| 1 | Providing and Installation of Horizontal pump motor set (Centrifugal) with allied equipments by maintaining proper level/slope, alignment etc. in/c all necessary nuts & bolts, washers etc. at site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge. |
| 2 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 3 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: a) 1:3:6 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil- |
| 6 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level: a) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 8 | Installation of pumpset including carriage of materials from M.I store of Resource Division to site of work including trial run for 10hrs. in twospell. |
| 9 | Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm ɸ |
| 10 | Providing and fixing G.I. pipes heavy class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer- in - charge. |
| 11 | a)125 mm dia. nominal bore |
| 12 | b) 150 mm dia. nominal bore- |
| 13 | Dismentaling of G.I bend including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm ɸ |
| 14 | Excavating trenches required width for pipes, cables, etc. including excavation for sockets, collars etc and dressing of sides ramming of bottoms , depth minimum 0.90m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. and disposal of surplus excavated soil within a lead of 50m (For G.I and C.I pipes) A) All kinds of soil. i) Pipes, cables etc exceeding 75 mm dia but not exceeding 150 mm dia |
| 15 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in- Charge. |
| 16 | 150 mm dia nominal bore(medium) |
| 17 | 125 mm dia nominal bore(medium) |
| 18 | Supplying & fitting fixing of GI . bend of approved quality |
| 19 | 125 mm dia |
| 20 | 150 mm dia |
| 21 | Hiring charge of welding set of single phase with operating staff and carrying upto the site of work including loading and unloading (both way) complete as per direction of Engineer-incharge. |
| 22 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. |
| 23 | 150 mm dia |
| 24 | 125 mm dia |
| 25 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality. |
| 26 | 150 mm dia |
| 27 | 125 mm dia |
| 28 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. |
| 29 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality |
| 30 | Providing & fitting fixing MS tail piece with MS Flange suitable for pipes complete as per CPWD Specification & direction of Engineer in charge. |
| 31 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality. |
| 32 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality. |
| 33 | C.I foot valve weight |
| 34 | C.I foot valve ring |
| 35 | C.I foot valve net |
| 36 | Supplying and greasing/applying of grease in wheel bearing complete as per direction of Engineer-in-charge. |
| 37 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. |
| 38 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 Hp Osco/BCH Make |
| 39 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality. |
| 40 | Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality. |
| 41 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 42 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.7/16 Copper Wire |
| 43 | Providing and fixing MS bolts including nuts and washers complete as per standard design:-: Above 300mm length.- |
| 44 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.External work. |
| 45 | Labour charge for fitting fixing of CI sluice valve class-I with cap complete by providing nuts and bolts, 3mm thick rubber insertion etc.(Tail piece if required will be paid separately) (only C.I sluice valve class-I with will be supplied by deptt. at free of cost) |
| 46 | Providing and fitting fixing of brass fullway valve with handle in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in -charge. 40 mm dia |
| 47 | charges for fitting fixing of brass fullway valve with handle (issued from department free of cost) in the GI pipe line including cutting, threading etc. complete as per CPWD specification and direction of the Engineer - in - charge..40 mm dia |
| 48 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality. |
| 49 | 125 mm dia |
| 50 | 150 mm dia |
| 51 | Dismentling of pannel board by disconnection of all electrical equipments & stacking of materials & return the same to Sub- Divisional store as per direction of the Engineer-in-charge. |
| 52 | Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge. |
| 53 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge |
| 54 | Current range 63 Amps. |
| 55 | Current range 200 Amps Please Enable Macros to View BoQ information |