| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 X 1.5 sq mm |
| 9 | 2 X 2.5 sq mm |
| 10 | 2 X 4 sq mm |
| 11 | 2 X 6 sq mm |
| 12 | 4 X 10 sq mm |
| 13 | 4 X 16 sq mm |
| 14 | 4 X 35 sq mm |
| 15 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 16 | 1 X 1.5 sq mm |
| 17 | 1 X 2.5 sq mm |
| 18 | 1 X 4 sq mm |
| 19 | 1 X 6 sq mm |
| 20 | 1 X 10 sq mm |
| 21 | 1 X 16 sq mm |
| 22 | 4 X 50 sq mm |
| 23 | Supplying and fixing of the following PVC casing capping with all accessories etc. as required. |
| 24 | 25mm x 12mm |
| 25 | 32mm x 12mm |
| 26 | Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required. |
| 27 | 19/20 mm dia |
| 28 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 29 | 5 amps power top:- |
| 30 | 3mm thick bakelite sheet |
| 31 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 32 | 1-2 module plastic switch board:- |
| 33 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 34 | 1-2 module :- |
| 35 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 36 | 6/10 amps one way SP switch (1M) :- |
| 37 | 16/20 amps one way SP switch (1M) :- |
| 38 | Bell push SP (1M) :- |
| 39 | 3 pin 6/10 amps socket outlet (2M):- |
| 40 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 41 | 4 step fan regulator (1M):- |
| 42 | Buzzer call bell (1M):- |
| 43 | Blank plate (1M):- |
| 44 | 20/25 amps single phase motor starter switch (2M):- |
| 45 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:- |
| 46 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 47 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 48 | Supplying & installation of 400 mm sweep AC padestal fan with metal blade including connection etc as required:- |
| 49 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 50 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 51 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 52 | Dismantling the existing ceiling fan and making winding by (34/35/36 S.W.G) Copper wire, varnish, oiling, greasing and re-fixing the same including wiring the down rod of standard length ( up to 30 cm ) etc. as required :- |
| 53 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required. |
| 54 | Cleaning of existing ceiling fan/luminaries. |
| 55 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 56 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 57 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 58 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 59 | 5 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 60 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 61 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 62 | 100 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):- |
| 63 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 64 | 4 way SPN MCB DB (double door):- |
| 65 | (2+10) / 12 way SPN MCB DB (double door):- |
| 66 | 4 way horizontal TPN MCB DB (Double door):- |
| 67 | 6 way horizontal TPN MCB DB (Double door):- |
| 68 | 6 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 69 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 70 | 6 to 32 amps SP MCB:- |
| 71 | 6 to 32 amps DP MCB:- |
| 72 | 40/50/63 amps TP MCB:- |
| 73 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required:- |
| 74 | 40 amps DP isolator:- |
| 75 | 40 amps FP isolator:- |
| 76 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 77 | 16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):- |
| 78 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 79 | 4 sq mm |
| 80 | 6 sq mm |
| 81 | 10 sq mm |
| 82 | 16 sq mm |
| 83 | 35 sq mm |
| 84 | 50 sq mm |
| 85 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 86 | Dismantling charges of old materials handed over to the concerned authority including ceiling fan, regulator, TL fittings, cables & other wiring materials etc. as per direction of the site engineer-in-charge L.S. Please Enable Macros to View BoQ information |