| 1 | Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. fans,E.I.,street light/compound lighting 3. water supply arrangement 4.water cooler (Electrical Point of view) 5.air coolers (Electrical Point of view) 6.LT panel maint. (Two wireman & One Khallasi on all days except Sundays, 2nd Saturday in Month and Holidays except when required) |
| 2 | Supplying following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 3 | 5/6 A switch |
| 4 | 15/16 A switch |
| 5 | 3 pin 5/6 A socket outlet |
| 6 | 6 pin 15/16 A socket outlet |
| 7 | Supplying following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 8 | 6 Module |
| 9 | Supplying 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB etc. as required. |
| 10 | Single Pole |
| 11 | Double pole |
| 12 | Triple pole and neutral |
| 13 | Supplying following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 14 | 1.5 Sq mm |
| 15 | 2.5 Sq mm |
| 16 | Supplying two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 17 | For repairing of ceiling fan/exhaust fan/wall fan |
| 18 | Capacitor (2.5µF ) |
| 19 | Bearing of fan |
| 20 | Rewinding of fan |
| 21 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm) i) 36 watt |
| 22 | LED Batten light (System lumen efficacy ≥105 <120lm/Watt).Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), DCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness >0.50 mm)i) 18-22 Watt |
| 23 | Supply of PVC insulated and PVC sheathed power cable of 1.1 KV grade armoured aluminium conductor cable confirming to IS code with up to date amendment of follwing size etc. as required of make of reputed brand under MII confirming to IS and IEC codes |
| 24 | a) 2 X 10 Sq mm |
| 25 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 26 | 100 Watt |
| 27 | 200 Watt |
| 28 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim i) 18 Watt |
| 29 | Supply of Exhaust fan alongwith louvers with sweep size of 250 mm, RPM 1200, 220-240 V and with air delivery capacity > 800 CMH confirming to IS and IEC code as approved by the Engineer in charge. |
| 30 | Lifting & lowring the existing monoblock openwell submersible water pump along with pipe line from open well / underground tank including G.I./PVC Pipe Line, Valves etc as required. |
| 31 | Rewinding of submersible / monoblock / monosubmersible water pump including credit the damage wire. |
| 32 | Replacement of required accessories i.e. bearing, bush, impillars etc. of monoblock / monosub motor pump set. |
| 33 | Providing, Installation, Testing and Commissioning of verticle type SS body submersible pump suitable for working on 3 phase, 415 volts, 50 Hz having no. of stages - 38 , HP/kW - 5/3.7,Head - 10-296 m Delivery Size - 38 mm (1.5\\"), Speed - 2800 RPM, Min.- Max. Discharge -15 - 90 lpm complete with installation of pump set along with existing GI pipes, modifications in pipe laying, etc. upto 300 feet as required. |
| 34 | Supply and laying of 40 mm dia heavy duty CPVC column pipes for submersible pump with leakproof , watertight joints, corrosion resistant property complete with all aceessories (couplers, elbow, union, reducer,ball valve, etc) |
| 35 | Supply and fixing of 630 A, 415 V operational voltage, 50 Hz , 4 Way, weatherproof, outdoor,wall mounting type Busbar Chamber with angle stand and suitable for connection of 3 phase, 4 Core Aluminium Armoured Cables as required having removable gland plate with knock out provision and Liberal space between cable / busbar and live parts, fabricated using sheet steel (CRCA) and epoxy powder coated to give superior & lasting finish, manufactured by CPRI approved manufacturer. |
| 36 | Providing of 400 mm sweep size Pedestal Fan with rated voltage 230 V, 50 Hz, 100% copper motor, with oscillation function, protection of motor against thermal overload, air delievery > 140 cubic meter/minute with speed control function with minimum warranty of 2 years as approved by the Engineer in charge. |
| 37 | Providing of 220-240 V, 50 Hz, 400 mm sweep size Wall fan in white colour having motor speed with more than 1250 RPM, air delivery capacity of more than 65 m³/min, having minimum power input and with thermal overload protection as approved by the Engineer in charge. |
| 38 | Credit Items : |
| 39 | Old Pll Light along with its fixture |
| 40 | Old GI pipe Please Enable Macros to View BoQ information |