-2018) 8.1.2 |
| 29 | Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required . Complete in all respect as per direction of E/I.1. 3x70 sq.mm (DSR-2018, 10.2.1) |
| 30 | 2. 3x120 sq.mm (DSR-2018, 10.2.2) |
| 31 | 3. 3x185 sq.mm (UPERC-2019 P-28) |
| 32 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.(DSR-2018, 12.42) |
| 33 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. DSR Electrical 2018/ I. No. 11.3.3(8.0 metre and upto 10.0 metre) |
| 34 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 10.00 metre and upto 12.00 metreDSR-2018, 11.3.4 |
| 35 | Painting of the electric pole with 2 coats of aluminium paint after cleaning of pole. Complete in all respects as per direction of E/I. UPPWD-2018 P.S. No. 634 |
| 36 | S/E of overhead line with ACSR conductor on steel tubular poles incl.service bracket and binding etc. as UPPWD-2018 PS No. 627 |
| 37 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725(A) UPPWD-2018 |
| 38 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD-2018, PS 725B |
| 39 | S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) |
| 40 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete in all respect as per direction of E/I. DSR-2018, 14.16.1 |
| 41 | Analysis of Rates for laying of 90 mm dia DWC (Double Wall Corrugated) pipe across the road by Trenchless Method (Manual) |
| 42 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.complete in all respect as per direction of E/I. DSR-2018, 12.34 |
| 43 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paintUPPWD-2018, PS-623 |
| 44 | Supply & Fixing of XLPE Insulated Al. unarmoured Cable for working voltage for energizing the distribution boxes & Street light size of 1x16 sq.mm. complete in all respect as per direction of E/I. AOR |
| 45 | Supply & Fixing of XLPE Insulated Al. unarmoured Cable for working voltage for energizing the distribution boxes & Street light size of 1x25 sq.mm. complete in all respect as per direction of E/I. AOR |
| 46 | S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Make -Grandlay/Plaza/Kalinga/ Havells. (PS No. 501) UPSR -2018a)- 10 sq. mm 2 core |
| 47 | Supply and laying of 2.5 sq.mm 3 core copper conductor unarmoured cable. Complete in all respect. As per direction of E/I. AOR |
| 48 | S/F of Sintex Junction Box No-IIGSSJB2817 of Size 240x130x110 mm. Complete in all respect . AOR |
| 49 | Concrete with 4 cm gauge brick ballast, fine sand of 1.25 F.M. and cement , in proportion of 6 :3 :1 in foundation and under floors, including supply of all material, labour, tools & plant etc required completion of the Work. SOR- Item No-280 |
| 50 | Location and pin pointing of 11KV HT cable fault exposing the same in the underground 11 KV cables including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable Fault Locator) (AOR) |
| 51 | Location and pin pointing of LT cable fault exposing the same in the underground LT cables including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by Expert technical staff. (AOR) |
| 52 | Location and pin pointing of LT cable fault exposing the same in the underground LT cables including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by providing fault locator machines with operator (Cable Fault Locator) (AOR) |
| 53 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.DSR-2018 Item No.14.6 |
| 54 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 55 | S/F following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fusese, isolating switch metering instrument & instrument box with CTs etc.in case of TPN complete in all respects. a) 40 A TPN PS No-807 (F) |
| 56 | b) 15 A TPN PS No-807 (d) |
| 57 | Supply of Three Nos Electrician for Operation And maintenance for 12 month (32966x3=98898 per month) as per order No. Noida / DGM(civil) /2025 / 72 /Dt 10/01/2025 |
| 58 | Supply ofThree nos Helper for Operation And maintenance for 12 month (24370x3=73110 per month) as per order No.Noida / DGM(civil) /2025 / 72 /Dt 10/01/2025 Please Enable Macros to View BoQ information |