| 1 | Wiring with 2 x 1.5 Sq.mm PVC insulated single core unseathed FRLS copper conductor Cable of 1100V grade in suitable PVC rigid pipe over PVC ceiling with PVC accessories and with continuous earth wire connection of 1.5 Sqmm copper wire for light point /Fan point |
| 2 | Supply and fixing of 24W LED 4000K 2 X 2 Square Type Recessed fitting with LED including cost of all materials, labour charges, lead, lift etc complete |
| 3 | Supplying and fixing of 1200mm (48”) sweep AC ceiling fan with 600mm down rod with appd best quality make of standard specification with electronic regulators and switch including cost of all materials, labour, fixing, charges as per standard specification, etc., complete. |
| 4 | Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works. |
| 5 | Distempering the Two Coats of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers. |
| 6 | Flooring with ceramic tiles of following size and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works. |
| 7 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). |
| 8 | Supplying and fixing in position best quality and approved make Indian made white /colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal /without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 9 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror of following size , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size :600 x 450 mm/500 x 400mm/1000 x 780 mm. |
| 10 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 11 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works). |
| 12 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof /floor slab and making good the dismantled portion to the original condition with kages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works) |
| 13 | Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works. |
| 14 | Supplying, laying and jointing 50mm dia PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges up to 4 metre height above ground level, etc., complete complying with standard Specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - External water supply - above ground level/Below ground level |
| 15 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 16 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 17 | Painting old iron works in glazed windows with two coat of approved enamel paint including cost of scrapping all materials, labour, leads, lifts, etc., complete. |
| 18 | Painting & lettering on the old steel Name Board including cost of all materials, scaffolding charges, labour, lead, lift, etc. complete, as directed by the Engineer in Charge. |
| 19 | Through scrapping of roof tiles and plastered surfaces on open terrace and removel of dust, green moss, algac etc., washing with soap, soda and water for preparing the surface suitable for priming with Nitobond SBR including cost of all materials, labour charges, lead, lift etc complete |
| 20 | Providing one layer of 45 GSM fibre glass mesh and one coat of Fosroc Nitobond SBR latex primer and two coats of Fosroc Brushbond RFX elastomeric polymer modified cementitious waterproofing coating over the primed surface area. including cost of all material and labour charges, lead, lift etc complete. |
| 21 | Supplying and fixing in position Tar sheet of approved make for water proofing, fixing using TAR as the bonding material be prepared by heating it to the correct working temperature and be spreaded over the roof properly and uniformly @ 1.2 kg per m2 or as specified including cost of all materials, lead, lift, labour etc complete. |
| 22 | Supplying and fixing of New PVC door with frame in the building including cost of all materials, lead, lift, transport, labour charges etc, complete as directed by Board Engineer at site. |
| 23 | Supplying and fixing of PVC false ceiling with GI section and PVC panel size of 10”x120” including GI Runner, support angle and fixing it with bolt and nut, Removal of Old existing thermocol ceiling including cost of all materials, labour charges, transportation charges, lead, lift etc complete. |
| 24 | Drilling of holes with electrically operated hammer drilling machine with 18 mm drill bit to a depth of 75 mm, fixing the 15mm dia PVC nozzle inside the hole to half the depth of the holes using Renderoc plug, quick setting compound including scrapping of leached deposits on the wall, inclusive of all materials and labour charges, scaffolding charges etc., complete. |
| 25 | Mixing of cement slurry with expandable grout admixture Cebex 100, Nitobond SBR cement modifier and potable water for pumpable consistency and pumping the slurry into the PVC nozzle using 40psi hand operated grout pump until the slurry refuses to go inside the hole, cost inclusive of cement, chemicals, labour charges, T&P’s, lead, lift etc., complete. |
| 26 | Plugging the grout nozzle immediately on refusal of slurry using Renderoc plug, quick setting compound and finishing the grout hole inclusive of cost of all materials, labour charges, lead, lift etc., complete. |
| 27 | Drilling of holes with electrically operated hammer drilling machine with 18 mm drill bit to a depth of 75 mm, fixing the 15mm dia packer nozzle inside the hole to half the depth of the holes and fixing nozzle using Renderoc plug a quick setting compound, pumping of single component hydrophobic polyurethane grout into the nozzle using high pressure grout pump until the grout material refuse to go inside the nozzle, plugging the grout nozzle immediately with Rendroc plug on refusal of slurry into the nozzle, including all scaffolding charges etc., cost of chemicals labour charges, lead, lift complete. |
| 28 | Distempering two coats with oil bound distemper to wall surface adjoining the penstock pipes including cost of all materials, labour charges, lead, lift etc., complete. Please Enable Macros to View BoQ information |