| 1 | Supplying and fixing 63 Amp. 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Havells make) (1 for D.G. incoming & 1 for Broiler farm ). |
| 2 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB,/Isolator concealed in wall after cutting the wall & mending good the damages to original finish or as per direction of E.I.C. incl. painting, connection & provision for earthing attachment .i) 4 Way ( For change over switch). |
| 3 | Supplying and fixing 63 Amp. , 415 V , 4 pole change over (MCB module)(Havells make) of on din rail of existing DBs/ enclosure and necessary connection. |
| 4 | Supplying & fixing 100 A 415V sheet metal (16 SWG) TPN Iron Clad Busbar chambers (500 mmx150 mm) on angle iron frame on wall, incl. earthing attachment and painting as required as per direction of E.I.C. {Dimension of the 4 nos Copper bar ( 100 mm long x20 mm breadth x 5 mm thick )} . |
| 5 | Supplying and fixing 415 V , 6- 32A per way , 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection incl. S & F one no 63A Four Pole MCB Isolator and 12 nos. 6 A -32 A SPMCB (‘C’ Curve, 10KA) as outgoing, oncealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment .(L & T/Havells make) . |
| 6 | S&fixing 250V, [2+10] way , 6-10A per way, SPN MCBDB with SS enclosure double door with IP-42/43 protection incl. S & fixing one no 40A DP isolator and 10 nos 6-32A SP MCB. (‘C’ Curve, 10KA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment flushed on wall as per direction of E.I.C. with all accessories. as required {Make - L&T , Enclosure (LTSD12N)}. |
| 7 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points including ceiling rose with Modular type switch (Legrand or equivalent ) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. ( Average run 5 mtr ) |
| 8 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand or equivalent ) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.(On Board) ] |
| 9 | Supplying , Laying & Erection of following sizes 1.1 KV grade XLPE insulated unarmoured Aluminium cables (Finolex/Polycab/Havells ). including supply and erection with No.6 SWG GI(Hot Dip) continuous earth wire with Galv. (Hot Dip) earth clamp (From pole to pole and fittings as per direction of E.I.C.) (For Outdoor light) ] i) 4 core 16 sq. mm. cable (Main line of Broiler farm) |
| 10 | ii) 2 core 6 sq. mm. cable |
| 11 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . i) 4 core 16 sq. mm. cable |
| 12 | ii) 2 core 6 sq. mm. cable |
| 13 | Supplying and Drawing of 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Finolex/ Polycab/ Havells) of the following sizes in PVC rigid conduit pipe incl. Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as requiredand mending good damages to building works as required.i) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC in 2x 25 mm. size PVC rigid conduit (From 63 Amp.Main Switch to B.B.C, via change over and 63 Amp Main sw. to HTPN ) |
| 14 | ii) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC in 25 mm. size PVC rigid conduit ) , (From HTPN to 2 nos. SPNIC BDB ) |
| 15 | iii) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC in 20 mm. size PVC rigid conduit ( for Multi plug point & Heater point). |
| 16 | iv) 3 x 22/0.3 (1.5 sqmm) as ECC in 20 mm size PVC rigid conduit ( for 5 A power plug only) |
| 17 | Finishing of the PVC insulated copper wire ends by Socketing with PIN /Ring type copper sockets and insulated types etc. Including supplying sockets, tapes . i) 16 Sq. mm |
| 18 | ii) 10 Sq. mm |
| 19 | iii) 6 Sq. mm |
| 20 | iv) 4 Sqmm |
| 21 | v) 2.5 Sq. mm. |
| 22 | Supplying & Fixing 40 mm dia 3.20 metre long (incl. bends) ‘L‘Type service bracket on wall for carrying 4 core 16 sq. mm cable and earth wire complete with Galv. clamp for stay, insulators etc., 7/14 SWG stranded Galv. (Hot Dip) wire for stay with 230x13 mm dia straining serews,75x88 mm porcelain shackle insulators with Galv. (Hot Dip) strips etc. and painting . |
| 23 | Supplying & Erection of Galv. ‘D’ iron complete with suitable poleclamp 100mmx114mm porcelain shackle insulator & 19 mm diaGalv. bolts & nuts. incl. painting . |
| 24 | Supplying & Fixing iron beam fan clamp of two piece type, as perapproved specification, fabricated from 40 mm x 9 mm MS sheetflat suitable for beam having flange upto 150 mm wide . |
| 25 | Supply & delivery of 1200mm (48 inch)sweep 1 phase 60/70 watt 5 star heavy duty AC ceiling fan complete with all accessories i.e. blades, down rod ,canopy, fork, rubber bush etc[ Orint Quasar/Crompton] . |
| 26 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 27 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand) on existing Modular GI switch board with top cover plate incl. Making necy. connections etc . |
| 28 | Supply only 25mm dia GI Conduit 1.6mm thick for extension of fan rod including supply and connection 3x1.5 sq. mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Finolex/Havells/Polycab) for fixing the fan below the false ceiling as per direction of E.I.C. as required. |
| 29 | Supply & Fixing of 23.0 Watt LED Lamp ,make Crompton |
| 30 | Supplying and delivery of LED Industrial Batten light made of CRCASheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection. CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate with Minimum 5 year OEM warranty. (System lumen efficacy ≥115 lm/Watt) i) Single fittings along with S/F of 1 no. 18-20 W LED lamp (4' LED tube light ) as per specification (Philips or equivalent) . |
| 31 | Fixing only fluorscent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required . |
| 32 | Supplying & Fixing 12\\" Heavy guage Aluminium conical shade ofapproved make including Supplying & Fixing pendent light fitting incl. 100 Watt B.C. lamp /incandescent lamp( Philips or equivalent make ) complete with holder incl. S & F 2x 1.5 sq. mm. copper conductor flexible cord and suspended below ceiling/beam upto 2.5 Mtr. length each from the existing ceiling rose & neccy. Connections. |
| 33 | Supply & Fixing 240 V, 2 nos 5A/10 A, 3 pin Modular type plug socket (Legrand) with 2nos 5A/10A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 34 | Supplying & Fixing 2 row 12 module GI Modular Switch Board with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall including supply and fixing 1 no. 240 V, 16 A, 3 pin Modular type plug socket ( Make - Legrand ) with 16A Modular type switch and 2 nos 240 V, 6 A, 3 pin Modular type plug socket ( Make - Legrand ) with 2 nos. 6A Modular type switch including 1 no. indicator incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire and painting and mending good damages to building works. |
| 35 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket ( Make - Legrand ) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire ( For room heater ) .. |
| 36 | Supplying, installation, Testing & Commissioning of 90 watt Street light LED fixture (Philips or equivalent )( 135 lm. per watt )powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The fixture will remain under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens as per direction of E.I.C. |
| 37 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 38 | S & F Sintex make Loop box Including 4 way connector terminal and one no. 15 Amp. Kitkat fuse fixed on insulator with proper arrangement & as per direction of EIC |
| 39 | Excavation of soil for installation of Earth Electrode and filling & ramming For Soft Soil . |
| 40 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by TATA-Medium GI pipe . |
| 41 | Supplying & fixing earth busbar of galvanized (Hot Dip)MS flat 50 mmx 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 42 | Connecting the equipments body to earth busbar including S & F 25 mm x 6mm galvanised(Hot Dip)MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts,washers etc. / welding properly as per direction of E.I.C. Please Enable Macros to View BoQ information |