| 1 | Clearing and Grubbing Road Land |
| 2 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per MoRTH Specification Clause 201. By Mechanical Means, In area of non-thorny jungle |
| 3 | Hydraulic Excavator 0.9 cum |
| 4 | Supplying, filling and stitching of empty cement bags either of plastic or jute with earth available at site, of weight not less than 40 Kg., including excavation etc. complete. |
| 5 | Providing and filling joint sealing compound in CC Pavement/Structures as per drawings and MoRTH specifications with coarse sand and 6 per cent bitumen by weight |
| 6 | Supply & Fixing of flood gauge (water Gauge) as per I.R.C. 67 standard 200 cm long fixed on angle iron posts 50x50x6 mm, 2.6 M. long. |
| 7 | Construction of speed breaker of IRC standard having width of 3.70 M including cost of stone aggregate (50-25mm) size hire charges for roller for consolidation and compaction and other machines required for the work (including cost of bitumen) |
| 8 | Marking Centre Line and stop lines etc. on road as per IRC pattern with thermoplastic paint of approved quality and make with 8% glass beads laid on the road surface at temperature 160\\" C with a special applicator machine complete with a special applicator machine complete with labour material and traffic diversion arrangements. |
| 9 | White washing of parapet walls of CD work and tree truncks |
| 10 | White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per MoRTH specifications Clause 800 |
| 11 | Painting on Steel Surfaces |
| 12 | Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and MoRTH Specification Clause 801 |
| 13 | Supply of Caution Diversion sign board size 1800 x 600 mm having centre height of 75 cm made out or 1.25 mm thick M.S. sheet duly framed with angle iron size 40 x 40 x 5 mm fixed on two moving wheels and stands, made out of 75 x 40 mm channel having two solid rubber wheels mounted on ball bearings, boards is processed in stoving enamel blue and machine cut sheet reflective letter and arrow on one side and the other side having arrow only complete in all respect. |
| 14 | Painting with superior grade enamel paint of approved quality to give an even shade including writing lettering figuring etc. complete as per IRC standers of Bollards with 3 Nos. reflective type 7 cm wide strips including cost of providing new strips. |
| 15 | Painting old work (Complete Rate) |
| 16 | Printing New Letters and Figures of any Shade |
| 17 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and MoRTH Specification Clause 801 |
| 18 | Hindi (Matras commas and the like not to be measured and paid for. Half letters shall be counted as half only) |
| 19 | English and Roman |
| 20 | Excavation for Structures, Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. |
| 21 | Ordinary soil, upto 3m depth |
| 22 | Stone masonry work in cement mortar in foundation complete as per drawing and MoRTH specifications Clauses 1402, 1405, 2102 & 2104. Random Rubble Masonry, In 1:4 cement mortar |
| 23 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104, P.C.C grade M 10, Nominal mix 1:3:6 |
| 24 | Plastering with cement mortar (1:4), 20 mm thick on Stone work. |
| 25 | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6, 75mm thick |
| 26 | Restoration of Rain Cuts, Restoration of rain cuts with soil, moorum gravel or a mixture of these, clearing the loose soil, benching for 300mm width laying fresh material in layers not exceeding 250 mm and compaction with plate compactor or power rammer to restore the original alignment, level and slopes as per drawings and MoRTH specifications Clause 3002 |
| 27 | Mechanical Means |
| 28 | Granular Sub-Base with Coarse Graded Material (Table:- 400- 2) Construction of granular sub-base by providing well graded material, spreading in uniform layers with Tractor Mount Grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MoRTH Specification Clause 401. For Grading III Material |
| 29 | Wet Mix Macadam material. Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400-12 & 400-13 and MoRTH Specification Clause 406. By Mechanical Means with all lead |
| 30 | Maintenace of bituminous surface road, Repair to pot holes and removal of loose material, trimming of sides, cleaning of surface by providing tack coat, 13mm thick pre-mix carpet and seal coat type B as per MoRTH specification Clause 3004.2 |
| 31 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. |
| 32 | Cement Concrete Pavement, Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 602.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a concrete mixer of not less than 0.5 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed Side Formwork (steel channel, laying and fixing of 150 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using water finishing to lines and grade as per drawing and MoRTH Specification Clause 602 including vaccum dewatering process with allrequired equipments (Dowel Bars will be paid seprately) |
| 33 | Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row , Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. |
| 34 | 300 mm Please Enable Macros to View BoQ information |