| 1 | Excavation in trenches n. exc 1.50m wide and n. exc 1.50m in depth in any type of soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc and getting out complete all as specified and directed |
| 2 | Excavation in trenches exc 1.50m but not exc 3.00m in depth for foundation or shafts,wells,cesspits,manholes,pier holes,cable laying,sewage/water lines etc complete and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning filling in any type of soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed |
| 4 | Removing excavated material (Soils) to a distance n. exc 50m and depositing where directed at a level n. exc 1.50m above the starting point complete all as specified and directed |
| 5 | S&F in repairs 150 mm internal dia Grade 'A' salt glazed stoneware drain pipes, laid in trenches and jointed in CM (1:1) complete including demolition and breaking up existing drain pipes (salt glazed ware, AC or RCC) of 150 mm bore, removal of debris and disposal, complete all as specified and directed. |
| 6 | M&L for 200mm bore/inner dia Double wall corrugated (DWC) pipe (SN-4) with intergral socket and all necessary fttings, laid in trenches jointed as per manufacturer instruction confirming to IS 16098 (Part 2) complete all as specified and directed. |
| 7 | M&L for concrete bed in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in bed with thickness of bed below the barrel of pipe as 100mm and width of bed as 450mm to sewage pipes of 150mm internal dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 8 | Cutting into existing manholes for connecting new drains 150mm dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed |
| 9 | Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed |
| 10 | M&L for brick work with using sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 11 | M&L for honey comb brick work with using sub class 'B' bricks in one brick thick, straight or curved on plan n. exc 6m mean redius built in CM 1:4 complete all as specified and directed |
| 12 | M&L for brick work with using sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed |
| 13 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed |
| 14 | M&L for cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed by the Engr-in-Charge |
| 15 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole complete all as specified and directed |
| 16 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, retaining wall etc on the top of the brick masonary including necessary form work complete all as specified and directed |
| 17 | M&L for 75mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in plinth protection/path/hardstanding laid in panels, finish the top surfaces even and smooth without using extra cement complete including filling the joints with mastic compound all as specified and directed |
| 18 | Forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed |
| 19 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 20 | M&L for 15mm thick cement plaster in CM 1:4 on fair face of brick walls or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for 15 mm thick rendering in cement mortar 1:4 in two layers (10 mm thick undercoat and 5 mm thick finishing coat), mixed with and including Dr. Fixit Pidiproof LW+ (101) / make as per Particular Specification (list of Make) integral waterproofing admixture @ 200 ml per bag of cement, over and including two coats of Dr. Fixit Super Latex 302 / make as per Particular Specification (list of Make) applied in the proportion of 1 part Super Latex : 4 parts water : 7 parts cement, @ 1.50 kg of homogeneous mixture per square metre, finished even and smooth without the use of extra cement on external wall surfaces complete including aking down existing cement plaster on brick or concrete surfaces, including raking out joints, hacking for key, scrubbing down with water, etc., and removing debris complete all as specified and directed. |
| 22 | M&L for applying two coats of cement base paint after preparation of newly plastered/concrete surfaces over alkali resistant primer on wall including preparation of surfacescomplete all as specified and directed. |
| 23 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 24 | M&L for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed |
| 25 | Form work to soffits of suspended slab such as roof slab and similar work n. exc 200mm thick (horizental or sloping) rough finished flat surface complete all as specified and directed |
| 26 | M&L for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary form work, set in CM 1:4 complete all as specified and directed Note : TMT bars shall be measured and paid for separately. |
| 27 | S&F mild steel framed work framed work as in doors or gates of angle or Manhole Cover ,other section with gusset plates, rails, braces, grill etc., complete, drilled for fixing of stesheetinorother covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing comp in manhole cover frames conforming to Fe 410-W (Gde-E-250) quality 'A' complete all as specified and as directed |
| 28 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 29 | S&F welded steel wire fabric weight n. exc 4 Kg per Sqm suitable to weld with steel members complete all as specified and directed by Engr-in-Charge |
| 30 | M&L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge |
| 31 | S&F in repairs PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved solvent/adhesive and fixed to floor/wall or laid in trenches complete all as specified and directed |
| 32 | S&F in repairs PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe 75 mm dia with dia of outlet 75mm complete all as directed Make : Kisan/Prince/Supreme |
| 33 | Removing building materials etc to a distance of 1km in low laying MoD area or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed |
| 34 | S&F factory made steel fibre reinforced concrete (SFRC) manhole cover with frames, medium duty, 560 mm dia clear opening or rectangular cover of equivalent area, including necessary holdfasts/hooks and fixing in cement mortar 1:4, cover not less than 50 mm thick, complete all as specified and directed. |
| 35 | S&F factory-made steel fibre reinforced concrete (SFRC) manhole cover (without frame), medium duty, 560 mm dia clear opening or rectangular cover of equivalent area, including necessary holdfasts/hooks and fixing in cement mortar 1:4, cover not less than 50 mm thick, complete all as specified and directed. |
| 36 | S&F fibre reinforced polymer (FRP) chamber cover and frame, 2.5 tonne load capacity, size 300 mm × 300 mm, fixed in position complete all as specified and directed. |
| 37 | M&L for providing precast cement concrete (1:2:4) louvers and jallies 50 mm thick (measured solid) including all mouldings but excluding frame & set in CM 1:4 complete all as specified and directed. |
| 38 | Dewatering of sewage water from septic tank, soakage well or manhole of any size, depth and capacity by means of sewage tanker fitted with pump (5000 litre capacity), including collection, loading, transportation and disposal of sewage outside MoD land, complete all as specified and directed. |
| 39 | Desludging of septic tank/soakage well of any size and depth by mechanical pumping after plugging inlet, including removal of effluent, sludge and solid contents, loading, transportation and disposal outside MoD land. The item shall also include opening of septic tank/soakage well covers and reinstating the same to their original position after completion of work complete all as specified and directed.Note: Measurement shall be taken after dewatering of the tank, and only the solid/sludge content shall be measured for payment. |
| 40 | Cleaning of manholes of any size and depth, including cleaning the mouths of inlet and outlet pipes, removing accumulated silt, sludge, soil and other deposits by mechanical means, including opening of manhole covers and reinstating the same to their original position after completion of work, complete all as specified and directed. |
| 41 | Cleaning of existing sewage pipe lines of 100 mm/ 150 mm / 200 mm internal dia at any depth through manholes by means of hydraulic jetting pressure machine, including opening of manhole covers, removal of sludge, silt, solid deposits and liquid materials from sewer lines and connecting manholes, flushing with water after cleaning, reinstating manhole covers to their original position and disposing of sludge and other waste materials outside MoD land, complete all as specified and directed.Note: The rate quoted shall be deemed to include the cost of removal and disposal of sludge, silt and liquid materials from the sewage lines and connected manholes in the same sewer stretch. |
| 42 | Demolition of stone slabs and tiles of any description or thickness in floors complete all as specified and as directed. |
| 43 | M&L for chequered cement concrete tiles with grey cement and pigment of size 30cmX30cmX30mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 44 | M&L for chequered cement concrete tiles with grey cement and pigment of size 25cmX25cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 45 | M&L for chequered cement concrete tiles with grey cement and pigment of size 40cmX40cmX40mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 46 | M&L for machine cut kota stone slab in flooring 16-18mm thick laid over and including 15mm thick screed bed in CM 1:6 & cement mixed with pigment to match the shade of slab including rubbing and laid over and including and polishing complete all as specified and directed. |
| 47 | M&L for 60mm thick machine pressed precast concrete interlocking paver block of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and including joints filled with sand and stone dust as in levelling course of interlocking complete all as specified and directed. |
| 48 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 49 | M&L for stone walling, random rubble uncoursed, well bonded, bedded and solidly hearted, in retaining walls, abutments and similar works, built in cement mortar 1:4, complete all as specified and directed. |
| 50 | M&L in for MS steel Hollow Section work in tubular trussles, purlins, rafter, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and directed. |
| 51 | Cutting holes in RCC/brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1;2:4 type B1 complete all as specified and directed. |
| 52 | M&L for 10mm thick cement plaster in CM 1:6 on fair face of brick walls or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 53 | M&L for preparing newly plastered surfaces of walls and applying wall care putty 1 mm thick and two coats of oil bound distemper on walls complete all as specified and directed. |
| 54 | M&L for machine cut kota stone slab in flooring 18 to 20mm thick laid over and including 15mm thick screed bed in cement mortar 1:6 and pointed with cement mixed with pigment to match with the shade of slab including rubbing and polishing complete all as specified and directed. |
| 55 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 56 | M&L for 15mm thick cement plaster in CM 1:6 on fair face of brick walls or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 57 | M&L for cement concrete tiles 200 mm × 200 mm × 20 to 25 mm thick, square or rectangular, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. Please Enable Macros to View BoQ information |