| 1 | Demolition of brickwork/stone boulders, masonary built in cement mortar incl all quoins, arches,pillars,etc. but excl ashlar facings, dressed stone works & precast concrete surfaces as directed and specified. |
| 2 | M&L brick work with sub class 'B' bricks old size best quality bricks straight or curved on plan exc 6 M mean radius built in CM (1:4) all as specified and directed. |
| 3 | Demolition of cement concrete in ground floors or pavings not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 4 | M & L Cement concrete type B1 (1:2:4) (20 mm graded aggregate) in surface channels and drains etc complete. |
| 5 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed. |
| 6 | M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping benching including necessary form work complete all as specified and as directed. |
| 7 | Taking down existing cement plaster on brick or stone walls/ceilling etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 8 | M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and as directed. |
| 9 | Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed. |
| 10 | S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165. complete all as specified and as directed |
| 11 | Dismentling/removal of damaged pre cast cover slab (cement concrete reinforcement/un-reinforcementof any size complete all as directed. |
| 12 | M&L precast cement concrete (1:2:4) type B-1 (using 20mm crushed stone aggregate as in Manholes cover slab all as directed (reinforcement shall be measured and paid separately) Set in Cm (1:4) complete all as directed. |
| 13 | S&F TMT bar 10 mm dia and over cut to length bent to shape required including cranking, binding spirally hooking end and binding with MS wire annealed not less than 0.9mm dia, complete all as specified and directed. |
| 14 | All as per item No 13 above item but 6 to 8mm dia complete all as specified . |
| 15 | M&L for Preparation of old/new steel surfaces exc 10cm width or girth and applying one coat of synthetic enamel paincomplete all as specified and directed. |
| 16 | S&F factory made steel fibre reinforced (SFRC) man holes covers with frames incl necessary hold fast/hooks (medium duty) of rectangularin size of equivalent area including fixing with CM 1:4 and not less than 50mm thickness complete all as specified and directed. |
| 17 | Dismantling of floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store & rubbish of the premises complete all as specified and as directed |
| 18 | Demolition of stone slab to set paving of any description or thickness and laid dry or laid dry and pointed and removing serviceable stone/paver to store complete all as specified and as directed. |
| 19 | M&L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in subbase of flooring complete all as specified and directed. |
| 20 | M&L for Endura (Parking Tiles) coloured tiles 7-8mm thick of size 300x300x7mm thick in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed. |
| 21 | M&L for chequered cement concrete tiles with grey cement and pigment of size n exc 0.16 Sqm and minimium 25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 22 | S&F Providing cement concrete type B1 1:2:4 (20mm graded stone aggregate) in kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed |
| 23 | M&L for glazed ceramic coloured tiles for external surface (Protection Tiles) of wall up to 1.20m height, area of each tile not exceeding 0.16 sqm as on vertical surfaces such as wall, dado ,skirting etc set and jointed in neat cement slurry and pointed with coloured cement to match over 10 mm thick backing coat on fair faces of brick work in CM (1:6) complete all as specified and as directed. |
| 24 | Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 25 | S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 26 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 27 | M&L in for MS steel Hollow Section work in tubular trussles, purlins, rafter, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 28 | M&L in for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified and as directed. Please Enable Macros to View BoQ information |