| 1 | Dismantling R.C. floor, roof, beams etc. includingcutting rods and removing rubbish as directedwithin a lead of 75 m. including stacking of steelbars.(a) In Ground floor including roofi) In Gr. floor Deputy Nursing Super Room |
| 2 | Cleaning the concrete surface by removing dirt and debris, marking defectivelocations and removing loose concrete by careful stripping untill hard surfaceis exposed, cutting the concrete to regular shape, wire brushing the exposedsurface and removing debris from site complete as per direction of theEngineer - in - Charge.At Ceiling |
| 3 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 4 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement excluding the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.b) 25 mm thick |
| 5 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.At walls |
| 6 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] |
| 7 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 8 | Brick work with 1st class bricks in cement mortar (1:4)a) In Superstructure. |
| 9 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor. |
| 10 | Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's pecification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)(a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick) |
| 11 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall ,With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(B) Wall .(b) Area of each tile above 0.09 Sq.m(i) Coloured decorative i) In gr floor |
| 12 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straighening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.i) Tor steel/Mild Steel (SAIL/ TATA/ RINL)(a) For works in foundation and upto roof of 1st floor/upto 4 m |
| 13 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 14 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes.(i) Pakur Variety |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i) With 1:6 cement mortar(b) 20 mm thick plaster Inside plaster |
| 16 | (ii) With 1:4 cement mortar (c) 10 mm thick plaster i) In 2nd foor |
| 17 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 18 | Supplying fitting and fixing I.R.C. fabric mesh with covering battens includingcost of screws etc complete (excluding the cost of battens).In ground floor(i) 25mm x 25mm x 2.7mm x 2.7mm ceiling covering |
| 19 | Welding in M.S. structural work with gas or electric:(a) Tack weld |
| 20 | Supplying, fitting and fixing in position fibre glass panes of approved quality with resin, nail, clip etc. as per IS:12866-1989. (In all floors for internal wall & upto 6 m height for external wall)(d) 3.0 mm thick (5.10 Kg/Sq.m) |
| 21 | (b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) |
| 22 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)(a) One Coat ii) Solvent based interior grade Acrylic Primer |
| 23 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)ii) Luxury Quality |
| 24 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 ofapproved make and brand fitted and fixed as per design as per approval anddirection of Engineer-in-Charge. [excluding the cost of supporting frame workand teak wood batten/Lipping]In gr floor(vi) 12mm |
| 25 | Supplying, fitting & fixing factory made foam PVC (density shall not be less than600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mmmade off with 5mm thick extruded foam PVC sheet, mitre cut at junction ofhorizontal and vertical member and joined them by heat welding. Entire doorframe profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mmM.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to beprovided at the exposed surface and three nos 5mm thick PVC sheet to beprovided as gap insert. The door frame to be fixed with wall by using 8mm dia.and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos.screws to be provided for each vertical member & 2 nos. for horizontal memberall complete as per direction of Engineer-in-Charge.(b) Pre-laminated Colour |
| 26 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory madesolid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S.frame shall have cost of steel primers of approved make and manufacture, M.S.frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheetout of which 75 mm shall be flat and 20 mm tapered in 45 degree on the innerside to form top & bottom rail and 115 mm wide PVC sheet out of which 75mmshall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom railsheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined togetherwith solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which isto be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. |
| 27 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 200mm Length |
| 28 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(viii) 100mm. X 75mm. X 3.50mm.Add Extra 30% for Oxidised Fittings) |
| 29 | Iron socket bolt of approved quality fitted and fixed complete.(c) 150mm long x 10mm dia bolt. |
| 30 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 31 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 32 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 33 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary :a) On timber or plastered surface : With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)same as priming area |
| 34 | on steel or other metal surface (iv) Two coats (with any shade except white)same as priming area |
| 35 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes15 mm |
| 36 | 25 mm |
| 37 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 38 | (B) Fittings(ii) Plain Tee , 110 mm |
| 39 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).(vii) 15 mm dia |
| 40 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats ofapproved paint.(iii) 630 mm X 450 mm size |
| 41 | Constructing Inspection pit of inside measurement 600mm X 600mmX upto 600mm(depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chipsover a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to insidewalls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit,providing necessary invert with cement concrete (1:3:6) with stone chips as perdirection, neat cement finishing to entire internal surfaces, top of the pit covered with100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcementsupto 1% and shuttering including 6 mm thick cement plaster (1:4) in all externalsurfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved makesupplied, fitted and fixed in the slab with necessary fittings, necessary earthwork inexcavation in all sorts of soil, filling sides of the pit with earth and removing spoilsafter work complete in all respect with all costs of labour and materials . i) With Pakur variety. (SAIL/TATA/RINL) |
| 42 | Supplying, fitting and fixing in position reinforced cement polymer concretemanhole /gully pit cover with matching frame.As per I.S-12592(M.D)(viii) 5 MT load bearing capacity gully pit cover with frame and hinge arrangement for opening of sizeCover: 470 mm X 420 mm X 80 mmFrame: 590 mm X 550 mm X 170 mmopening: 380mm x 305mmWeight: 100 kg (approx) |
| 43 | (ix) Light duty gully pit cover (yard gully) with with frame and hingearrangement for opening .Cover: 300 mm X 275 mm X 30 mmFrame: 450 mm X 375 mm X 75 mmopening: 300mm x 225mmWeight: 43 kg (approx) |
| 44 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap |
| 45 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 46 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C(ii) Plastic (hallow type) white |
| 47 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecess ary fixing materials and clamps complete.i) Polythene Flush Pipe |
| 48 | Supplying, fitting and fixing bib cock or stop cock.(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 49 | (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). |
| 50 | Supplying, fitting and fixing shower of approved brand and make.(a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 51 | (c) Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model - Tropical / Sumthing Special of ESSCO or similar). |
| 52 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond thecompound, in conformity with the Municipal /Corporation Rules for such disposal, loading intotruck and cleaning the site in all respect as perdirection of Engineer in charge Please Enable Macros to View BoQ information |