| 1 | Demolition of brickwork/stone boulders, masonary built in cement mortar incl all quoins, arches,pillars,etc. but excl ashlar facings, dressed stone works & precast concrete surfaces. as directed and specified. |
| 2 | M&L brick work with sub class 'B' bricks old size best quality bricks straight or curved on plan exc 6 M mean radius built in CM (1:4) all as specified and directed |
| 3 | Demolition of cement concrete in ground floors or pavings not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 4 | M & L Cement concrete type B1 (1:2:4) (20 mm graded aggregate) in surface channels and drains etc complete. |
| 5 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed. |
| 6 | M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping benching including necessary form work all as directed. |
| 7 | Taking down existing cement plaster on brick or stone walls/ceilling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and as directed |
| 9 | M&L for stone walling of random rubble stone masonary, uncoursed, well bounded, bedded & solidely hearted built in cement mortar (1:6) using locally available best stone complete all as specified and directed |
| 10 | All as per above item-09 but except stone (stone shall be obtained from demolition complete all as specified and as directed. |
| 11 | M&L Providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) as in steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham- fers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match complete all as specified. |
| 12 | M&L flush pointing to RR stone masonary un coursed in cm (1:4) complete all as specified and directed. |
| 13 | Extra over stone masonary for hammer dressing to face stone & face beds, joint with maxi depression on face from straight, edge held against the dressed surface nexc. 40mm thick for granite or trap basalt stone complete all as specified and directed |
| 14 | Removing mortar from and cleaning stones obtained from stone masonary of any description (except ashlar facings and dressed stone work stacking for measurement including all extra handling complete all as specified and directed |
| 15 | M & L for loose filling with aggregate of gauge 40 to 80 mm to cover weep holes complete all specified & as directed. |
| 16 | M&L for low density polythylene pipes (LDPE) 50mm bore of pressure rating 6Kg/cm square laid in retaining wall.Make :ISI or Approved . |
| 17 | Dismantling posts or struts (wood, steel or RCC) any section includin taking our embedded portion and making good disturbed ground (embedded in concrete, brick work, masonary etc) complete all as specified and as directed |
| 18 | M&L for hand rails, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flats iron fillets (for securing wire mesh etc ) similar work complete in repairs all as specified and as directed. |
| 19 | MM & L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation filling &mass concreting etc as specified and directed |
| 20 | S&F in repairs galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails bolts, including securing or tying at crossings with and provision of gavanised mild steel wire, staole or steel pins, etc all as specified & directed. |
| 21 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc., including provision of binding wire. complete all as specified and directed |
| 22 | M&L 10 mm dia MS TMT bar for fixing of chain link fencing with post complete all as specified and directed. |
| 23 | S & F of 11 to 15mm dia of neck MS Screw bolts(Machine made ) with hexagonal or square heads at one end and screwed at other end or both end, and screwed end to be fitted with washer and one hexagonal or square n.exc 20 cm long etc complete all as specified and directed. |
| 24 | S&F in repair galvanised concertina coil 610mm dia as in fencing on the top of angle iron including GI plain wire 3mm dia for holding coil complete all as specified and approved as directed. |
| 25 | M & L for preparation of new steel surface of any description over 10cm in width or girth and applying two coath of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 26 | Dismantling of floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store & rubbish of the premises.complete all as specified and directed |
| 27 | Demolition of stone slab to set paving of any description or thickness and laid dry or laid dry and pointed and removing serviceable stone/paver to store complete all as specified and directed |
| 28 | M&L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in subbase of flooring complete all as specified and directed |
| 29 | M&L for Endura (Parking Tiles) coloured tiles 7-8mm thick of size 300x300x7mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed |
| 30 | M&L for chequered cement concrete tiles with grey cement and pigment of size n exc 0.16 Sqm and minimium 25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified |
| 31 | M&L for 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled with sand complete all as specified and as directed. |
| 32 | M& L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 33 | M&L for 18-20 mm thick Black granite slab of approved quality of any size bedded and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15 mm thick screed bed in CM (1:4) including granite polish to be done by mechanical grinder and moulding edges complete all as specified and directed. |
| 34 | M & L for Providing cement concrete type B1 1:2:4 (20mm graded stone aggregate) in kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 35 | M&L for glazed ceramic coloured tiles for external surface of wall up to 1.20m height, area of each tile not exceeding 0.16 sqm as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thick backing coat on fair faces of brick work in CM (1:6) complete all as specified and as directed. |
| 36 | M&L for removal of land sliding material /snow/ debris by removing the same by JCB to a distance exc.50mtr and making the surface good complete all as directed. NOTE- (a) Per hours charge will be started when JCB will reached actual site only working hours will be measured and paid. |
| 37 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and directed. |
| 38 | Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 39 | S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. . |
| 40 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 41 | M&L in for MS steel Hollow Section work in tubular trussles, purlins, rafter, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 42 | M&L in for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 43 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 44 | M&L for Green/Blue powder coated 4mm dia wire mesh fence system perimeter coated welded wire mesh fence steel panel of area n.exc 10 Sqm and mesh size as directed by Engr-in-Charge complete all as specified and as directed. |
| 45 | M&L for Powder coated post for 3D fence including all clamps,bolts, fittings,fixtures and size of post as decided by Engr-in-Charge complete all as specified and directed. |
| 46 | M&L for stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the marble stone 10mm nominal size complete all as specified Note : (i) Payment for providing grooves shall be made separately (ii) Rate includes for any colour of marble stone and cement |
| 47 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and as directed. |
| 48 | S&F Aluminium Composite Panel (ACP) of any colour of exterior edge for cladding near entrance of Alucobond/Alstrong/Brand approved equivalent make for external wall / column / canopy cladding in combination of solid / Metallic colours, including all necessary frame work and complete weather sealing. The composite panel should consist of 3mm thermoplastic core of LDPE sandwiched between 2 skins of 0.5mm thick aluminium sheet (alloy designation 310S) making a total panel thickness of 3to4mm. The surface shall be furnished with Lumiflon based flourcarbon coating on top sides and service coating on reverse side. Coatings shall conform to specifications of ECCA /AAMA and conforming to the mechanical properties of panel as per detailed technical specifications. The system shall be fixed using GI brackets and stainless steel bolts and nuts complete with spring washers and cap nuts and all other necessary accessories. The bracket support shall be designed as per manufactures specification and shall withstand a wind pressure of 150 Kg/Sqm. All hardware shall corrosion resistant frame out of anodised aluminium member. Please Enable Macros to View BoQ information |